1. Introduction to Fuel Systems
An aircraft fuel system must store the correct fuel, protect it from contamination, deliver it to the engine at the required pressure and flow rate, indicate the quantity reliably, and permit safe refuelling and (where fitted) defuelling or jettisoning.
Fuel is not simply a payload carried in tanks. It is a working fluid whose physical properties change with temperature and pressure. The system must therefore manage fuel vapour, water, static electricity, thermal expansion, tank ventilation, pump supply, transfer between tanks and the aircraft’s changing centre of gravity.
The design differs with aircraft size and engine type. A high-wing piston aeroplane may use gravity feed, while a low-wing piston aircraft normally requires pumps. A transport jet uses multiple tanks, booster pumps, cross-feed arrangements, automatic protections and a capacitance-based fuel-contents system.
By the end of this chapter, you should be able to explain fuel properties and grades; identify contamination hazards; compare rigid, flexible and integral tanks; trace light-aircraft and twin-jet fuel flow; describe pumps, valves and indications; explain capacitive gauging; and outline safe refuelling, fuel jettisoning and fuel trimming.
How to think about a fuel system
Where is usable fuel located, and how is it kept near the pickup during manoeuvres?
What creates the pressure difference that moves fuel to the engine?
What prevents water, debris, leakage or a failed component from interrupting supply?
How does the crew know the quantity, pressure, flow and temperature are acceptable?
2. Fundamental Fuel Properties
Fuel properties determine how readily fuel vaporises, how safely it can be handled, whether it can be pumped at low temperature and how it behaves in the engine’s induction or injection system.
The tendency of a liquid fuel to change into vapour. High volatility assists cold starting but increases vapour-lock risk.
The pressure associated with a fuel’s tendency to vaporise. A high value means vaporisation can occur at a higher ambient pressure.
The lowest temperature at which enough vapour exists above the liquid to ignite momentarily. A flash does not mean a sustained flame.
The lowest temperature at which vaporisation can sustain combustion.
The temperature at which fuel ignites spontaneously without an external ignition source.
For aviation fuel mixtures, the temperature at which the last ice crystal disappears as the fuel warms. Hydrocarbon mixtures do not freeze like pure water at one sharp temperature.
Why temperature and pressure matter
Increasing temperature generally increases volatility. Reducing ambient pressure also encourages vaporisation. A fuel line containing warm, low-pressure gasoline may therefore form a vapour bubble. If the bubble collects at a bend or high point in the pipe, it can restrict or stop liquid flow.
Density, specific gravity and fuel mass
Octane quality and detonation resistance
For piston-engine gasoline, the octane rating describes resistance to abnormal combustion (detonation) under specified test conditions. It is not a direct measure of the energy contained in a litre of fuel, nor does a higher grade automatically make an engine produce more power. The engine must be approved for that grade. Using a fuel with inadequate anti-knock quality can cause detonation, excessive cylinder-head temperature and potentially severe engine damage.
Why a fuel's freezing point matters to a jet
At high altitude, wing-tank fuel can become very cold because of prolonged exposure to low outside-air temperatures. Wax crystals may form as the fuel approaches its specification freezing point. These crystals can accumulate on filters or restrict small passages. The relevant limit is the approved fuel specification and aircraft operating limitation—not a generic temperature remembered from another aircraft type.
3. Aviation Gasoline — Avgas
Avgas was developed for piston aero engines, initially carburetted engines. Compared with kerosene, it has a lower density, higher volatility and higher vapour pressure. It vaporises readily, which assists starting, but also makes it more susceptible to vapour lock as temperature rises or ambient pressure falls.
Grades of Avgas in the source
| Grade | Colour in source | Typical use / significance |
|---|---|---|
| 80 grade | Red | Lower-powered, lower-compression, normally aspirated carburetted engines. The grade number indicates octane rating and resistance to detonation. |
| 100 grade | Green | Higher-powered / higher-compression engines; tetraethyl lead improves resistance to detonation. |
| 100LL | Blue | Same octane rating as 100 grade but with lower lead content; widely used for higher-powered injected or boosted piston engines. |
Avgas has a flash point of approximately −40°C in the source and a required freezing point of −58°C or lower. Because of its high vapour pressure, rapid climb after a hot soak can increase boil-off and may contribute to vapour-lock conditions.
