Introduction and learning outcomes
A piston-engine fuel system must store fuel safely and deliver a continuous supply of clean fuel to the engine at the pressure and flow required by every approved operating condition. It must continue to function as fuel quantity decreases, the aircraft changes attitude, altitude and power, and the engine demand changes.
The system is more than a tank and a pipe. It includes tank vents, drains and sumps, selector valves, fuel lines, strainers and filters, pumps, pressure regulation, priming arrangements, fuel quantity and pressure indications, and the engine fuel-metering equipment. The airframe fuel system delivers fuel to the engine interface; the engine fuel system then meters fuel to the induction system or cylinders. The exact boundary and component arrangement vary by aircraft and engine.
Learning outcomes
- Explain the purpose and performance requirements of an aircraft piston-engine fuel system.
- Trace fuel from tank to engine and distinguish airframe supply from engine metering.
- Explain gravity-feed and pump-fed system operation.
- Describe tanks, vents, expansion space, baffles, sumps, drains and selectors.
- Explain the roles of engine-driven and auxiliary pumps.
- Describe strainers, filters, fuel lines, shutoff valves and pressure indications.
- Understand fuel density, volatility, vapour formation and contamination hazards.
- Explain fuel quantity indication limitations and operational fuel management.
- Recognise common fuel-system faults and their possible symptoms.
Fuel-system requirements
Fuel must reach the engine in sufficient quantity, at a suitable pressure, without interruption or unacceptable contamination. The system must also prevent leakage, minimise fire risk, allow safe servicing and provide the crew with useful indications of fuel quantity and system condition.
Fundamental requirements
Airframe supply versus engine fuel metering
The airframe fuel system normally includes tanks, vents, drains, selector valves, lines, strainers and pumps. The engine fuel system includes the components that control and distribute the fuel in relation to engine demand, such as a carburettor or fuel-injection metering unit. Some components are installed on the engine but remain part of the broader supply path. The division is conceptual; the manufacturer's system diagram is authoritative.
Fuel-system architecture
A representative flow path is shown below. Not every aircraft uses every component, and component order can vary. Some systems use gravity, some use engine-driven pumps, and many pump-fed systems include an electric auxiliary pump.
Fuel tanks, vents, expansion space and sumps
Fuel tanks may be installed in wings, fuselage or other approved locations. Their design must accommodate structural loads, fuel expansion, aircraft acceleration and changes in attitude. Common constructions include integral tanks formed by sealed structural compartments, rigid metal tanks and flexible bladder cells.
Tank construction and internal features
Tank venting
As fuel leaves a tank, air must enter to replace its volume. Without an effective vent, tank pressure can fall below ambient pressure and oppose fuel flow. A blocked vent can therefore cause fuel starvation even when fuel remains in the tank. Vent design also manages pressure changes with altitude and temperature. Some systems interconnect tank vent spaces; others use individual vents.
Tank outlet, finger strainer and unusable fuel
The tank outlet is not necessarily at the absolute bottom of the tank. A pickup may be positioned above a sump so that settled water and heavier debris are less likely to be drawn directly into the engine feed line. A coarse finger screen at the outlet provides first-stage protection against larger particles. A separate low-point sump and drain allow contamination to be sampled and removed.
Fuel expansion and vent/overflow arrangements
Fuel expands as its temperature rises. Tanks therefore require an allowance for expansion and a vent/overflow arrangement that prevents damaging pressure build-up or unintended fuel loss. A vent line must be routed and protected so that it is not blocked by dirt, insects, ice, water or deformation. Some aircraft use a vented filler cap; others use dedicated vent lines and surge/overflow spaces. A vent outlet exposed to airflow may be designed to provide a small pressure effect, but the exact arrangement is type-specific.
Fuel sumps and drains
Water and many solid contaminants are denser than aviation gasoline and tend to settle at low points. Sumps and drains allow accumulated water and sediment to be sampled and removed. A tank drain may be located at the tank low point; a gascolator or main strainer may have its own sump and drain. The sampling sequence and quantity are aircraft-specific.
Gravity-feed fuel systems
A gravity-feed system uses the vertical height of the fuel tanks above the engine fuel metering equipment to provide the pressure needed for fuel flow. It is commonly associated with high-wing aircraft where the tanks are above the carburettor. Fuel flows from the tank through a selector valve and strainer to the carburettor.
How gravity feed works
- Fuel is stored in tanks positioned above the carburettor or metering unit.
- Gravity creates a pressure head due to the vertical difference between fuel level and the delivery point.
