AEROLEARN RWANDA/Aircraft General Knowledge/Chapter 32
AEROLEARN RWANDA · AIRCRAFT GENERAL KNOWLEDGE
INSTRUMENTATION · CHAPTER 32

Vibration Monitoring

How aircraft engine vibration is sensed, filtered, displayed and analysed to identify abnormal rotating-system behaviour and support engine health monitoring.

ATPL FOUNDATIONENGINE INSTRUMENTATION15 WORKED EXAMPLES12 KNOWLEDGE CHECKS
Introduction

Why monitor engine vibration?

An aircraft gas-turbine engine contains several high-speed rotating assemblies: fan, compressor rotors, turbine rotors, shafts, bearings and accessory drives. These components rotate at high speed and are supported by carefully designed bearings and casings. Small, controlled levels of vibration are normal. However, a sudden increase, an unusual frequency pattern or a progressive change in vibration can indicate an imbalance, mechanical deterioration or damage.

An engine vibration monitoring system (EVMS) measures mechanical oscillations at selected points on the engine, processes the sensor signals and presents a useful indication to the flight crew. More advanced systems also record detailed data for maintenance analysis, trend monitoring and engine balancing. The system is therefore both an operational monitoring tool and an important part of engine health management.

The system does not normally identify every failed component directly. It measures vibration response at the sensor locations. The monitoring computer uses engine-speed references, filtering and signal processing to distinguish vibration associated with different rotating assemblies. Maintenance specialists then combine this information with other evidence such as engine parameters, oil-debris findings, borescope results and recorded trends.

DetectIdentify abnormal vibration and alert the crew when applicable thresholds are exceeded.
SeparateUse engine-speed references and filters to distinguish N1, N2 or other rotor-related vibration.
DiagnoseRecord vibration data to help maintenance locate, assess and correct a developing problem.
Learning outcomes

By the end of this chapter, you should be able to:

1 · Vibration fundamentals

Understanding mechanical vibration

Vibration is the repeated or oscillating movement of a body about an equilibrium position. An engine casing may move by a very small amount as rotating components generate forces that are transmitted through bearings and structural supports. The movement may be periodic, random or a combination of different vibration sources.

Amplitude and frequency

Frequency (Hz) = Number of cycles ÷ Time (seconds)

For a rotating component, the once-per-revolution frequency is called the rotational frequency or 1× running speed. If a rotor turns at 12,000 RPM, its rotational frequency is 12,000 ÷ 60 = 200 Hz. A vibration component at 1× may be associated with rotor imbalance, although other faults can also produce vibration at this or related frequencies.

Wave A — lower frequency Wave B — higher frequency Same horizontal time scale: more cycles in the same time = higher frequency
Original AeroLearn diagram: vibration frequency is indicated by cycles per unit time; amplitude is the vertical magnitude.

Three ways to express vibration amplitude

QuantityWhat it describesCommon unitsInterpretation
DisplacementDistance moved from the mean positionµm, mm, milsHow far the structure moves.
VelocityRate of change of displacementmm/s, in/sHow quickly the structure moves.
AccelerationRate of change of velocitym/s², gHow quickly velocity changes.

Different monitoring systems display different amplitude quantities. Older systems may use relative amplitude or displacement in mils; other systems display velocity in inches per second (in/s); accelerometer outputs are often internally measured as acceleration. Never assume that the displayed number is in g, mils or in/s without checking the aircraft documentation.

Simple harmonic motion

A simple vibration can be represented by a sinusoidal waveform. In an ideal sinusoid, displacement, velocity and acceleration are related but are not at their maximum values at exactly the same point in the cycle. Acceleration is greatest near the extremes of displacement, while velocity is greatest as the body passes through its equilibrium position.

Exam distinction: A vibration sensor may be an accelerometer, but the cockpit display does not necessarily show acceleration. The monitoring computer can process the accelerometer signal and present a calibrated vibration value in another unit.
2 · Sources and effects

Why an engine vibrates

Some vibration is inherent in rotating machinery. The engine is designed with balancing, bearing support, damping and structural stiffness to keep normal vibration within acceptable limits. Abnormal vibration can occur when a rotating assembly becomes unbalanced, a component is damaged, a bearing deteriorates or an accessory drive develops a fault.

