Introduction
Aircraft batteries are more than emergency containers of stored electricity. They provide an independent source of electrical energy, support engine or APU starting on many aircraft, stabilise the electrical system during transients and supply selected services when normal generation is unavailable. Batteries also depend on the same electromagnetic principles that make electric motors and generators work.
This chapter develops three connected subjects: electrochemical energy storage, magnetic fields and electromagnetic induction, and the operation of direct-current machines. The aim is to understand not only what each component does, but why it behaves as it does and how that behaviour appears in aircraft operation.
Learning objectives
- Explain the construction, chemical action and electrical characteristics of aircraft batteries.
- Compare lead-acid, nickel-cadmium and lithium-based battery technologies at a general level.
- Interpret voltage, ampere-hour capacity, state of charge, discharge rate and battery condition.
- Describe magnetic fields, flux, field strength, permeability and the effect of current in a conductor.
- Explain electromagnetic induction, Lenz's law, force on a current-carrying conductor and torque production.
- Describe the construction and operation of a DC motor and a DC generator.
- Explain commutation, brushes, back EMF, field windings and the principal DC machine types.
- Describe how a starter-generator changes between motor and generator modes.
- Recognise battery and DC machine hazards, abnormal indications and maintenance considerations.
1. Battery fundamentals and electrochemical action
A battery is an electrochemical device that stores energy in chemical form and releases it as electrical energy when connected to a suitable external circuit. A battery is made from one or more electrochemical cells connected in series, parallel or a combination of both. The cell is the basic unit; the battery is the assembled source.
1.1 The basic cell
A typical cell contains two electrodes of different electrochemical characteristics and an electrolyte that permits ionic movement between them. During discharge, chemical reactions at the electrodes create a potential difference. Electrons travel through the external circuit from the negative terminal towards the positive terminal, while ions move within the cell to maintain charge balance.
The electrode at which oxidation occurs. It releases electrons into the external circuit and is the negative electrode in a discharging galvanic cell.
The electrode at which reduction occurs. It accepts electrons from the external circuit and is the positive electrode in a discharging galvanic cell.
Electrode names are defined by the reaction occurring, not simply by a permanent positive or negative label. In rechargeable cells the reactions reverse during charging, so the chemistry and the manufacturer's terminology must be followed carefully.
1.2 Cell voltage and battery voltage
The voltage of a cell is determined primarily by its chemistry and condition. Connecting cells in series adds their voltages. Connecting cells in parallel increases the available capacity and current capability while retaining approximately the voltage of one cell.
| Connection | Effect on voltage | Effect on capacity |
|---|---|---|
| Series | Cell voltages add | Ampere-hour capacity remains approximately that of one cell |
| Parallel | Voltage remains approximately that of one cell | Capacities add, if cells are compatible and correctly matched |
For example, twenty 1.2 V nickel-cadmium cells connected in series produce a nominal battery voltage of approximately 24 V. The actual terminal voltage varies with state of charge, current, temperature and cell condition.
2. Aircraft battery technologies
Aircraft battery selection is a design decision involving mass, energy capacity, power delivery, temperature performance, charging characteristics, maintenance, service life, containment and certification. No chemistry is universally best.
2.1 Lead-acid batteries
A lead-acid cell uses a lead-based negative plate, a lead dioxide positive plate and a sulphuric-acid electrolyte. During discharge, both plates are progressively converted towards lead sulphate and the electrolyte becomes less concentrated. Charging reverses the chemical process.
2.2 Nickel-cadmium (NiCd) batteries
Nickel-cadmium cells use a nickel-based positive electrode, a cadmium-based negative electrode and potassium hydroxide electrolyte. Their nominal cell voltage is approximately 1.2 V. Aircraft batteries commonly use a number of cells connected in series to obtain the required system voltage.

2.3 Lithium-based batteries
Lithium-based aircraft batteries offer high energy density and can reduce mass. Different lithium chemistries have different characteristics; “lithium battery” is not one single design. Aircraft installations require carefully engineered battery management, cell monitoring, thermal control, containment and protection against overcharge, over-discharge, short circuit and excessive temperature.