Static dissipaters
Fuel moving through pipes and filters made from dissimilar materials can accumulate an electrical charge faster than it can dissipate. A spark from charged fuel can ignite the fuel-air vapour above it, particularly when fuel splashes or forms a mist. Static-dissipater additives reduce this hazard. Correct bonding and earthing during refuelling remain essential; additives do not replace safe procedures.
Chemical stability
During storage, light hydrocarbons can evaporate and the fuel can oxidise. The source identifies soluble gums, insoluble black particulates and oxidised lead compounds as potential deposits. These can block filters, carburettor jets and narrow-bore pipes.
Detonation, pre-ignition and incorrect fuel
Incorrect or contaminated fuel can contribute to poor engine operation. If the approved fuel grade is unavailable, the pilot must not improvise a substitution based on colour or apparent similarity. The AFM/POH and approved engine documentation determine acceptable fuel grades and any limitations.
4. Aviation Kerosene — Avtur
Avtur was developed from paraffin for gas-turbine engines. It is denser and less volatile than Avgas, with a lower vapour pressure (approximately 0.14 psi in the source). Its higher flash point reduces some handling risks, but low-temperature behaviour is important: viscosity rises as the fuel cools, making it harder to pump and reducing flow.
Kerosene is a mixture of hydrocarbons, each with its own freezing point. As temperature falls, the higher-freezing components form waxy crystals; further cooling increases the wax content and viscosity. The source notes that kerosene remains pumpable to approximately 6°C below its freezing point, after which continued cooling can produce slush and eventually a semi-solid waxy mass.
Grades of Avtur
| Grade | Characteristics in the source |
|---|---|
| Jet B | Wide-cut blend described as 70% gasoline and 30% kerosene. Higher vapour pressure, low flash/fire point, low freezing point, lower specific gravity and reduced lubricity. The source associates it with arctic use, such as Alaska and Canada. |
| Jet A | Straight kerosene; flash point 38°C and freezing point −40°C. Described as normally used for domestic flights in the USA. |
| Jet A-1 | Straight kerosene with a lower freezing point of −47°C in the source; described as the preferred commercial aviation kerosene worldwide. |
Avtur must also provide suitable lubricating properties because it passes through high-pressure pumps and fuel-metering equipment before being atomised by engine injectors. Long storage in conditions that permit oxidation can still create gums and particulates.
Low-temperature fuel management in operation
Jet fuel temperature is monitored because cold fuel can approach its freezing-point limit during long, high-altitude flights. The flight crew may consider fuel temperature together with outside-air temperature, time at altitude, fuel quantity and the aircraft's approved operating guidance. Descent into warmer air can increase fuel temperature, but crews must use the aircraft's published procedures rather than assume that a particular manoeuvre or altitude change is always appropriate.
Fuel also acts as a hydraulic working fluid for engine fuel-control equipment and as a lubricant for some fuel-wetted components. Poor lubricity, contamination or incorrect fuel specification can therefore affect more than combustion alone.
5. Fuel Contamination
Water contamination
Fuel can absorb moisture from the atmosphere. Warm fuel can support more dissolved moisture than cold fuel. As fuel cools, dissolved water may precipitate and collect as free water at the bottom of the tank.
Very small water particles held within the fuel. It cannot be removed by ordinary tank draining and may contribute to icing in the induction system.
Water that has separated from the fuel or entered in bulk. Because it is denser, it settles at low points and can be removed through suitable drains.
Tank ventilation is necessary as fuel is consumed. It prevents a partial vacuum and maintains the pressure conditions needed for fuel flow. The source notes that a full tank reduces the air space in which moisture-laden air can collect, although actual storage and dispatch practices must follow the aircraft maintenance and operating instructions.
Fungal contamination
Water sediment checks — clear and bright
- Take samples from the lowest drain point of each tank and from applicable fuel filters.
- Collect the sample in a clear container and inspect it against a good light source.
