Introduction

Why rotational speed matters

This chapter moves from the physical measurement of shaft speed to the coordination of multi-engine propellers. The central idea is that an instrument does not measure “engine performance” in general: it senses a particular rotating assembly, converts that movement into a signal, and presents a calibrated indication to the crew. Understanding each stage helps pilots interpret readings correctly and helps maintenance personnel reason about possible faults.

Engine speed is one of the primary parameters used to assess and control powerplant operation. On a piston engine, the tachometer normally indicates crankshaft speed in revolutions per minute (RPM). On a gas turbine, speed indication usually relates to one or more compressor or spool assemblies and may be displayed as a percentage of a defined reference speed. The exact shaft measured depends on engine architecture.

On multi-engine aircraft, the crew may also need to compare propeller speeds. A synchronising system reduces differences between propeller RPM, while a synchrophasing system additionally controls the relative angular position of the blades to reduce objectionable beat or cabin noise. These functions are related but not identical.

MeasureConvert shaft rotation into a readable RPM or percentage indication.
CompareIdentify differences between engines or between engine and rotor speeds.
CoordinateReduce propeller speed differences and, where fitted, blade-phase noise.
Learning outcomes

By the end of this chapter, you should be able to:

1 · Fundamentals

What does a tachometer measure?

A tachometer measures rotational speed. One revolution is one complete 360° turn of a shaft. RPM is the number of revolutions completed in one minute. A tachometer is therefore a speed instrument, not a direct measurement of thrust, torque, power or propeller blade angle.

For a piston engine, the instrument normally senses crankshaft speed. For a turbine engine, the measured shaft may be the low-pressure compressor (N1), high-pressure compressor (N2), power turbine or another spool depending on the design. A free-power-turbine turboprop can have separate gas-generator and propeller-shaft speed indications.

RPM versus percentage RPM: A piston-engine tachometer is commonly calibrated in RPM. Turbine instruments frequently show percentage of a defined reference speed. A display of 100% does not mean 100 RPM; it means the shaft is at its specified reference speed.

Basic relationship

RPM = (rotations per second) × 60

Where a toothed wheel or target produces a known number of pulses per revolution, the processor can calculate speed from pulse frequency:

RPM = (pulse frequency × 60) ÷ pulses per revolution

For a multi-spool turbine, each spool requires an appropriate sensing and processing channel. N1 and N2 are not interchangeable: they refer to different rotating assemblies and can operate at different speeds.

Reading the scale and understanding reference speed

An analogue tachometer may use a scale marked in hundreds of RPM, thousands of RPM, or percentage of reference speed. The pilot must read the scale multiplier and units before interpreting the pointer. For example, a pointer at 24 on a scale marked “RPM × 100” represents 2,400 RPM, not 24 RPM. A digital display removes the multiplier-reading step but does not remove the need to understand units and operating limitations.

On a turbine engine, percentage RPM is calculated against a defined reference speed for the particular rotating assembly. It allows a standardised presentation across engines whose actual shaft speeds differ. The reference is not necessarily the same for N1, N2 and N3, and a displayed percentage should never be transferred from one engine type to another without its documentation.

Drive ratio and calibration

The sensing unit may not rotate at the same speed as the engine shaft. Accessory gearing can increase or reduce the speed delivered to a tachometer drive. The instrument calibration accounts for this ratio. If a gear train is changed, incorrectly installed or mismatched to the indicator, the pointer can be consistently wrong even though the sensing mechanism is functioning.

Worked scale example: An analogue dial is marked RPM × 100 and the pointer indicates 27.5. The indicated speed is 27.5 × 100 = 2,750 RPM. Always verify the dial multiplier and the aircraft's approved operating range.
2 · Magnetic-drag tachometer

Mechanical magnetic-drag indication

This design is associated mainly with older piston-engine installations. A flexible drive cable, driven by the engine accessory gearing, rotates a permanent magnet inside the instrument. The rotating magnetic field induces eddy currents in a surrounding conductive drag cup, commonly aluminium. The eddy currents create a magnetic field that interacts with the rotating magnet's field, producing a torque that tends to turn the cup.

The cup is connected to the pointer shaft. A hairspring opposes the turning torque. At a steady speed, the magnetic torque and spring torque reach equilibrium; the pointer settles at a position corresponding to RPM. A gear ratio and calibrated dial allow the instrument to indicate engine speed even if the internal magnet rotates at a different speed.