- The selector valve directs fuel from the chosen tank or combination of tanks.
- The fuel passes through the strainer, where water and sediment can be collected.
- The carburettor receives fuel at the pressure available from the system design.
The theoretical pressure head increases with fuel density and vertical height:
where ΔP is pressure difference, ρ is fuel density, g is gravitational acceleration and h is vertical fuel head. This simplified hydrostatic relationship ignores line losses, acceleration effects and detailed tank geometry.
Effect of aircraft attitude and acceleration
The useful fuel head depends on the position of the fuel surface relative to the outlet and delivery point. Pitch, roll, sideslip and acceleration can move the fuel surface and temporarily uncover a pickup if the tank geometry and collector arrangement do not maintain coverage. Baffles, flapper valves, collector compartments and suitable pickup placement help preserve supply. The design is validated for defined conditions; do not assume a system can feed continuously in every conceivable attitude.
Gravity feed is simple, but it still depends on an open vent, an available tank, a clear selector/line/strainer path and sufficient vertical head. A blocked strainer or vent can defeat an otherwise simple arrangement.
Advantages and limitations
| Advantages | Limitations |
|---|---|
| Simple construction; fewer pumps and fewer pump-related failure modes. | Requires tank placement that provides adequate head. |
| Fuel can flow without an engine-driven pump. | Pressure head changes as fuel level changes and with aircraft attitude/acceleration. |
| Often light and straightforward in smaller aircraft. | Must be designed to maintain adequate flow under approved conditions. |
Pump-fed fuel systems
When gravity cannot provide sufficient pressure—such as where tanks are below the engine—pumps move fuel to the metering equipment. A common arrangement uses an engine-driven pump for normal operation and an electrically powered auxiliary or boost pump for starting, backup or other specified phases.
Engine-driven pump
The engine-driven pump is mechanically operated by the engine and supplies fuel during normal running. Many reciprocating-engine systems use a diaphragm-type pump, although pump design varies. A diaphragm pump uses alternating pressure or mechanical movement to draw fuel into a chamber through an inlet check valve and discharge it through an outlet check valve. The valves prevent reverse flow and maintain directional delivery.
Auxiliary / boost pump
An electrically driven pump can provide fuel pressure before the engine-driven pump is operating, support starting, help prevent vapour formation in susceptible systems, or provide a backup if the engine-driven pump fails. Its intended use differs by aircraft: it may be required for takeoff, landing, tank changes or emergency operation, or it may have a narrower role. Never infer pump-switch procedures from a generic description.
Positive-displacement pump principles
Many aircraft fuel pumps are positive-displacement devices: each operating cycle or rotation displaces a defined volume of fuel. A diaphragm pump uses a flexible diaphragm and inlet/outlet check valves; an electrically driven pump may use a rotary, vane, gerotor or other design. The pump creates the pressure differential needed to move fuel, while the system regulator, bypass or return arrangement controls pressure where fitted.
A pump's rated delivery is not the same as the fuel flow actually consumed by the engine. In a system with a return line, excess fuel may circulate back to a tank or collector. In a carburettor system, the float chamber and needle valve help regulate the fuel level delivered to the metering system. In a fuel-injected system, a fuel servo or metering unit controls fuel delivery according to airflow, engine demand and design logic.
Priming for engine start
A primer provides additional fuel for starting, especially when a cold engine cannot readily vaporise enough fuel through the normal induction path. A manual primer may draw fuel from the supply and deliver it to selected cylinders or the induction system. Fuel-injected engines may use an electric pump and mixture-control procedure instead. Over-priming can create an excessively rich mixture or an induction fire hazard. A manual primer, where fitted, must be secured as specified after use; an unlocked primer can move and admit unintended fuel.
Pump failure and redundancy
If the engine-driven pump fails, an auxiliary pump may maintain supply if the system is designed for that purpose and the pump is operated in accordance with the AFM/POH. A pump failure may cause fuel pressure to fall, engine power to fluctuate or the engine to stop. The crew should follow the aircraft checklist rather than attempting improvised switching or diagnosis.
Fuel lines, selectors, shutoff valves and strainers
Fuel lines
Fuel lines connect tanks, valves, pumps, filters and engine components. They must be compatible with the fuel, pressure, temperature, vibration and installation environment. Lines are routed to avoid chafing, excessive heat, sharp bends and unsupported spans. Flexible hoses accommodate relative movement where specified; rigid lines are used where their installation is suitable.