- If haze clears from the bottom upwards, the source attributes it to air bubbles entrained during sampling. Haze that remains or clears from the top downwards indicates entrained water.
- If water or sediment is found, continue draining the affected tank or filter until a pure fuel sample is obtained, following the aircraft procedure.
Other contamination mechanisms
Filters, bypass and differential-pressure indication
A filter traps particles above its rated filtration size. As contaminants accumulate, resistance to flow rises and the pressure drop across the element increases. Some installations use a differential-pressure switch or indicator to warn that the filter is becoming restricted. Certain designs incorporate a bypass to preserve fuel flow if the filter becomes excessively blocked. A bypass protects continuity of supply, but it may allow unfiltered fuel downstream; it is not a sign that the system is healthy.
6. Fuel Tank Construction and Associated Features
Three principal tank types
| Type | Construction | Advantages / limitations |
|---|---|---|
| Rigid tank | A separate, self-supporting tank, historically often externally mounted. | Simple concept, but adds mass and requires surrounding structure to carry tank and fuel acceleration loads. Large tanks can be difficult to install or replace. |
| Flexible tank | Fuel-resistant rubberised fabric fitted within an airframe cavity; sometimes called a bladder tank. | Can fit irregular spaces and may be lighter than a comparable rigid tank. Can be more crashworthy if not punctured. Wrinkles can trap water; leaks may track along internal structure before becoming visible. |
| Integral tank | A sealed part of the aircraft structure, commonly a wing box. | Uses existing structure and provides high capacity with less separate tank mass. Requires sealing, access for inspection and careful control of leaks and corrosion. |
Flapper valves, stack pipes and sumps
Flapper valves can help control fuel movement between tank compartments and preserve usable fuel around the pickup during manoeuvres. The stack pipe draws fuel from above the tank bottom, leaving a specified unusable quantity so that water and debris at the bottom are less likely to enter the engine supply. A coarse finger strainer protects the pipe inlet from larger debris.
A sump is a low point where free water can collect. Water drain valves allow the pilot or maintenance personnel to sample and drain it. The source describes a spring-loaded drain cock that is pushed to open; after sampling, it must seat correctly and stop the flow.
Venting and filler points
Light-aircraft tanks are vented so that air replaces the fuel drawn off. A blocked vent can create a pressure differential that restricts flow or damages the tank. Filler caps must seal against leakage; recessed filler areas need drains that discharge clear of the aircraft. Fuel grade and minimum grade markings must be visible at the filling point. Bonding provisions are required for the aircraft and ground fuelling equipment.
Internal tank management: baffles, collector bays and surge tanks
Integral tanks and structural sealing
Fuel tank access and maintenance are controlled tasks. Entry into a tank introduces confined-space, toxic-vapour, oxygen-deficiency, fire and explosion hazards. Only trained personnel using approved maintenance data, permits, atmospheric monitoring and rescue arrangements may perform tank entry.
7. Fuel Systems for Light Aircraft
Gravity-feed system — typical high-wing single
Where the fuel tanks are sufficiently above the carburettor, gravity provides the pressure head needed to deliver fuel. The source states that the system is designed to supply the carburettor float chamber at 1.5 times the flow required by the engine at take-off power. A selector permits both tanks, either tank individually, or OFF to be selected. Tank vents and a balance pipe support ventilation. A gascolator/fuel strainer removes fine particles and free water upstream of the carburettor.
Primer pump and selector precautions
A hand-operated primer can draw fuel from the gascolator and deliver it near the cylinder inlet for cold starting. It works by a pull-to-fill and push-to-deliver action. If its plunger is not locked closed, manifold suction may draw fuel through it and cause the primed cylinders to run rich.
The source lists selector requirements for JAR 23 aircraft: the pilot must be able to see and operate it in flight; each engine must be isolatable; OFF requires a separate distinct action; tank and OFF positions are marked and detented; the selector must not pass through OFF when changing tanks; and the handle must indicate the selected position.
Pressure-feed system — typical low-wing single
When the engine is above or level with the tanks, gravity head is insufficient or unreliable through normal attitudes. An engine-driven mechanical pump draws fuel from the tanks and supplies it under pressure. An electrically driven auxiliary pump is fitted in parallel as a backup and is selected for take-off, landing, tank changes, low fuel-pressure indications or rough running, in accordance with the aircraft checklist.