Engineaccessory drive Flexible cable Rotating magnet + drag cup Cup shaft Hairspring + pointer Eddy-current torque
Original AeroLearn schematic: the rotating magnet induces eddy currents in the drag cup; the spring balances the resulting torque.

What happens as speed changes?

When engine speed rises, the magnet rotates faster. The changing magnetic field induces stronger eddy-current effects in the conductive cup, increasing the turning torque. The cup and pointer move against the hairspring until a new equilibrium is reached. When speed falls, the induced torque reduces and the hairspring returns the pointer toward a lower reading. The instrument converts rotational speed into a mechanical pointer position.

The response is not instantaneous. Moving parts have inertia, and damping is used to prevent excessive pointer oscillation. Excessive friction, a damaged spring, a weakened magnet, contamination or mechanical wear can produce lag, sticking, hysteresis or inaccurate readings. A flexible drive cable that is kinked, poorly routed or inadequately supported may create vibration or fluctuating indication.

Strengths and limitations

Exam point: The drag cup does not simply follow the magnet because it is physically attached to it. It is driven by induced eddy-current torque and restrained by a hairspring.
3 · Tacho-generator and indicator

Electrical tachometer system

An engine-driven tachometer generator is mechanically coupled to an engine shaft or accessory gearbox. A common arrangement uses a small three-phase AC generator. As its rotor turns, it produces an AC output whose frequency is proportional to generator speed, and therefore to the driven engine shaft speed when the drive ratio is known.

The signal travels through wiring to the indicator. In a representative system, a synchronous motor in the indicator follows the generator's electrical frequency. A magnetic-drag mechanism then converts rotation into pointer movement. Other designs use electronic signal conditioning and a different display arrangement; always use the system description for the aircraft type.

Engine shaftmechanical drive Tacho-generatorAC frequency signal Wiring /signal path IndicatorRPM / % RPM
Original AeroLearn signal-flow diagram for a representative engine-driven electrical tachometer.

From shaft rotation to an electrical signal

In a typical AC tachometer generator, a permanent-magnet rotor turns within stator windings. Each rotation produces an alternating output. The frequency of that output is directly related to generator speed; the output voltage may also vary with speed and system design. The indicator or electronic unit is calibrated to convert the signal into shaft RPM or percentage RPM.

Where a three-phase generator is used, the three electrical phases provide a robust signal to the indicator. In a representative older arrangement, the indicator contains a synchronous motor that follows the generator frequency. Its shaft drives a magnetic-drag mechanism, which moves the pointer. Modern systems may instead condition and digitise the signal before displaying it.

Key characteristics

Signal-chain thinking: When studying an electrical tachometer, separate the system into four stages: mechanical drive, sensor/generator, wiring and processing, then display. This helps locate the stage that may be responsible for an incorrect indication. It is a learning model, not an approved troubleshooting procedure.
4 · Tachometer probe system

Electronic speed sensing with a probe

Many turbine installations use a stationary speed probe positioned close to a rotating toothed wheel, gear or other target connected to the shaft being measured. In a variable-reluctance arrangement, a permanent magnet and coil establish a magnetic field. As each ferrous tooth passes the probe tip, the magnetic reluctance and flux change. The changing flux induces a voltage pulse in the coil.

The pulse frequency is proportional to shaft speed and the number of target teeth. Signal-conditioning electronics amplify and shape the pulses; a processor calculates speed and sends the result to a cockpit display or engine-control/monitoring system where the installation requires it. Other probe technologies, such as Hall-effect sensors, use different sensing physics but also provide speed-related electrical signals.

Targetwheel Probecoil + magnet Signal processorpulse rate → RPM Rotating shaft
Original AeroLearn conceptual illustration. Tooth passage changes magnetic flux at the stationary probe, producing pulses.

Probe installation and signal quality

The clearance between the probe tip and the rotating target is important. If the air gap is too large, magnetic coupling and output signal may become too weak. If the probe is incorrectly positioned or the target is damaged, the pulse train may be irregular. Metal debris attracted to a magnetic probe can also affect the sensing gap or signal quality. The correct gap, inspection method and limits are defined by the applicable maintenance data.