Fuel selector valve
The selector valve allows the pilot to choose the source tank or tanks and, in many installations, shut off the supply. Common light-aircraft selector markings include LEFT, RIGHT, BOTH and OFF, but not all aircraft have all four positions. A selector may also include crossfeed or other transfer functions on more complex aircraft.
The BOTH position can allow fuel to feed from both wing tanks in some systems. Other systems do not permit simultaneous feed from both tanks. The approved operating limitations may restrict a particular tank selection during takeoff, landing, climb or manoeuvring.
Strainers, filters and gascolators
Filters can become restricted by contamination. A blocked filter increases flow resistance and can reduce fuel pressure or flow at the engine. Some systems include bypass arrangements, but bypass logic is installation-specific and should not be assumed.
Filter staging and pressure loss
Fuel cleanliness is usually managed in stages. A coarse tank outlet screen intercepts larger debris; a gascolator or main strainer collects water and smaller particles; and an engine-mounted filter or metering-unit screen provides finer protection. The actual arrangement and filtration rating vary. Every restriction produces a pressure loss that increases with flow rate and restriction severity. A dirty filter can therefore allow apparently normal operation at low power but restrict delivery when the engine demands more fuel.
Return lines and vapour-return paths
Some fuel-injected engines return excess fuel to a tank or selected supply circuit. A return line may also help purge vapour or maintain circulation through a metering system. Check valves and selector logic prevent unwanted reverse flow or cross-connection. A blocked, leaking or incorrectly routed return line can affect pressure, fuel temperature or engine operation. Never assume that every piston-engine system has a return line.
Fuel line routing and heat protection
Lines should be supported, protected against chafing and routed away from exhaust heat and moving controls. Flexible hose is used where relative movement or vibration requires it, but hose type, bend radius, support and replacement life are controlled by approved data. A high point can trap vapour in some installations; a low point can trap liquid or contamination. The system designer accounts for these features and the aircraft's operating envelope.
Shutoff valves and fire safety
A fuel shutoff valve isolates the fuel supply when required by the aircraft procedure. Some aircraft have a firewall shutoff valve between the airframe supply and engine. Correct operation and sealing are important for fire protection and maintenance. The valve's location, control and emergency use are aircraft-specific.
Fuel quantity and pressure indications
Fuel quantity systems
Fuel quantity may be measured by a float-operated sender, capacitance probes or another approved sensing arrangement. A float sender changes electrical resistance or signal according to fuel level. A capacitance system uses the change in electrical properties as the immersed probe length changes. Modern displays may calculate or process signals electronically.
Indication accuracy can be affected by aircraft attitude, fuel movement, calibration, tank geometry, electrical faults and sensor condition. A cockpit gauge is an important monitoring aid, but it is not a substitute for fuel planning, physical inspection and cross-checking.
Float-type senders
A float follows the fuel surface and moves a linkage or magnetic coupling connected to an electrical sender. The sender changes resistance or produces a signal corresponding to level. The arrangement is relatively simple, but tank shape, float travel, sender calibration, electrical faults and aircraft attitude can affect the indication. A float measures local level, not fuel mass directly.
Capacitance-type gauging
A capacitance probe forms part of an electrical capacitor. As fuel level changes, the proportion of probe surrounded by fuel rather than air changes the effective dielectric constant and therefore the capacitance. Several probes may be distributed through a tank to account for irregular tank geometry. Signal-conditioning equipment converts the measured electrical change into a quantity indication. Calibration may account for tank shape and fuel density assumptions. Capacitance gauging is common on larger aircraft, but is not universal.
Fuel pressure indication
A fuel pressure gauge or transducer indicates pressure at a defined point in the system. Low pressure may indicate pump malfunction, low fuel supply, a blocked filter, air ingress or another fault. High pressure may indicate regulator or return-line issues in systems that use pressure regulation. Correct interpretation depends on the system and engine data.
Quantity, mass and volume
Fuel can be measured by volume (litres or US gallons) or by mass (kilograms or pounds). Mass is less affected by temperature-related volume expansion. If a fuel quantity is indicated by volume, fuel density is needed to convert it to mass.
Always use the fuel density and units appropriate to the actual fuel and temperature. Do not use a generic density for dispatch or flight planning where approved data is available.
Aviation gasoline and fuel characteristics
Spark-ignition aircraft piston engines commonly use aviation gasoline (AVGAS) approved for the engine. The required grade is specified by the engine and aircraft documentation. Fuel grade relates to anti-knock performance; it is not a simple statement that one fuel contains more energy than another.