For a simple illustration, if fuel density is 720 kg/m³ and the vertical head is 0.8 m, the theoretical pressure head is approximately 720 × 9.81 × 0.8 = 5,650 Pa (5.65 kPa), before line losses. This explains why tank height matters, but actual system performance must be taken from the aircraft design and approved data.
Fuel pressure and flow indications
A pressure gauge is connected near the carburettor or injector inlet and shows the delivery pressure against marked minimum and maximum limits. The source gives 0.5–8.0 psi as a typical range for a normally aspirated light piston engine. More complex aircraft may combine pressure and flow indications. A split between twin-engine needles can reveal unequal operating conditions.
Vapour lock and light twins
Cross-feed permits fuel from one side to supply the opposite engine, helping manage fuel imbalance or respond to a system problem. The source cautions against take-off with cross-feed selected, against landing with cross-feed selected under normal circumstances, and against selecting cross-feed on both sides simultaneously because fault diagnosis becomes difficult.
Light-aircraft fuel quantity indications
A float sender moves a wiper across a resistance winding. The changing resistance or voltage is converted into a quantity indication. This is a volume-based method and is most accurate when stationary on the ground or in straight-and-level, unaccelerated flight. Acceleration, turning and pitch changes move the fuel in the tank and can produce misleading readings. A calibrated red line/radial identifies empty usable fuel; a power-off position may be provided.
Fuel-system components and what each one contributes
| Component | Function | What a problem may cause |
|---|---|---|
| Fuel selector | Connects the engine feed to the selected tank or shuts fuel off. | Incorrect selection or internal restriction can interrupt supply. |
| Finger strainer / tank outlet screen | Stops relatively large debris before it enters the line. | Debris accumulation can restrict flow at the tank outlet. |
| Gascolator / fuel strainer | Provides filtration and a low point where water can collect for draining. | Water or sediment can block the bowl or downstream passages. |
| Engine-driven pump | Provides the pressure needed to feed the carburettor or injection system. | Failure may cause low pressure or fuel starvation. |
| Auxiliary electric pump | Provides backup or supports defined operating phases and tank changes. | Electrical failure removes the backup function. |
| Vent line | Allows air to replace fuel consumed and accommodates pressure changes. | A blocked vent can create a vacuum and progressively restrict flow. |
Fuel flow and pressure are not the same indication
Worked example — diagnosing a possible vent restriction
A low-wing aircraft initially runs normally after take-off. After some time, engine power begins to reduce and fuel pressure falls. Selecting the auxiliary pump does not restore normal operation. A blocked tank vent is one possible cause: as fuel leaves the tank, the pressure inside falls, increasing the suction required to draw fuel. The pilot must use the aircraft checklist and land as required; this example illustrates a system principle, not a troubleshooting checklist.
8. Fuel Quantity Measurement
Resistance / float gauging
The float follows the fuel surface. Its arm moves a wiper over a coil winding, changing circuit resistance or output voltage. The instrument is calibrated in units of volume. Because the float senses a local fuel level, it is affected by fuel movement during manoeuvres and by tank geometry.
Capacitive fuel-contents measurement
Large aircraft use a system that measures fuel contents by exploiting the different dielectric properties of air and fuel. Each tank unit contains two concentric tubes separated by insulation. As fuel level changes, the effective capacitance changes. Several tank units are connected in parallel, and a reference/compensator unit remains submerged to account for changes in fuel characteristics. An amplifier converts the electrical signal into a fuel-contents indication.
Capacitance depends on plate area, separation and the dielectric material between the plates. Since the fuel level changes the proportion of the probe surrounded by fuel rather than air, total capacitance changes. This provides a more useful indication of fuel contents than a simple float in a large tank where fuel volume changes with temperature.
Capacitance probes — why the reading changes
A capacitance probe is formed by two conductive surfaces separated by an insulating gap. Together they behave as a capacitor. As fuel level rises, more of the probe is surrounded by fuel rather than air. Because fuel and air have different dielectric properties, the capacitance changes. Electronic circuitry converts the measured capacitance into a fuel-quantity signal.