Thermal runaway is a serious failure mode in which an internal reaction generates heat faster than it can be dissipated. The heat can trigger further reactions and propagate to adjacent cells. Aircraft design and maintenance controls therefore include approved charging equipment, monitoring, installation requirements and specific emergency procedures.
| Feature | Lead-acid | NiCd | Lithium-based |
|---|---|---|---|
| Nominal cell voltage (typical) | About 2.0 V | About 1.2 V | Varies by chemistry; commonly around 3–4 V |
| Mass / energy density | Relatively low | Moderate | Generally high |
| Key concerns | Ventilation, acid, sulphation | Thermal runaway, electrolyte, cadmium handling | Thermal runaway, monitoring and approved charging |
| Maintenance | Type-specific electrolyte and condition checks | Cell condition and approved servicing | System monitoring and manufacturer-specific procedures |
3. Battery ratings, capacity and performance
3.1 Ampere-hour capacity
Battery capacity is commonly expressed in ampere-hours (Ah). It is a measure of the quantity of charge a battery can deliver under specified test conditions. A nominal 20 Ah battery might, under its stated test conditions, deliver 2 A for 10 hours. This is an illustrative arithmetic relationship, not a guarantee that every battery will deliver that exact combination in service.
Rearranging gives time = capacity ÷ current. A 24 Ah battery supplying a steady 3 A load would have an idealised duration of 8 hours. Actual endurance is reduced by discharge-rate effects, temperature, battery age, condition, voltage limits and reserve requirements.
3.2 Energy and power
A 24 V, 20 Ah battery has a nominal energy calculation of 480 Wh. This is a theoretical rating calculation. The usable energy available to an aircraft load will be lower and must be established using approved performance data and the aircraft's minimum operating voltage.
3.3 State of charge, state of health and internal resistance
A battery can show a plausible open-circuit voltage yet fail under load because its internal resistance has increased or its usable capacity has deteriorated. This is why voltage alone is not a complete measure of battery condition.
3.4 Discharge rate and temperature
Capacity ratings are established at specified discharge rates and temperatures. A high current demand can reduce the effective capacity available compared with a slower discharge. Low temperature can reduce chemical reaction rates and available output. High temperature can accelerate ageing and, depending on chemistry and charging conditions, increase the risk of damage.
4. Magnetism and magnetic fields
Magnetism is central to electric motors, generators, relays, contactors, sensors and many instruments. A magnetic field is a region in which magnetic forces can act. It is commonly represented by magnetic field lines: outside a bar magnet, the conventional direction is from north to south.
4.1 Magnetic poles and field lines
Like poles repel and unlike poles attract. Magnetic field lines form continuous loops; they do not begin or end in free space. A stronger magnetic field is represented by more closely spaced field lines. The field direction at a point is the direction a north-seeking pole would tend to move.
4.2 Magnetic materials and permeability
Materials such as iron and certain alloys can concentrate magnetic flux because they have high magnetic permeability. A soft-iron core inside a coil can greatly strengthen the magnetic field for a given current. This principle is used in electromagnets, relays, motors and generators.
4.3 Magnetic flux and flux density
Magnetic flux (Φ) describes the total magnetic field passing through a surface and is measured in webers (Wb). Magnetic flux density (B) is flux per unit area when the field is uniform and perpendicular to the area, measured in teslas (T).
where B is flux density in teslas, Φ is flux in webers and A is area in square metres. For a uniform field, reducing the area through which a fixed flux passes increases the flux density.
5. Electromagnetism and electromagnetic induction
5.1 Current produces a magnetic field
When electric current flows through a conductor, a magnetic field forms around it. The field direction can be found using the right-hand grip rule: point the right thumb in the direction of conventional current and the curled fingers show the direction of the magnetic field around the conductor.
Winding the conductor into a coil causes the fields from individual turns to reinforce one another. Inserting a suitable ferromagnetic core increases the field strength. This is the basis of an electromagnet.
5.2 Force on a current-carrying conductor
A conductor carrying current in a magnetic field experiences a force when the current direction is not parallel to the magnetic field. The direction is determined by the motor rule (often taught using Fleming's left hand): field, current and force are mutually perpendicular.
For a straight conductor at right angles to a uniform field, force is proportional to magnetic flux density, current and active conductor length:
This relationship explains how a motor develops force. In a rotating machine, conductors on opposite sides of an armature experience forces in opposite directions, producing a turning effect (torque).
5.3 Electromagnetic induction
When a conductor cuts magnetic flux, or when the magnetic flux linking a coil changes, an electromotive force (EMF) is induced. The magnitude depends on the rate of change of flux linkage. Increasing the field strength, the number of turns or the rate of relative movement generally increases induced EMF.