Octane / performance number
Anti-knock quality describes a fuel's resistance to abnormal autoignition and detonation under the test method and rating system. A fuel with inadequate anti-knock quality can allow detonation under high cylinder pressure and temperature. The engine's specified minimum grade must be used. Never substitute automotive gasoline or another aviation fuel unless the aircraft and engine are specifically approved for it.
Volatility
Volatility describes how readily a fuel evaporates. Adequate volatility supports starting and mixture preparation, but excessive volatility under some pressure and temperature conditions can encourage vapour formation in fuel lines. Fuel volatility is therefore a balance between good vaporisation for combustion and manageable handling and supply characteristics.
Density and temperature
Fuel volume expands as temperature rises and contracts as temperature falls. For the same mass of fuel, a warmer fuel occupies a greater volume. This matters when converting between litres/gallons and kilograms/pounds, and when comparing volume-based quantities. Density is affected by fuel composition and temperature.
Fuel colour and identification
AVGAS grades may use dye colours as an identification aid, but colour alone is not a reliable method of determining fuel suitability or condition. Contamination, fading, mixed fuels and lighting can mislead. Use the fuel documentation, approved markings, delivery records and proper sampling procedures.
Contamination and its effects
Water
Water may enter through condensation, contaminated supply, leaking filler caps or maintenance errors. Free water can settle in low points and sumps. Suspended or emulsified water may not separate immediately. In freezing conditions, water can freeze and block lines, filters or small passages. In warmer conditions it can reach the metering unit and interrupt fuel delivery or combustion.
Particulate contamination
Rust, dust, sealant fragments, fibres and other particles can block strainers, damage pumps or obstruct precision metering passages. Filters reduce risk but cannot compensate for poor fuel handling or contaminated storage.
Microbial contamination
Microbial growth is a more familiar issue in water-contaminated turbine-fuel systems, but general contamination control remains important in all aircraft fuel systems. For AVGAS aircraft, follow the manufacturer's inspection and maintenance requirements and do not apply turbine-fuel microbial treatment assumptions without approval.
Fuel sampling and inspection
- Use the aircraft-specific preflight sampling points and sequence.
- Allow a sample to settle where the procedure requires it, so water and sediment can be identified.
- Inspect for water, cloudiness, particles, unusual colour or other abnormal appearance.
- If contamination is found, continue the approved sampling/draining procedure and investigate the source.
- Do not take off until contamination is resolved in accordance with the applicable procedure.
Vapour formation and vapour lock
Fuel can vaporise when its local pressure falls or its temperature rises sufficiently. In a fuel line, vapour bubbles can reduce the effective liquid flow and interfere with pump operation. This phenomenon is particularly relevant where fuel is hot, pressure is low, lines are routed near heat sources or the system is susceptible to suction-side pressure loss.
Vapour lock
Vapour lock occurs when fuel vaporises in a line or pump and the resulting vapour obstructs or disrupts liquid fuel delivery. A pump designed to move liquid may be unable to move vapour effectively, causing reduced pressure, fuel starvation, rough running or engine stoppage.
Factors that encourage vapour formation
- High fuel temperature, including heat soak after shutdown.
- Low pressure on the suction side of a pump.
- High altitude and reduced ambient pressure, depending on system design.
- High fuel volatility.
- Restricted lines, filters or strainers that increase pressure loss.
- Hot routing or inadequate cooling of fuel lines and components.
Vapour lock versus fuel starvation
Fuel starvation is an inadequate supply of fuel to the engine for any reason. Vapour lock is one possible mechanism that interrupts liquid fuel delivery. A blocked vent, empty selected tank, closed selector, pump failure or blocked filter can also cause fuel starvation without vapour lock.
Operational fuel management
Fuel quantity cross-check
Before flight, quantity should be verified using the aircraft's approved physical method, such as calibrated dipstick or visual inspection where provided, and compared with cockpit indications. Fuel gauges should not be treated as the sole source for fuel quantity. Records, refuelling receipts and known usable capacity also support the cross-check.
Tank selection and balance
Where selectable tanks are installed, the pilot must follow the prescribed tank-selection schedule. Changing tanks can help manage lateral balance and fuel availability, but incorrect selection or allowing a tank to run dry may introduce air into the system and interrupt engine operation. Some aircraft prohibit certain selections during takeoff, landing or specific manoeuvres.
Auxiliary pump use
The boost pump may be required for starting, takeoff, landing, tank switching, hot-weather operation or backup. The correct use depends on the aircraft. Continuous operation when not required may cause excessive fuel pressure or alter the metering system on some designs. The AFM/POH is controlling.