Several probes may be distributed through a tank because a single probe cannot accurately represent the total contents when the tank has an irregular shape or when the aircraft is not level. A compensator can account for changes in fuel dielectric characteristics. The system may then calculate a total quantity and display it as mass or volume, depending on the aircraft design.
Why quantity indications can disagree
- Aircraft attitude changes the distribution of fuel within a tank.
- Electrical faults, wiring resistance, probe contamination or calibration errors can affect the signal.
- Fuel density changes with temperature, so volume and mass are not interchangeable without a density basis.
- On the ground, a calibrated physical quantity check may be available as an independent cross-check on certain aircraft.
For dispatch and fuel planning, pilots reconcile indicated quantity with uplift records, calculated fuel, operational checks and the aircraft's approved procedures. A cockpit gauge should not be treated as an infallible substitute for proper fuel planning.
9. Large-Aircraft Fuel Systems
Tank layout and dry bays
Transport aircraft commonly use integral wing tanks. A centre tank increases capacity for longer-range flights, and auxiliary tanks may be installed in the fuselage. Some high-performance or supersonic aircraft use rear or tailplane tanks for fuel trimming. The fuel-system boundary in the source is the low-pressure fuel cock; the engine high-pressure system is covered in powerplant material.
A dry bay is a ventilated, drained void between a fuel tank and a fire-zone structure. It prevents a leaking tank from placing fuel directly against a structure exposed to flames. Integral tanks need access panels for internal inspection. Tank sumps collect water and must be drainable; the source gives a minimum effective sump capacity of the greater of 0.10% of tank capacity or one-quarter litre for the stated large-aircraft context.
Centre tank management
Because centre-tank fuel adds mass to the fuselage, operators commonly use centre/auxiliary fuel before wing fuel, subject to the aircraft’s approved fuel policy and limitations. Keeping fuel in the wings can help maintain the intended wing bending-load distribution. Centre-tank loading may be limited unless wing tanks are filled, depending on aircraft design.
Tank pressurisation, venting and surge tanks
Some large-aircraft tanks are slightly pressurised using regulated engine bleed air. This helps reduce evaporation at altitude and provides positive pressure at booster-pump inlets. Relief valves vent excess pressure; inward relief valves admit ambient air if fuel draw-off exceeds the regulated supply, preventing negative pressure that could damage the tank or restrict flow.
Vent-surge tanks sit outboard of the main tanks and connect them to atmosphere. They accommodate thermal expansion and help prevent fuel escaping through the vents during a bank. Fuel collected in a surge tank is returned to the main tank by a pump, jet pump or other arrangement.
Why tank layout is more than a storage decision
Tank position influences structural loading, lateral balance, longitudinal centre of gravity, pump installation, protection from damage and the ability to maintain a reliable supply. Wing tanks place fuel near the wings' lift-producing structure and can reduce wing bending loads in some conditions. Centre tanks provide additional capacity near the fuselage, but their fuel may need to be used in a defined sequence to maintain the approved balance and loading limits.
Some aircraft divide a wing tank into inner and outer compartments. Baffle ribs and one-way flapper valves control movement so that fuel tends to remain available to the feed region. A dry bay is a region intentionally kept free of fuel around certain systems or structural penetrations, helping limit the consequences of a leak. Exact arrangements are aircraft-specific.
Tank venting and pressure management
As fuel is consumed, air must enter the tank system. During refuelling, displaced air must escape. During temperature changes, fuel and ullage volume expand or contract. Venting therefore protects the tank from excessive positive or negative pressure and supports predictable pump operation. Surge/vent tanks provide a buffer for fuel that reaches the vent line during manoeuvres or expansion. Vent outlets are designed to reduce water ingestion and other hazards while maintaining the required airflow.
10. Twin-Jet Fuel Supply and Components
The source breaks down a twin-jet schematic into its components. The key design aim is to supply each engine with the required fuel flow and pressure through intended manoeuvres, while preserving a backup route if a pump or tank becomes unavailable.