The minus sign represents Lenz's law: the induced EMF acts in a direction that opposes the change producing it. This is a statement of energy conservation. A generator therefore requires mechanical work to maintain rotation while delivering electrical power to a load.
6. Direct-current motors
A DC motor converts electrical energy into mechanical energy. Its main parts are a stator field system, a rotating armature, a commutator, brushes, bearings and a supporting frame. Depending on design, the magnetic field may be produced by permanent magnets or field windings.
6.1 Main components
6.2 How a DC motor develops torque
- DC is applied to the motor through its brushes and commutator.
- Current flows in the armature conductors while they are within the stator magnetic field.
- Magnetic forces act on the conductors. Forces on opposite sides of the armature form a couple.
- The resulting torque rotates the armature and shaft.
- As the armature rotates, the commutator reverses current in each coil at the correct position, maintaining torque in the same rotational direction.
6.3 Back EMF
As the armature rotates in the magnetic field, it also acts as a generator. The induced voltage opposes the applied supply voltage; this is called back EMF. At start, the motor is stationary, so back EMF is approximately zero. Armature current can therefore be very high and is limited mainly by winding resistance and the rest of the circuit.
where V is applied voltage, Eᵦ is back EMF and Rₐ is armature-circuit resistance. As speed rises, back EMF increases and armature current normally falls. This is why a starter motor draws a very high current initially, with current reducing as the engine accelerates.
6.4 DC motor types
| Type | Field connection | General characteristic |
|---|---|---|
| Series-wound | Field winding in series with armature | High starting torque; speed can rise dangerously with little load, so it must not be operated unloaded unless designed and controlled for that condition. |
| Shunt-wound | Field winding in parallel with armature | Relatively stable speed with changing load. |
| Compound-wound | Combination of series and shunt field windings | Combines useful starting torque with improved speed characteristics. |
7. Direct-current generators
A DC generator converts mechanical energy into electrical energy. A prime mover rotates the armature or magnetic field, causing conductors to cut magnetic flux and develop an induced EMF. The commutator converts the internally generated alternating voltage in the rotating armature coils into a unidirectional output at the brushes.
7.1 Generator construction and operation
The basic components resemble those of a brushed DC motor: field system, armature, commutator, brushes, shaft and bearings. The machine is driven mechanically, commonly through an engine accessory gearbox on older or specialised aircraft installations.
- A prime mover turns the generator shaft.
- Armature conductors rotate through the magnetic field.
- Changing flux linkage induces EMF in the conductors.
- The commutator and brushes provide a DC output to the external circuit.
- When a load is connected, current flows and electromagnetic reaction creates an opposing torque; the prime mover must supply additional mechanical power.
7.2 Commutator and brushes
The EMF induced in an individual rotating armature coil reverses direction every half-turn. The commutator changes the coil's connection to the external circuit at the same time, so the polarity at the brushes remains unidirectional. The output is pulsating DC; multiple armature coils and commutator segments make the output smoother.
7.3 Field excitation and regulation
The magnetic field may be provided by permanent magnets or field windings. In a wound-field generator, field current controls magnetic flux and therefore influences generated voltage. A voltage regulator adjusts field excitation to maintain the required system voltage as engine speed and electrical load vary.
Generator output is not determined by speed alone. It also depends on field strength, load, internal voltage drops, temperature and the regulation system. Aircraft-specific control units may also provide protection, current limiting, fault detection and connection/disconnection logic.
7.4 Armature reaction and commutation issues
Armature current produces its own magnetic field. This field can distort or weaken the main field, a phenomenon known as armature reaction. Poor commutation may produce sparking at the brushes, heat, wear and reduced efficiency. Interpoles or compensating windings may be used in some machine designs to improve commutation.
8. Starter-generators and aircraft applications
Some turbine-powered aircraft use a starter-generator: one DC machine performs two functions. During engine starting it operates as a motor, drawing high current from the battery or an approved external source. Once the engine reaches the required speed and the system changes configuration, the same machine operates as a generator and supplies electrical power.
8.1 Starting mode
- The start command energises the approved control and relay circuits.
- Motor torque accelerates the engine through the accessory gearbox.
- As engine speed rises, the motor's back EMF increases and current normally decreases.
- At the designed cut-out or transition condition, the starter circuit is disconnected or reconfigured.
8.2 Generating mode
- The machine is driven by the engine through the gearbox.
- Field excitation is established and controlled.