Selector logic: LEFT, RIGHT, BOTH and OFF
Some light aircraft use a four-position selector. LEFT or RIGHT isolates one tank; BOTH allows the system to draw from both tanks if the plumbing and design permit; OFF closes the supply. Other aircraft use only LEFT/RIGHT/OFF or more complex selector arrangements. A BOTH position is not automatically safe or available in every design: tank venting, interconnection, wing dihedral, fuel-head differences and the system's ability to prevent air being drawn from a depleted tank all matter.
Cross-feed versus fuel transfer
Fuel exhaustion, starvation and imbalance
These terms are not interchangeable. A fuel starvation event may occur with substantial fuel remaining in another tank. A fuel exhaustion event can occur when all usable fuel has been consumed.
Common fuel-system faults and symptoms
| Possible fault | Possible indication | Reasoning |
|---|---|---|
| Blocked tank vent | Falling fuel flow/pressure, power loss after time | Tank vacuum opposes fuel outflow. |
| Blocked strainer/filter | Low fuel pressure or reduced flow | Restriction increases pressure loss. |
| Engine-driven pump failure | Low pressure, roughness or engine stoppage | Normal pressure source is lost. |
| Auxiliary pump failure | Abnormal pressure during start or backup operation | Electric pump cannot provide its designed support. |
| Water contamination | Rough running, misfire or stoppage | Water reaches metering equipment or freezes in a line. |
| Incorrect tank selection | Fuel starvation despite fuel remaining elsewhere | Selected tank may be empty or unavailable. |
| Fuel leak | Fuel odour, visible staining, unexplained quantity loss | Fuel escapes before reaching the engine. |
| Vapour lock | Intermittent fuel pressure/flow, power loss | Vapour disrupts liquid fuel delivery. |
Symptoms overlap with ignition, induction and engine mechanical faults. A diagnosis must use the aircraft's approved troubleshooting procedures and should not be based on one indication alone.
Worked examples — 25
Example 1 — Fuel path tracing
Trace a representative pump-fed system from the tank to the engine.
Example 2 — Gravity head pressure
Assume fuel density 720 kg/m³, vertical head 0.8 m and g = 9.81 m/s².
Example 3 — Fuel mass from volume
Assume 90 L of fuel at 0.72 kg/L.
Example 4 — Volume from mass
For 72 kg at 0.72 kg/L:
Example 5 — Temperature and volume
A fuel sample expands from 50 L to 51 L as it warms.
Example 6 — Blocked tank vent
The engine loses power after operating from a tank whose vent is obstructed.
Example 7 — Water in a sump
A preflight sample shows a distinct water layer below the fuel.
Example 8 — Filter restriction
A partially blocked filter creates a pressure drop of 12 kPa at the required flow.
Example 9 — Pump redundancy
An engine-driven pump fails while an auxiliary pump is available.
Example 10 — Gravity-feed suitability
A high-wing aircraft has tanks above the carburettor.
Example 11 — Low-wing aircraft pump need
The tanks are below the engine metering equipment.
Example 12 — Tank selector mistake
The selected tank is empty while another tank contains usable fuel.
Example 13 — Fuel imbalance
One wing tank contains 45 L and the other 25 L.
Example 14 — Fuel exhaustion versus starvation
An engine stops with 30 L remaining in an unselected tank.
Example 15 — Vapour lock mechanism
Hot fuel in a low-pressure line begins to vaporise.
Example 16 — Sump drain purpose
Why are drains fitted at fuel-system low points?
Example 17 — Tank baffle purpose
Why does a tank contain internal baffles?
Example 18 — Expansion space
Why should a tank not be filled beyond its specified level?
Example 19 — Fuel gauge cross-check
The cockpit gauge indicates 40 L but the approved physical check indicates materially less.
Example 20 — Pressure gauge interpretation
Fuel pressure drops below the published normal range.
Example 21 — Filter and water
Why does a gascolator often include a sump bowl?
Example 22 — Fuel colour
A sample colour appears similar to the expected fuel grade. Is this sufficient to confirm suitability?
Example 23 — Engine-driven pump normal role
Why is the engine-driven pump normally the primary pressure source in a pump-fed reciprocating engine?
Example 24 — Fuel mass and density
Two equal 100 L volumes are measured at different densities: 0.70 and 0.74 kg/L.
Example 25 — Fuel system integrity
A pilot notices fuel staining and an unexplained quantity decrease during the walk-around.