Common sources of abnormal vibration

Possible sourceHow it can produce vibrationExamples of associated clues
Rotor imbalanceUnequal mass distribution produces a rotating centrifugal force.Vibration may be strongly related to rotor speed and may change with RPM.
Fan or compressor blade damageMissing, bent, eroded or damaged blades disturb aerodynamic and mass balance.May follow foreign object damage, erosion or a blade event.
Turbine blade damageDamage or uneven deposits can disturb the rotating assembly and gas flow.May be accompanied by other engine parameter changes.
Bearing deteriorationWear, spalling, lubrication problems or damage changes rotor support and motion.May produce characteristic frequency components and progressive trends.
Shaft misalignment or rubIncorrect alignment or unwanted contact creates periodic or broadband vibration.May vary with load, temperature or operating speed.
Accessory gearbox or drive faultGear damage, eccentricity or an accessory fault transmits vibration into the engine structure.May be localised to particular frequencies or operating conditions.
Loose mountings or structural partsInsufficient restraint allows movement or resonance.May produce rattling or vibration that changes with operating condition.

Consequences of excessive vibration

Important: Vibration is a condition-monitoring parameter. It is not, by itself, a diagnosis of a particular failed component. Crew procedures and maintenance decisions use the complete set of indications and recorded evidence.
3 · Vibration sensors

Pick-ups and accelerometers

The sensor, also called a vibration pick-up or transducer, converts mechanical movement into an electrical signal. It is mounted at a carefully selected point on the engine casing, bearing support or frame. The location is chosen so that the sensor can detect vibration transmitted from the rotating assembly of interest while withstanding temperature, acceleration and environmental loads.

Piezoelectric accelerometer

A common modern sensor is the piezoelectric accelerometer. It contains a piezoelectric element that produces an electrical charge when mechanical force is applied. Inside the sensor, a seismic mass applies force to the piezoelectric crystal as the engine casing accelerates. The resulting electrical output is proportional to the applied dynamic force and, for a known mass, to acceleration.

The charge is very small and normally requires a charge amplifier or compatible signal-conditioning input. The sensor itself has no conventional moving pointer or mechanical linkage. Its internal mass and sensing element respond to the vibration of the engine structure.

Accelerometer housing Seismic mass Preload Piezo crystal Base / mounting surface Electricaloutput Engine casing acceleration excites the internal mass/crystal system
Original AeroLearn schematic: simplified piezoelectric accelerometer construction. Actual designs vary; some use compression, shear or other crystal arrangements.

Older electromagnetic vibration pick-up

Some earlier systems use an electromagnetic pick-up containing a suspended magnet and a coil. When the engine casing vibrates, the coil moves with the casing while the magnet tends to resist the movement because of inertia. Relative motion between the magnet and coil changes magnetic flux and induces an electrical voltage. The signal is then amplified and processed.

In this arrangement, the output depends on relative motion and sensor design. It is therefore important not to treat every vibration sensor as a piezoelectric accelerometer; the exact sensor principle depends on the aircraft system.

Sensor installation and location

Many engines use two vibration sensors, often positioned near forward and aft bearing structures or at other selected points. Multiple sensors help capture different structural responses and can provide an alternate channel if one sensor fails. The number, location and purpose are specific to the engine design.

Installation matters: Incorrect sensor torque, a damaged mounting pad, poor electrical shielding, loose connectors, cable chafing or incorrect sensor orientation can affect the measurement. Installation and test limits are specified by the approved maintenance data.
4 · Signal processing

From sensor signal to useful indication

The accelerometer output may contain vibration from several rotating assemblies and other sources. A signal-conditioning or vibration-monitoring unit processes the sensor signal so the crew can receive a meaningful indication rather than an uninterpreted electrical waveform.

Typical system components

    Accelerometersvibration signals N1 / N2 speedreference signals Signal conditionerand monitoringcomputer Cockpit displayvibration indication Warning / alertif fitted / threshold Maintenance datarecord / download Simplified functional architecture — actual aircraft integration varies
    Original AeroLearn block diagram: vibration and speed signals enter the monitoring computer, which supplies crew indications and maintenance outputs.

    Amplification and signal conditioning

    Accelerometer outputs can be very small. The input stage amplifies or converts the sensor signal to a suitable level. Filtering reduces unwanted noise and selects the frequency ranges needed for analysis. The system may also include analogue-to-digital conversion, scaling, compensation, self-test and fault monitoring.

    Why the speed signal is essential

    Suppose a two-spool engine has a low-pressure rotor (N1) and a high-pressure rotor (N2). Each rotates at a different speed. The monitoring computer receives the vibration signal and the corresponding speed references. It can then track frequency components that are synchronous with N1 or N2. This allows the system to estimate the vibration associated with each rotor even when the sensor receives a combined vibration signal from the whole engine structure.

    Tracking filters follow changes in rotor speed. A fixed-frequency filter would become less useful as the engine accelerates or decelerates because the rotor's 1× frequency changes with RPM. A tracking filter adjusts its centre frequency in relation to the speed reference.

    Core principle: Vibration sensors detect movement; speed sensors identify the rotating frequency; the monitoring computer separates and scales the relevant components.