- When output reaches the required conditions, the generator is connected to the aircraft DC distribution system.
- The unit supplies electrical loads and may recharge the battery, subject to the aircraft's control and protection logic.
8.3 Advantages and limitations
- One machine performs two functions.
- Can reduce component count, mass and installation complexity.
- Uses a common mechanical drive installation.
- Requires switching and control logic to change modes.
- High starting current creates significant electrical and thermal demands.
- Output capability depends on engine speed and machine design.
Not every aircraft uses a DC starter-generator. Many modern aircraft use AC starter-generators, integrated drive generators, permanent-magnet generators, separate starters or air-turbine starters. Always identify the architecture from the aircraft documentation rather than assuming a system based on engine type alone.
9. Common faults, indications and maintenance considerations
9.1 Battery-related symptoms
| Symptom | Possible causes | Why it matters |
|---|---|---|
| Low voltage under load | Low state of charge, high internal resistance, weak cell, poor terminal connection | Loads may drop offline or equipment may malfunction. |
| Slow or unsuccessful starting | Insufficient battery capacity, high resistance in cables or connections, starter fault, unsuitable temperature | Starting performance depends on both source capability and circuit integrity. |
| Unusual heating or odour | Abnormal charging, internal fault, excessive current or damaged connection | May indicate a fire, venting or thermal event risk. |
| Corrosion or electrolyte evidence | Leakage, venting, unsuitable servicing or environmental damage | Can damage structure, wiring and adjacent equipment. |
9.2 DC machine-related symptoms
9.3 Inspection and safety principles
Aircraft battery and DC machine maintenance is type-specific. General principles include checking security, condition, connectors, cable support, evidence of overheating, corrosion, leakage, ventilation and abnormal mechanical condition. Electrical isolation, protective equipment, ventilation, fire precautions and approved tooling must be considered before maintenance.
10. Worked examples and operational applications
Example 1 — Series-connected cells
A battery contains 20 NiCd cells, each with a nominal voltage of 1.2 V, connected in series.
The series connection adds cell voltages. It does not multiply the Ah capacity by 20.
Example 2 — Battery energy estimate
A nominal 24 V, 18 Ah battery is being considered for a theoretical energy calculation.
This is a nominal calculation only. It is not a dispatch endurance figure and does not account for discharge rate, temperature, ageing, reserve or minimum voltage.
Example 3 — Approximate load duration
A 30 Ah battery supplies a constant 5 A load in an idealised calculation.
Actual operating duration will be lower or otherwise different depending on the manufacturer's discharge characteristics and system cut-off limits.
Example 4 — Electrical load current
A 24 V DC load consumes 480 W.
The supply and wiring must be designed for the required current and installation conditions. The circuit protection rating is not selected from this arithmetic alone.
Example 5 — Motor starting current
A simplified motor has a 24 V supply and an armature resistance of 0.08 Ω. At the instant before rotation, back EMF is approximately zero.
This explains why starter circuits require heavy conductors, robust contactors and carefully engineered protection. The actual starting current depends on the motor design, battery voltage and complete circuit resistance.
Example 6 — Current after the motor accelerates
If the motor develops 18 V of back EMF while the supply remains 24 V, with the same simplified 0.08 Ω armature resistance:
As speed rises, back EMF increases and current decreases. This is a central feature of DC motor starting behaviour.
Example 7 — Force on a conductor
A 0.20 m conductor carries 8 A at right angles to a uniform 0.5 T magnetic field.
The conductor experiences a force of 0.8 N in the direction determined by the motor rule.
Example 8 — Flux density
A magnetic flux of 0.006 Wb is uniformly distributed across an area of 0.003 m².
The flux density is 2 teslas under the stated idealised assumptions.
Example 9 — Starter-generator energy conversion
During start, the battery supplies electrical energy and the machine produces shaft torque. After transition, the engine supplies shaft power and the machine delivers electrical power to the DC system. The hardware is similar, but the direction of energy conversion reverses.
Example 10 — Fault isolation logic
If a battery voltage appears normal with no load but collapses during engine start, consider battery internal resistance, terminal and cable resistance, contactor condition and starter demand. A single open-circuit voltage reading cannot identify which item is faulty. Use the approved fault-isolation procedure and specified measurements.