Example 26 — Unusable fuel and dispatch quantity
A tank contains 52 L total, of which 3 L is specified as unusable. What is the nominal usable quantity?
Example 27 — Fuel flow and endurance
An aircraft has 48 L usable fuel and the assumed cruise consumption is 24 L/h. Calculate theoretical endurance before reserves.
Example 28 — Fuel required for a planned time
A planned flight segment is 1.4 h at 27 L/h. Estimate the segment fuel.
Example 29 — Tank imbalance by mass
Left tank contains 36 L and right tank 29 L. Assume density 0.72 kg/L. Calculate the mass difference.
Example 30 — Gravity head change
If the effective vertical fuel head falls from 1.0 m to 0.5 m, what happens to ideal hydrostatic pressure head?
Example 31 — Pump pressure and filter restriction
A pump outlet indicates 35 kPa and a downstream restriction causes a 7 kPa pressure drop. What is the ideal pressure remaining after that restriction, ignoring other losses?
Example 32 — Return-line function
A fuel-injected engine returns excess fuel to a tank. Why is the return line not simply an unnecessary leak?
Example 33 — Primer security
A manual primer is left unlocked after starting. What is the concern?
Example 34 — Float gauge limitations
Why might a float-type quantity gauge fluctuate during a steep turn?
Example 35 — Capacitance principle
What physical property changes when fuel replaces air around a capacitance probe?
Operational scenarios
Scenario A — Engine loses power with fuel remaining
Scenario B — Water found during preflight sampling
Scenario C — Fuel pressure falls after takeoff
Scenario D — Hot restart difficulty
Scenario E — Fuel gauge disagrees with physical check
Chapter summary
- The fuel system must deliver a continuous supply of clean fuel at the required pressure and flow throughout the approved operating envelope.
- Fuel-system design can be understood as five functions: storage, venting, selection/transfer, conditioning/delivery and indication/management.
- The airframe fuel system stores, selects, filters and supplies fuel; the engine metering system controls delivery to the induction system or cylinders.
- Tanks may be integral, rigid or bladder type and include features such as baffles, expansion space, vents, sumps, drains, outlet screens and collector spaces.
- Usable fuel is not necessarily the same as total tank capacity; unusable fuel is defined by the approved aircraft data.
- Tank vents allow air to replace fuel leaving the tank. A blocked vent can restrict fuel flow.
- Water and sediment settle at low points and can be removed through drains and strainers.
- Gravity-feed systems use vertical fuel head; pump-fed systems use pumps where gravity cannot provide adequate supply pressure.
- Engine-driven pumps normally supply fuel during running; auxiliary pumps support specified starting, backup or operational functions.
- Selector valves control which tank supplies the engine. Their positions and limitations vary by aircraft.
- Filters and strainers protect metering equipment but can become restricted by contamination; filter restriction creates pressure loss, especially at high flow demand.
- Some systems use return lines to circulate excess fuel or support pressure and vapour management; not all piston systems have them.
- Fuel quantity gauges require cross-checking. Fuel may be measured by volume or mass; density is needed for conversion.
- Fuel grade and compatibility must meet engine and aircraft requirements. Colour alone is not sufficient identification.
- Vapour lock occurs when fuel vapour disrupts liquid delivery; it is distinct from other causes of fuel starvation.
- Fuel exhaustion means usable fuel is consumed; fuel starvation means fuel is not reaching the engine.
- Operational pump use, tank selection, priming and sampling procedures must follow the AFM/POH.
- Float senders measure local fuel level; capacitance probes use changes in dielectric properties to infer tank contents.
- Cross-feed changes the source supplying an engine; transfer physically moves fuel between tanks.
Revision checklist
- ☐ Trace the complete fuel path from tank to engine metering equipment.
- ☐ Explain tank venting, baffles, expansion space and sumps.
- ☐ Compare gravity-feed and pump-fed systems.
- ☐ Explain engine-driven and auxiliary pump roles.
- ☐ Describe selector valves, strainers, filters and gascolators.
- ☐ Explain fuel quantity and pressure indications and their limitations.
- ☐ Define density, volatility and anti-knock quality.
- ☐ Explain water contamination and fuel sampling.
- ☐ Distinguish vapour lock, fuel starvation and fuel exhaustion.
- ☐ Explain why fuel management and tank selection are aircraft-specific.
Interactive knowledge check — 12 questions
Select one answer for each question and submit. Each response includes an explanation. Aim for at least 10/12 before moving on.