    Frequency bands and rotor tracking

    Some older systems use selectable filters or switches to examine high- and low-frequency ranges, or to select different engine sensor locations. More modern systems automate the process and present separate N1 and N2 values. A particular aircraft may use one or more accelerometers and a set of digital tracking filters; the arrangement must be learned from its system description.

    5 · Indication and display

    How vibration is presented to the crew

    Older aircraft may have a dedicated vibration indicator for each engine. Some systems require the crew or maintenance personnel to select the sensor location and frequency band. Modern aircraft may display digital vibration values on an engine page or secondary display, with warning or caution messages when specified thresholds are exceeded.

    Common display arrangements

    System generationTypical presentationOperational feature
    Older analogue systemDedicated meter with relative amplitude scaleMay require selection of sensor and frequency filter.
    Electronic vibration indicatorDigital or bar indication, sometimes with N1/N2 selectionSignal conditioner filters and scales the measurement.
    Integrated engine displaySeparate vibration values for engine/rotor on EICAS/ECAM or other displayAutomatic monitoring, threshold alerting and maintenance recording may be integrated.

    Units and limits

    Vibration indication units vary by aircraft. Some systems use relative vibration units, some use mils or displacement, and others display velocity such as inches per second. The scale may be dimensionless and calibrated for a specific engine/monitoring system. A value such as “2.5” cannot be interpreted as a universal vibration severity without the relevant aircraft reference.

    Thresholds can also vary by rotor, engine type, operating condition and display architecture. A warning threshold on one engine family must not be copied to another. The aircraft flight manual and approved maintenance documentation define the correct limits and crew action.

    Important: A cockpit vibration indicator may show only a processed or maximum value, while the monitoring unit stores more detailed data for maintenance. The crew display is not necessarily a complete vibration spectrum.
    6 · Monitoring and diagnosis

    Interpreting vibration patterns

    Vibration monitoring is most useful when values are considered in context. A single reading may be affected by operating condition, transient acceleration, sensor location or system processing. A trend across multiple flights or engine runs can be more informative than an isolated value, particularly when a progressive increase is developing.

    Rotor imbalance and 1× vibration

    A rotor with an uneven mass distribution produces a centrifugal force as it rotates. The force direction rotates with the rotor, creating a vibration component at the rotor's rotational frequency. This is commonly called a 1× or once-per-revolution component. The amplitude may vary with speed, and the vibration response also depends on rotor support, structural resonance and sensor location.

    Rotational frequency (Hz) = Rotor speed (RPM) ÷ 60

    Harmonics and other vibration components

    Some faults produce components at multiples of running speed. A 2× component occurs at twice the rotational frequency; a 3× component occurs at three times the frequency. Other faults, including bearing defects and gear-mesh problems, may produce more complex frequency patterns. Detailed diagnosis usually requires vibration spectrum analysis and engine-specific knowledge.

    Pattern / featurePossible associationWhy it is not a definitive diagnosis
    Strong 1× running-speed componentRotor imbalance, eccentricity or misalignmentSeveral mechanical conditions can produce 1× response.
    2× or other harmonicsMisalignment, looseness, distortion or nonlinear responseInterpretation depends on machine configuration and spectrum.
    Broadband / irregular vibrationRubbing, turbulence, damage or multiple vibration sourcesRequires detailed analysis and correlation with other data.
    Progressive increase over timeDeveloping imbalance, wear, deterioration or changing installation conditionTrend must be compared at equivalent operating conditions.

    Trend monitoring

    Trend monitoring compares vibration measurements over time. For a useful comparison, the engine should be assessed at comparable power settings, speeds, temperatures and other relevant conditions. A rising vibration trend may prompt maintenance investigation before a limit is exceeded. A sudden step change can be equally important, even if the reading remains below a displayed alert threshold.

    Engine balancing

    Balancing aims to reduce vibration caused by an imbalance in a rotating assembly. In an engine trim-balance process, vibration data is collected at a defined operating condition. The phase reference and amplitude are used by approved maintenance procedures to calculate the correction required. A balance weight may then be installed at an approved location to counteract the measured imbalance.

    Balancing is not a general cure for all vibration. It is appropriate only when the underlying condition has been assessed and the approved procedure identifies balancing as the corrective action. Blade damage, bearing distress, rubbing, looseness or other mechanical defects must not be hidden by adding balance weights.

    Heavy spot / mass eccentricity Rotating centrifugal force Correction mass at approved location Unbalanced rotor (concept) Conceptual illustration only; real engine balancing uses measured amplitude and phase and approved procedures.
    Original AeroLearn diagram: an illustrative imbalance and a correction mass. Actual balancing calculations and weight locations are engine-specific.

    On-board and ground analysis

    On-board systems may calculate a vibration value and record event data. Ground-based engine health monitoring can examine more detailed signals, compare trends across flights and correlate vibration with N1/N2 speed, temperature, fuel flow, oil data and other parameters. This can support condition-based maintenance and reduce unnecessary component removal when the evidence points to a more limited issue.