11. Battery chemistry in greater depth
11.1 Lead-acid discharge and charge reactions
In a conventional lead-acid cell, the positive plate is lead dioxide (PbO₂), the negative plate is spongy lead (Pb), and the electrolyte is sulphuric acid (H₂SO₄). During discharge, both active plate materials are converted towards lead sulphate (PbSO₄), while water is formed and the electrolyte becomes less concentrated. During charging, an external DC source drives the reaction in the reverse direction.
This equation is a simplified overall reaction. The practical cell also involves porous active materials, separators, current collectors, gas evolution and temperature-dependent reaction rates.
11.2 Nickel-cadmium discharge and charge reactions
In a NiCd cell, the positive active material is nickel oxyhydroxide in the charged state and the negative active material is cadmium. During discharge, the positive electrode is reduced and the cadmium electrode is oxidised; potassium hydroxide acts as the electrolyte and supports ionic conduction. Unlike a lead-acid cell, the electrolyte concentration is not a reliable state-of-charge indicator for a NiCd battery.
NiCd cells are known for their ability to deliver high current and for a relatively flat discharge-voltage profile over much of their useful discharge. This can be helpful for high-power starting demands, but it also means a voltage reading may not reveal the remaining capacity as clearly as a learner might expect.
11.3 Why battery chemistry matters to the aircraft
- Charging voltage and current limits depend on chemistry and battery design.
- Ventilation requirements depend on the gases that can be produced during charging or abnormal operation.
- Electrolyte hazards differ: sulphuric acid is acidic, while potassium hydroxide is strongly alkaline.
- Cell balancing, thermal monitoring and battery management requirements differ.
- A replacement battery must be approved for the installation; matching voltage and physical dimensions is not enough.
12. Charging, temperature and battery thermal behaviour
12.1 Charging is controlled energy transfer
Charging is not simply applying a voltage to a battery. The charging source must be compatible with the chemistry, cell count, temperature range, battery condition and approved aircraft installation. Depending on the battery type, the design may use constant-voltage, constant-current, staged or electronically managed charging. A modern battery management system may monitor individual cell voltages and temperatures and control contactors or charging limits.
When an aircraft generator is online, it normally supplies the aircraft loads and maintains the battery charge through the regulated electrical system. The generator must have sufficient capacity for both the operating loads and the battery's charging demand. A deeply discharged battery can impose a substantial recharge load.
12.2 Thermal runaway in NiCd batteries
Thermal runaway is a positive-feedback condition. As a NiCd battery heats, its effective internal resistance can fall. With a constant-voltage charging source, the battery may then draw more current. The increased current creates additional heat, which can further reduce resistance and increase current. Without effective detection and control, temperature can rise rapidly.
12.3 Temperature effects
Low temperature generally reduces the rate of electrochemical reactions and can reduce the current or capacity available for starting. High temperature may temporarily improve some discharge characteristics but accelerates ageing and can make charging more hazardous. Temperature correction and performance limits must come from the battery manufacturer's data.
12.4 Charging and maintenance traps
- Do not assume one charger profile is suitable for all battery chemistries.
- Do not infer NiCd state of charge from electrolyte specific gravity; approved test methods are required.
- Do not ignore generator capacity when considering battery recharge after repeated starts.
- Do not continue operating a battery that shows abnormal heat, swelling, leakage, venting or damaged connections.
13. DC generator design, output and control
13.1 Main construction details
The armature normally consists of a shaft, a laminated soft-iron core, insulated windings and a commutator. The field assembly provides magnetic poles and field windings. Brushes contact the commutator and transfer current to the external circuit. Bearings support the shaft, while the frame provides mechanical support and a magnetic return path.
13.2 Why the armature core is laminated
A changing magnetic field in a solid iron core can induce circulating currents within the core itself. These are called eddy currents and they produce unwanted heating and energy loss. Building the core from thin insulated laminations interrupts the paths available to these currents and reduces their magnitude. The laminations are aligned to preserve the desired magnetic path while limiting electrical circulation within the core.
13.3 Generated EMF and speed
For a given generator design, generated EMF is proportional to magnetic flux per pole and rotational speed, with the number of conductors and parallel paths also affecting the relationship.
Here Φ is magnetic flux per pole and N is rotational speed. This proportional relationship is a useful principle, not a substitute for the generator's rated output curve. A voltage regulator adjusts field current to compensate for changing speed and load within the machine's operating limits.