Normal supply and cross-feed
In the simplified arrangement, each engine normally receives fuel from its own wing tank and the centre tank. Low-pressure (LP) booster pumps supply fuel to the engine feed line. Cross-feed allows the opposite wing tank to supply an engine when needed for imbalance correction or abnormal operation. The source describes higher output pressure from centre-tank booster pumps so that centre-tank fuel is used first when all pumps are selected ON; when the centre tank is depleted or a pump fails, wing-tank supply takes over without interruption.
Booster pumps and related devices
Fuel cocks, filters and temperature
The low-pressure fuel cock isolates the airframe fuel supply to the engine. The high-pressure fuel cock belongs to the engine-side system. Fuel filters remove contamination before it reaches sensitive equipment. Fuel temperature indication is important because low temperature can approach freezing limits, while high temperature can contribute to vapour formation in susceptible systems.
Flight-deck fuel control panel and APU supply
The flight-deck panel provides the crew with the controls and indications needed to manage pumps, valves, cross-feed, transfer and jettison functions. The auxiliary power unit may have a dedicated fuel supply path, including an APU fuel shut-off valve and pump arrangement. Always use the aircraft’s actual panel logic and checklist; generic descriptions cannot replace type-specific procedures.
Pressure refuelling gallery
Large aircraft commonly use a single-point pressure-refuelling connection. Fuel enters through a refuelling coupling and is distributed through gallery pipes to selected tanks. Valves and automatic shut-off devices control filling. The system supports faster, controlled refuelling than opening individual tank filler caps. Fuel imbalance on the ground can be corrected by controlled transfer or refuelling procedures.
From tank to combustor: a representative turbine-engine flow path
A typical transport-aircraft arrangement uses low-pressure (LP) booster pumps in the tanks to deliver fuel to the engine feed line. A low-pressure shut-off valve can isolate the engine supply. Fuel then passes through aircraft and engine filtration stages, reaches an engine-driven high-pressure pump, and is delivered to the fuel metering/control unit. The metering unit schedules the correct fuel flow for engine operating conditions before the fuel is distributed to the burners through manifolds and nozzles.
The high-pressure pump is driven by the engine and supplies the pressure required by the fuel-control and injection system. The LP booster pumps provide positive inlet pressure and help prevent cavitation or vapour formation at the high-pressure pump inlet. The exact pump count and flow arrangement vary by engine and airframe.
Important valves and devices
| Device | Purpose |
|---|---|
| Low-pressure fuel shut-off valve | Isolates the aircraft fuel supply to an engine. |
| High-pressure fuel shut-off valve | Provides engine-level isolation as part of the engine fuel control and fire protection architecture. |
| Cross-feed valve | Connects one side's fuel supply to the opposite engine feed when the approved procedure requires it. |
| Non-return valve | Prevents reverse flow into a line or tank when pressure conditions change. |
| Pressure switch | Detects whether pressure is above or below a set threshold and can trigger a warning or logic input. |
| Ejector / jet pump | Uses motive fuel flow to entrain and move fuel without a conventional electric motor at the pickup point. |
Cross-feed is not the same as fuel transfer
Fuel heating and temperature measurement
Some turbine-engine installations use a fuel-oil heat exchanger. Hot engine oil transfers heat to cold fuel, helping protect fuel-system components from ice formation while also cooling the oil. Fuel temperature probes allow the crew or control system to monitor fuel temperature against aircraft limits. The exchanger is not a substitute for monitoring the published minimum fuel temperature.
11. Refuelling, Defuelling and Ground Reconciliation
Fuel imbalance on the ground
Before dispatch, fuel quantity and distribution must agree with the required loading condition. An imbalance can affect lateral centre of gravity and handling. The source shows that LP pumps and the refuelling gallery can be used in a controlled arrangement to reconcile imbalance. The actual procedure must come from the aircraft maintenance/operations documentation.
Defuelling
For the large-aircraft arrangement described, LP pumps can be used to defuel a single tank or the aircraft. The bowser is connected to the defuel point while refuel valves remain closed. The source gives a maximum suction pressure of −5 psi to avoid damaging the fuel system. Defuelling removes usable fuel; unusable fuel is removed through the water drain valves.