A variable-reluctance probe typically produces an alternating waveform whose frequency follows tooth-passing rate. Signal amplitude can change with speed and air gap, so the processor must detect valid pulses over the intended operating range. A Hall-effect sensor, by contrast, uses a semiconductor element to detect changes in magnetic field and may provide a more square-shaped digital pulse output.

Frequency relationship — worked example

A target wheel has 60 equally spaced teeth and produces 1,200 pulses per second. The shaft speed is:

RPM = (1,200 × 60) ÷ 60 = 1,200 RPM

Real installations may use a different number of teeth, pulse edges, processing method or scaling. The stated target geometry and system calibration must be known before converting pulse frequency into RPM.

Advantages and fault clues

5 · Comparing tachometer systems

What distinguishes the three methods?

SystemSpeed sensing principleTypical strengthsTypical limitations / fault areas
Magnetic-drag mechanicalFlexible drive rotates magnet; eddy-current torque moves drag cup against springSimple direct mechanical indication; no electronic signal chain requiredDrive cable wear, whipping, kinks, friction, internal instrument faults
Tacho-generatorEngine-driven AC generator; output frequency follows shaft speedElectrical transmission over wiring; can drive remote indicatorGenerator, wiring, connectors, indicator/synchronous motor faults
Tachometer probeMagnetic or other sensor detects passing teeth/targets; processor counts pulsesNo mechanical drive cable; suitable for electronic processing and multiple usesProbe gap/condition, target damage, wiring, processing or display faults
Interpretation caution: Do not diagnose an engine fault solely from a failed RPM indication. Compare other parameters and follow the aircraft checklist and maintenance data. A faulty indicator and an actual engine-speed abnormality are different problems.

Choosing the right interpretation

Each system has a different failure signature. A mechanical drive fault can create noise or pointer fluctuation. An electrical generator fault can produce a missing or unstable frequency signal. A probe installation fault can produce weak, intermittent or absent pulses. A display fault can occur even when the upstream signal is correct. These clues help organise technical reasoning, but they do not authorise in-flight maintenance or override abnormal-procedure checklists.

Observed symptomPossible area to considerImportant caution
Pointer fluctuates with engine vibrationFlexible drive, mounting, electrical connection or unstable sensor signalDo not assume the engine itself is fluctuating solely from the gauge.
Reading is consistently high or lowCalibration, drive ratio, wrong indicator or processing configurationCompare only using approved test procedures and limits.
Reading drops to zero or becomes flaggedOpen circuit, failed generator/probe, power or processor faultUse aircraft-specific procedures and cross-check other indications.
One spool indication disagrees with anotherDifferent spool behaviour, sensor channel fault or display faultN1 and N2 measure different rotating assemblies.
6 · Propeller auxiliary systems

What helps a propeller system operate?

A constant-speed propeller installation uses a governor to regulate propeller RPM by changing blade angle. The governor senses actual RPM and adjusts oil pressure or another control mechanism to move the blades toward a coarser or finer pitch as required. This is the fundamental propeller-control function; it is distinct from synchronisation between two engines.

On multi-engine aircraft, additional equipment may include a propeller synchroniser, synchrophaser, cockpit control switch, speed-reference circuits and engine/propeller speed sensors. Some installations use an electronic control unit; others use electromechanical or governor-based arrangements. A synchroniser typically adjusts one or more propeller governors to bring the slave propeller speed into agreement with the master reference.

Propeller governorRegulates an individual propeller's RPM by controlling blade pitch.
SynchroniserCompares propeller RPM and trims a slave engine/propeller toward the master RPM.
SynchrophaserControls RPM relationship and relative blade phase to reduce periodic noise.

Propeller auxiliary systems may also include feathering, autofeather, unfeathering accumulators, overspeed governors and beta/reverse-pitch controls on applicable aircraft. These are important propeller functions, but they are not all synchronisation devices. Their presence and logic vary by aircraft type.

Why propeller speed can change without a large power change

A constant-speed propeller governor senses RPM and adjusts blade pitch to maintain the selected speed. If airspeed or engine power changes, the aerodynamic and engine torques acting on the propeller change. The governor moves the blades toward a coarser or finer pitch as required to restore the selected RPM, within the governing range. The exact direction of oil flow and blade movement depends on propeller design.