13.4 Shunt, series and compound generators
| Generator type | Field arrangement | General behaviour |
|---|---|---|
| Separately excited | Field current can be controlled independently of armature output. | |
| Shunt-wound | Field winding connected in parallel with armature output | Commonly associated with relatively stable voltage characteristics over a designed operating range. |
| Series-wound | Field winding in series with load current | Field strength varies with load current; not generally used where a stable aircraft bus voltage is required without additional control. |
| Compound-wound | Combination of shunt and series fields | Can be designed to improve voltage regulation as load changes. |
13.5 Generator control functions
A generator control system can perform several functions: voltage regulation, current limiting, reverse-current protection, generator connection and disconnection, and fault indication. Older DC systems may use electromechanical relays; modern installations use solid-state control units and electronic monitoring.
14. Commutation, armature reaction and machine losses
14.1 Commutation in practical terms
The commutator is divided into insulated copper segments. Each armature coil is connected to appropriate segments. As the armature rotates, brushes remain in contact with the commutator surface. At the neutral position, the brush bridges or transfers between segments so the current in the relevant coil reverses. This timed reversal maintains a useful unidirectional torque in a motor and a unidirectional external output in a generator.
Brushes are consumable contact components. Brush pressure, surface condition, commutator cleanliness, alignment and the machine's electrical loading all influence reliable operation. Excessive sparking is a symptom requiring investigation, not a condition to ignore.
14.2 Armature reaction
When load current flows in the armature, it creates a magnetic field of its own. This armature field interacts with the main field and can distort the magnetic neutral plane. The result may be poorer commutation, sparking and a change in generated voltage. Some machines use interpoles, also called commutating poles, to improve the magnetic conditions where the brushes transfer current.
14.3 Electrical and mechanical losses
Efficiency is the ratio of useful output power to input power. A motor's useful output is mechanical; a generator's useful output is electrical.
15. How batteries and DC machines fit into an aircraft electrical system
The battery and generator are not isolated components. They connect to a wider architecture containing buses, contactors, circuit protection, switching, monitoring and electrical loads. The precise arrangement differs significantly between aircraft.
In a typical small aircraft, the battery may supply the starter and provide limited reserve power. Once the engine-driven alternator or generator is operating, it supplies the electrical loads and maintains battery charge. Turboprop aircraft may use starter-generators, while other aircraft use separate starter and generating equipment. Some systems convert DC to AC for selected loads using an inverter.
The FAA's Pilot's Handbook of Aeronautical Knowledge includes a representative aircraft electrical-system schematic showing a battery, alternator, starter, buses, circuit protection and electrical loads. It is useful for understanding how the individual components fit into the whole system, but it should not be treated as a universal aircraft wiring diagram.
16. Additional worked examples and applied scenarios
Example 11 — Parallel battery capacity
Two compatible 24 V, 15 Ah battery units are connected in parallel in a designed system.
Nominal voltage remains approximately 24 V. Parallel connection requires compatible batteries and an approved design; it is not a field modification.
Example 12 — Voltage drop due to internal resistance
A battery has an open-circuit voltage of 25.2 V and an effective internal resistance of 0.025 Ω. It supplies 80 A in a simplified model.
This demonstrates why internal resistance becomes important during high-current starting.
Example 13 — Battery recharge load
An illustrative charging current of 12 A at 28 V represents:
The generator must support this charging demand in addition to the aircraft's operating loads, within its rating and the aircraft's control logic.
Example 14 — Generator output power
A generator delivers 28 V at 60 A.
This is electrical output power at the stated operating point. The mechanical input power must be higher because the generator is not 100% efficient.
Example 15 — Generator efficiency
A generator receives 2.0 kW of mechanical input and delivers 1.6 kW of electrical output.
The remaining 0.4 kW is associated with losses such as winding heating, core losses, friction and ventilation.
Example 16 — Conductor force
A conductor of active length 0.15 m carries 12 A at right angles to a 0.8 T field.
The force direction is determined by the motor rule. In a practical armature, many conductors contribute to total torque.
Example 17 — Induced EMF and rate of change
A 200-turn coil experiences an average flux change of 0.004 Wb per turn over 0.02 s.
The induced EMF magnitude is 40 V. Its polarity depends on the direction of the flux change, as described by Lenz's law.
Example 18 — Load endurance with reserve
A theoretical 24 Ah battery supplies a 2 A essential load. Ideal arithmetic gives 12 hours, but the aircraft-approved usable capacity is only 60% of the nominal figure under the stated conditions.
Even this is not an approved endurance figure. Actual planning must use approved discharge curves, operating limits, temperature and required reserve.