    7 · System tests and limitations

    Testing, faults and maintenance considerations

    Vibration monitoring systems may include a test function or built-in test equipment (BITE). Depending on the aircraft, the test may check the indicator, processing electronics, warning circuit, wiring continuity or other system functions. A system test does not necessarily prove that the accelerometer is correctly mounted or accurately measuring engine vibration; test coverage is design-specific.

    Typical maintenance considerations

    System limitations

    Operational boundary: Flight crew must follow the aircraft's abnormal procedures and operating limitations for an abnormal vibration indication. This chapter does not provide a generic in-flight response or permission to continue operating an engine with an exceedance.
    8 · Worked examples

    Calculations and practical interpretation

    Example 1 — Convert RPM to frequencyA rotor turns at 9,000 RPM. Frequency = 9,000 ÷ 60 = 150 Hz.
    Example 2 — Convert frequency to RPMA vibration component is synchronous with a shaft at 250 Hz. Shaft speed = 250 × 60 = 15,000 RPM.
    Example 3 — Identify a 2× componentA rotor runs at 120 Hz. A 2× component occurs at 2 × 120 = 240 Hz.
    Example 4 — Identify a 3× componentA shaft runs at 180 Hz. Its third harmonic is 3 × 180 = 540 Hz.
    Example 5 — Calculate cyclesA sensor signal contains 400 cycles in 2 seconds. Frequency = 400 ÷ 2 = 200 Hz.
    Example 6 — Understand amplitudeA vibration waveform rises from ±2 units to ±4 units while its frequency remains unchanged. The amplitude has doubled; the vibration frequency has not changed.
    Example 7 — Compare two rotor speedsN1 is 4,800 RPM and N2 is 12,600 RPM. Their 1× frequencies are 80 Hz and 210 Hz respectively. A tracking system can use these references to separate the rotor-related vibration components.
    Example 8 — Interpret a rising trendVibration increases from 1.1 to 1.5 to 1.9 units over comparable engine runs. This progressive rise warrants review under the applicable maintenance programme even if a published alert threshold has not yet been reached.
    Example 9 — Interpret a sudden step changeVibration is stable over several flights and then suddenly increases after a reported bird or foreign-object event. The event history and other engine indications are relevant to the maintenance investigation.
    Example 10 — Sensor output versus displayAn accelerometer produces an electrical signal related to acceleration. The monitoring computer processes and scales the signal; the cockpit display may show a relative unit or velocity rather than acceleration in g.
    Example 11 — Two sensorsA forward sensor and an aft sensor are fitted to an engine. Their different mounting positions allow the system or maintenance personnel to compare structural responses and may provide an alternate channel if one sensor is unserviceable.
    Example 12 — N1/N2 trackingThe vibration signal contains energy at 150 Hz and 220 Hz. The engine speed references show N1 at 150 Hz and N2 at 220 Hz. Tracking filters can identify the components associated with each spool.
    Example 13 — Vibration unit cautionAn aircraft display reads 2.4 vibration units. Without the aircraft-specific definition, it is not valid to call this 2.4 g, 2.4 mils or 2.4 in/s.
    Example 14 — Possible imbalanceA strong 1× vibration component is measured at the fan speed. Rotor imbalance is one possible cause, but blade damage, misalignment and other faults must also be considered.
    Example 15 — Why a filter tracks speedAs an engine accelerates, N1 increases from 100 Hz to 130 Hz. A tracking filter follows the change so it continues to monitor the N1-synchronous component rather than remaining fixed at 100 Hz.
    Chapter summary

    Key points to remember

    Revision checklist

    Knowledge check

    Test your understanding

    Choose one answer for each question. Submit to see your score and explanations.

    1. What does vibration frequency represent?

    2. What is the operating principle of a piezoelectric accelerometer?

    3. What is the primary function of the vibration sensor?

    4. Why does the vibration monitoring computer use N1 and N2 speed signals?

    5. A rotor runs at 6,000 RPM. What is its 1× frequency?

    6. A shaft's running frequency is 150 Hz. What is its 2× harmonic?

    7. A strong 1× vibration component can be associated with:

    8. A cockpit vibration indication reads 2.0. What can be concluded without the aircraft documentation?

    9. What is the advantage of a tracking filter?

    10. Why is trend monitoring useful?

    11. Which statement about engine balancing is correct?

    12. What does a high vibration indication prove?

    References and further study

    Technical references

    AeroLearn learning note: This chapter is an educational explanation of aircraft engine vibration monitoring. It is not an approved maintenance procedure or flight crew checklist. Sensor configuration, indication units, thresholds, alert logic and corrective actions vary by aircraft and engine. Always use current approved manufacturer documentation.