Fuel reconciliation without electrical power
The source states that a physical fuel quantity check must be possible on the ground without applying electrical power. A drip stick is one example. It is a hollow calibrated tube with a small side orifice. The tube is lowered until fuel produces a steady drip, indicating that the orifice is at the same level as the fuel surface. The quantity is read from graduations; several readings may be added to obtain the total for a tank.
Overwing and pressure refuelling
Bonding, earthing and ignition control
- Verify aircraft identity, fuel grade and required quantity against the approved documentation.
- Position and secure the fuelling equipment using the airport/operator procedure.
- Establish the required bonding/earthing connections before opening the fuel system.
- Control ignition sources and comply with exclusion zones and communications requirements.
- Monitor the fuelling process, quantity, tank selection and any leakage or abnormal indication.
- Close and secure caps, panels and couplings; check for leakage and reconcile uplifted fuel against the aircraft record.
12. Fuel Jettisoning
Some transport aircraft have a maximum take-off mass significantly greater than maximum landing mass. If an emergency requires a landing soon after take-off, the aircraft may be above its permitted landing mass. Fuel jettisoning can reduce mass before landing, subject to aircraft limitations, weather, airspace and operational procedures.
Design and operating principles
- Fuel must discharge clear of the aircraft so that fuel or fumes do not enter the structure or create a fire hazard.
- Controllability must not be adversely affected.
- The system must prevent a hazardous result from a single failure, including unsafe asymmetrical jettisoning.
- The crew must be able to stop jettisoning at any time.
- Automatic shut-off protects the required minimum fuel quantity; the source describes a minimum for climb and subsequent cruise.
- Controls are coloured red and protected against inadvertent operation.
The source distinguishes JAR 23 and JAR 25 requirements. It describes a JAR 23 twin-engine case with a jettison rate averaging 1% of MTOM per minute, subject to the stated minimum-time condition. For JAR 25 aircraft, a system is required unless the aeroplane can meet specified climb requirements at the relevant reduced fuel mass. These are historical syllabus/regulatory references in the source; current certification and operational requirements must be checked against current authority material and the aircraft AFM.
Jettison versus dumping, defuelling and fuel burn
Fuel jettisoning is an installed in-flight system designed to discharge fuel in a controlled manner. It is different from ground defuelling, which uses approved ground equipment to remove fuel, and different from simply continuing flight to burn fuel. Not all aircraft have a jettison system; aircraft without one must follow their approved landing-mass and overweight-landing procedures.
When jettison is available, the crew considers the required landing mass, the time and altitude needed, the jettison rate, minimum fuel protection, weather and ATC coordination. Fuel is discharged from designated outlets, often near the wingtips or other approved locations, to keep the plume clear of engines and the airframe. The system is designed to prevent unsafe asymmetry and to allow the crew to stop the operation.
13. Fuel Trimming
Some large transport and supersonic aircraft use fuel transfer to alter the aircraft’s centre of gravity. Fuel can be moved from the main tanks to rear-fuselage or tailplane tanks, shifting the CG aft. This can reduce the elevator or tailplane deflection needed in some flight conditions and reduce trim drag.
The source notes that fuel trimming can be particularly useful at low airspeeds, such as approach, where preserving control range is valuable. At high altitude and transonic speeds, trimming can reduce the need for large aerodynamic trim deflections. Concorde is cited as an example of a supersonic aircraft using fuel transfer to manage CG and help counter Mach tuck.
Centre-of-gravity principle and a simple example
The longitudinal centre of gravity is the balance point of the aircraft's total mass. Moving fuel changes the distribution of mass and therefore the aircraft's total moment. A simplified relationship is:
For a conceptual example, imagine 1,000 kg of fuel transferred from a tank whose arm is 10 m to a tank whose arm is 15 m aft of the datum. The transfer changes the total moment by 1,000 × (15 − 10) = 5,000 kg·m, while total fuel mass remains unchanged. The CG shift depends on the aircraft's total mass and approved datum/arm conventions. This is a teaching example only; real aircraft CG calculations use approved loading data and limits.