Scenario 19 — Repeated short flights
An aircraft performs several short sectors with repeated engine starts and little time for the generator to restore the battery's charge. The battery may progressively lose state of charge, even though the generator appears normal during each flight. Consider duty cycle, recharge time, battery condition and the approved operating procedure.
Scenario 20 — Generator failure after take-off
If the generator disconnects, the battery may become the remaining source for selected DC buses. The endurance depends on battery condition, electrical load shedding, bus architecture and the aircraft's emergency procedure. The pilot follows the aircraft checklist; the technician later uses approved fault-isolation data.
Scenario 21 — Hot battery compartment
A battery compartment is unusually hot after repeated starting attempts. This should not be dismissed as normal. Possible contributors include prolonged cranking, high charging voltage, poor cell connections, ventilation problems or internal battery faults. Stop and follow the aircraft's abnormal procedure and maintenance instructions.
Scenario 22 — Brush sparking
A DC generator shows excessive brush sparking. Possible causes include worn brushes, incorrect brush seating or pressure, commutator contamination or damage, overload, or poor commutation. The symptom alone does not identify the failed component; inspection and tests must follow the component manual.
Chapter summary and revision checklist
- A battery stores energy chemically and converts it into electrical energy during discharge.
- Lead-acid discharge converts both active plate materials towards lead sulphate; prolonged discharged storage can cause damaging sulphation.
- NiCd electrolyte concentration is not a dependable state-of-charge measurement; approved battery-specific tests are required.
- NiCd thermal runaway can develop through a feedback loop involving temperature, falling internal resistance and rising charging current.
- Charging demand is part of generator loading; the source must supply aircraft loads and battery recharge within its rating.
- Generator cores are laminated to reduce eddy-current losses; armature reaction can distort the main magnetic field and affect commutation.
- DC generator control may include voltage regulation, current limiting, reverse-current and overvoltage protection.
- Battery, generator, buses, contactors and loads form one integrated electrical architecture; a component must be understood in its system context.
- A cell is the basic electrochemical unit; a battery contains one or more interconnected cells.
- Series connection adds voltage; parallel connection increases capacity and current capability when correctly designed.
- Lead-acid, NiCd and lithium-based batteries have different voltage, mass, maintenance and safety characteristics.
- Ampere-hour capacity is charge delivery under specified conditions, not a guaranteed endurance figure.
- State of charge and state of health are different. A battery can have acceptable open-circuit voltage but poor performance under load.
- Current produces a magnetic field; a coil and suitable core form an electromagnet.
- A current-carrying conductor in a magnetic field experiences force. This is the basis of motor torque.
- Changing magnetic flux linkage induces EMF. Lenz's law describes the opposing direction of the induced effect.
- A DC motor converts electrical energy into mechanical energy. Back EMF increases with speed and limits armature current.
- A DC generator converts mechanical energy into electrical energy. The commutator and brushes provide a unidirectional external output.
- A starter-generator operates as a motor during starting and as a generator after transition to the running mode.
- Battery and DC machine maintenance must follow the aircraft maintenance manual and component instructions.
Before moving on, make sure you can:
- Explain why a 24 V NiCd battery may contain 20 cells in series.
- Calculate Ah capacity, approximate energy and simple load current.
- Explain why a starter motor draws high current at standstill.
- Distinguish motor action from generator action.
- Describe the role of the commutator and brushes.
- Explain the operating-mode change in a starter-generator.
Knowledge check — 12 questions
Select one answer for each question, then submit to see your score and explanations. These questions test understanding, not aircraft-specific maintenance procedures.
1. What is the approximate nominal voltage of a nickel-cadmium cell?
2. What is the main electrical effect of connecting identical cells in series?
3. A battery capacity rating in ampere-hours is a measure of:
4. Why might a battery show acceptable open-circuit voltage but fail during starting?
5. What is the conventional direction of magnetic field lines outside a bar magnet?
6. Which principle is directly responsible for force on a motor armature conductor?
7. What does Lenz's law describe?
8. Why is DC motor current very high at the instant of starting?
9. What is the principal function of the commutator in a brushed DC motor?
10. A DC generator primarily converts:
11. In a typical DC starter-generator installation, what happens after the engine reaches the required transition condition?
12. Why must battery terminals be protected against accidental short circuit?
Further study
- Aircraft manufacturer maintenance manuals, battery component maintenance manuals and approved training material for the specific aircraft type.