Propeller control systems may include a governor, overspeed governor, feathering mechanism, unfeathering accumulator, beta/reverse control on applicable turboprops, and electrical or hydraulic actuators. These components have distinct functions. A synchroniser does not replace the primary governor; it normally makes a small correction to the slave governor's setting.

Keep the functions separate: The governor controls one propeller's selected RPM; the synchroniser trims relative RPM between propellers; the synchrophaser additionally controls relative blade phase.
7 · Synchronisation system

Matching propeller RPM

When two propellers rotate at slightly different speeds, their sound waves can produce a periodic beat. The crew may hear a fluctuating drone or pulsing noise. A propeller synchronising system is designed to reduce the difference in RPM between the selected master propeller and the slave propeller.

The system receives speed signals from both engines/propellers. It compares the measured speeds and produces a correction command for the slave governor or its control mechanism. The slave propeller's RPM is adjusted until it matches the selected reference within the system's operating tolerance.

Master propellerRPM reference Slave propellermeasured RPM Synchronisercompares speed signals Slave governorsmall RPM correction Feedback continues until speeds are matched
Original AeroLearn simplified control loop. Actual installations differ in sensor, control and actuator architecture.

Master and slave

The pilot generally establishes the desired power and propeller settings in accordance with the aircraft procedure, then selects synchronisation if permitted. Synchronisation does not replace correct power setting, engine monitoring or propeller control.

Manual synchronisation and the synchroscope

Where automatic synchronisation is not fitted, or is unavailable, a synchroscope can help the pilot compare propeller speeds. A common synchroscope uses a rotating pointer or disc driven by the difference between two engine speed signals. When the propeller speeds are equal, the display becomes stationary. When they differ, the direction and rate of rotation indicate which propeller is faster, subject to the instrument's markings and aircraft instructions.

The synchroscope indicates a speed difference; it does not directly prove that the propeller blades are at the desired angular phase. The pilot normally makes small adjustments to the appropriate propeller control in accordance with the aircraft flight manual. The display convention must be learned for the specific aircraft.

8 · Synchrophasing system

Matching speed and blade position

Synchronisation matches rotational speed. Synchrophasing goes further: it maintains a selected relationship between the angular positions of the blades on different propellers while keeping their rotational speeds matched. The relative angular position is commonly called blade phase.

Even when two propellers turn at exactly the same RPM, their blades may pass corresponding positions at different times. This can create an objectionable beat or cabin noise. A synchrophaser adjusts the relative phase relationship so that pressure pulses from the propellers interact in a more favourable way at the aircraft structure and cabin. It does not necessarily make the sound disappear; it aims to reduce the perceived noise or vibration for the installation's design objective.

Same RPM, different blade phase Same RPM, selected phase relationship Angular offset between blade setsControlled relative angular relationship
Conceptual top-view illustration only; blade count, rotation direction and selected phase angle are aircraft-specific.

How it operates

  1. Speed sensors establish each propeller's rotational speed.
  2. A phase reference identifies a repeatable angular position on each propeller shaft.
  3. The control unit compares speed and phase information.
  4. Small corrections to the slave propeller's speed temporarily advance or retard its angular position relative to the master.
  5. Once the desired phase relationship is achieved, the control maintains it while preserving the required RPM match.
Key distinction: Synchronisation = same RPM. Synchrophasing = same RPM plus a controlled relative blade-phase relationship.

Why phase matters even when RPM is matched

Two propellers can rotate at the same average RPM but have different angular positions at any instant. Their blade passages therefore reach the fuselage at different points in the rotation cycle. Depending on aircraft geometry, this can create objectionable periodic sound or vibration. Synchrophasing adjusts the relative phase angle so that recurring pressure pulses are arranged in a more favourable relationship.

Phase is an angular relationship, not a speed. If two propellers have the same RPM, their relative phase can remain constant; however, that constant phase may not be the preferred phase. A synchrophaser senses both speed and a reference related to blade position, then makes controlled corrections through the slave governor. The selected phase relationship and permitted operating range are type-specific.