Fuel trimming is therefore a mass-management function, not simply a way to empty one tank first. Automatic transfer logic may be scheduled by flight phase, speed or CG target, and may include restrictions to prevent the aircraft moving outside its approved envelope.
14. Chapter Summary — Key Takeaways
- Fuel volatility, vapour pressure, flash point, fire point, auto-ignition temperature and freezing behaviour affect safe operation and system design.
- Avgas is relatively volatile and is used in piston engines; the source lists 80, 100 and 100LL grades. Avtur is less volatile, denser and has important low-temperature viscosity/freezing characteristics.
- Static charge during fuelling can ignite fuel vapour. Static dissipaters, bonding and earthing are separate layers of protection.
- Water may be dissolved or free. Free water collects at low points; microbial contamination can block filters and contribute to corrosion.
- Clear-and-bright checks identify visible sediment, haze and free water. Samples should be taken from tank and filter low points.
- Rigid, flexible and integral tanks have different mass, installation, inspection and leakage characteristics.
- Stack pipes, finger strainers, sumps, drain valves, vents and flapper valves protect usable fuel supply and system integrity.
- High-wing light aircraft may use gravity feed; low-wing aircraft commonly use engine-driven pumps with an electric auxiliary pump.
- Light-aircraft float gauges indicate level/volume and can be inaccurate during manoeuvres. Large aircraft commonly use capacitive fuel-contents measurement.
- Large aircraft use wing, centre and sometimes auxiliary tanks, with vent-surge tanks, pressurisation, booster pumps, cross-feed, filters and protective valves.
- Fuel jettisoning can reduce mass before an emergency landing; fuel trimming moves the CG by transferring fuel between tanks.
- Open-line refuelling requires correct fuel identification, bonding/earthing, control of ignition sources and prevention of splashing. Type-specific procedures always take precedence.
Essential distinctions to remember
| Do not confuse | Difference |
|---|---|
| Flash point vs fire point | Flash point supports momentary ignition; fire point supports sustained combustion. |
| Dissolved vs free water | Dissolved water is held in the fuel; free water separates and settles. |
| Gravity feed vs pressure feed | Gravity uses tank height; pressure feed uses pumps to deliver fuel. |
| Cross-feed vs transfer | Cross-feed changes which tank supplies an engine; transfer moves fuel between tanks. |
| Float vs capacitive gauging | Float senses local level; capacitance changes with the dielectric medium around the probes. |
| Fuel jettison vs defuel | Jettison is an in-flight mass-reduction system; defuelling is a ground servicing operation. |
Putting the whole system together
Think of the fuel system as a continuous chain. Fuel is stored in tanks whose construction and internal geometry keep usable fuel available. Vents allow the tank to breathe. Pickups, sumps and strainers protect the inlet. Gravity or pumps establish delivery pressure. Filters remove contamination. Valves select, isolate or redirect the flow. Engine-driven pumps and metering equipment provide the pressure and quantity required by the engine. Indications tell the crew what is available and whether the system is operating normally. Refuelling and maintenance procedures preserve the integrity of the whole chain.
Revision checklist
- Can you explain why fuel density and temperature matter to aircraft mass calculations?
- Can you distinguish Avgas from Avtur and explain the significance of grade and freezing point?
- Can you describe dissolved water, free water and microbial contamination?
- Can you compare rigid, bladder and integral tanks?
- Can you explain the roles of vents, sumps, stack pipes, baffles, collector bays and surge tanks?
- Can you trace fuel flow through gravity-fed and pump-fed light-aircraft systems?
- Can you explain float and capacitance fuel-quantity measurement?
- Can you trace a representative transport-aircraft fuel path and explain booster pumps, cross-feed and shut-off valves?
- Can you distinguish pressure refuelling, defuelling, jettisoning and fuel trimming?
- Can you identify which information must always come from the aircraft's approved manuals and checklists?
15. Knowledge Check
Choose the single best answer for each question. The quiz contains 12 questions based on this chapter. Select one answer per question, then use Check answers to see your score.
Further study
Regulatory references in standard training material include JAR 23 and JAR 25. They are retained as part of the source’s syllabus framing; consult current applicable regulations for present-day compliance.