Concept check: RPM answers “how fast is it rotating?” Phase answers “where are the blades in their rotation relative to the other propeller?” Both are needed for synchrophasing.
9 · Operating logic and practical considerations

Using and interpreting the systems

Typical operating sequence

  1. Set engine power and propeller controls in accordance with the aircraft checklist and operating manual.
  2. Confirm the engines and propellers are within the synchroniser's permitted operating range.
  3. Select the master/reference engine where the installation requires manual selection.
  4. Engage synchronisation or synchrophasing as directed by the aircraft procedure.
  5. Observe the indications and listen for changes in beat frequency or cabin noise.
  6. If the system hunts, fails to engage or produces an abnormal indication, use the approved procedure; do not attempt improvised adjustments.

Fault indications and likely areas

SymptomPossible system areasImportant distinction
RPM pointer fluctuatesMechanical cable whipping; loose connection; unstable generator/probe signal; instrument faultConfirm whether engine speed itself is fluctuating.
Indication remains at zeroBroken drive, failed generator/probe, wiring or display faultA zero reading does not prove the engine has stopped.
One spool indication failsThat spool's probe, wiring, processing channel or display inputOther spool indications may remain valid.
Synchroniser will not engageSpeed difference outside capture range, system inhibit, sensor or control faultCheck aircraft-specific engagement conditions.
Synchroniser huntsUnstable speed signal, control-loop fault, governor response or system adjustment issueDo not assume the cause is purely acoustic.
Noise remains despite matched RPMBlade phase not controlled, phase function not selected/available, or noise has another sourceEqual RPM alone does not guarantee the optimum phase relationship.
Operational safety: Engine and propeller limits, synchroniser engagement conditions, prohibited phases of flight and abnormal procedures are aircraft-specific. The AFM/POH, QRH and approved maintenance data take precedence over general study notes.
Worked examples

Apply the principles

Example 1 — RPM from shaft frequency
Example 2 — Tach-probe pulse conversion
Example 3 — Two propellers out of synchronisation
Example 4 — Same RPM does not mean same phase

Two propellers both turn at 1,600 RPM. Their angular positions may still be offset. A conventional synchroniser matches speed; a synchrophaser also controls relative blade phase.

Example 5 — Identifying a mechanical tachometer fault

A piston engine runs normally but the mechanical tachometer needle flickers and a drive-cable noise is heard. A damaged, kinked or whipping flexible drive is a plausible indication-system fault. Maintenance action must follow approved data.

Example 6 — Independent spool indications

A twin-spool engine shows a normal N1 indication but an absent N2 signal. Investigate the N2 sensing and processing path rather than assuming both spools have stopped.

Example 7 — Percentage RPM
Example 8 — Beat frequency concept

If two propellers rotate at slightly different speeds, the relative blade-pass pattern changes continuously. The resulting periodic sound modulation can be heard as a beat. Matching RPM reduces this relative drift; phase control can further improve the acoustic relationship.

Additional worked examples

Example 9 — Convert revolutions per second to RPMA shaft turns at 42 revolutions per second. RPM = 42 × 60 = 2,520 RPM.
Example 10 — Find pulse frequencyA 24-tooth target rotates at 1,500 RPM. Revolutions per second = 1,500 ÷ 60 = 25. Pulse frequency = 25 × 24 = 600 Hz.
Example 11 — Compare two propellersEngine A indicates 1,900 RPM and Engine B indicates 1,885 RPM. The difference is 15 RPM. A synchroniser may be able to trim this difference if it is within its approved authority; do not assume the system can correct any size of mismatch.
Example 12 — Interpret a stationary synchroscopeA synchroscope settles at the stationary position. This indicates that the two sensed speeds are matched within the instrument/system tolerance. It does not, by itself, prove that the propellers are at the preferred blade phase.
Chapter summary

What you must remember

Revision checklist

Knowledge check

Chapter 30 assessment — 12 questions

Choose one answer for each question, then submit to see your score and explanations.

1. On a conventional piston-engine installation, the tachometer normally indicates:

2. A turbine indication of 90% RPM means:

3. In a magnetic-drag tachometer, what produces torque on the drag cup?

4. The hairspring in a drag-cup instrument:

5. In a typical tacho-generator system, which parameter varies with engine speed?

6. A variable-reluctance tachometer probe detects speed by sensing:

7. A 30-tooth wheel produces 600 pulses per second. What is its speed?

8. On a two-spool turbine, N1 and N2:

9. The primary function of a constant-speed propeller governor is to:

10. A propeller synchroniser primarily:

11. What additional function does synchrophasing provide?

12. Two propellers rotate at exactly the same RPM. Which statement is correct?