AEROLEARN RWANDA/Aircraft General Knowledge/Chapter 9
AeroLearn Rwanda · Aircraft General Knowledge

Chapter 9 — Hydraulics

How aircraft generate, transmit, control and use hydraulic power — from Pascal’s law and simple actuators to transport-aircraft systems, emergency power and hydraulic protection.

ATPL foundation12-question knowledge checkStudy notes · Rev 1
Start here

1. Introduction and learning objectives

Hydraulic power enables a pilot to operate services that require substantial force without having to apply that force directly at the point of use. On large aircraft, hydraulic systems may power the flying controls, flaps, landing gear, spoilers and wheel brakes.

The chapter describes a system in which a virtually incompressible fluid is passed through a network of pipes to actuators. The actuators convert fluid pressure into mechanical force and movement. The chapter then develops the principles behind this arrangement and examines the components and circuits that make it work.

Central idea: a pump supplies fluid flow; resistance to that flow produces pressure; valves control where the fluid goes; actuators convert the pressure and flow into useful movement.

By the end of this chapter, you should be able to:

  • Explain potential energy, kinetic energy, static pressure and Pascal’s law.
  • Calculate force, area, pressure, displaced volume and actuator movement.
  • Compare single-acting, double-acting unbalanced and balanced actuators.
  • Explain selector valves, NRVs, hydraulic locks and hand pumps.
  • Distinguish passive, active, open-centred and closed-centred systems.
  • Describe gear, vane, fixed-displacement piston and variable-displacement pumps.
  • Explain pressure regulation, filtration, accumulators, reservoirs, fluids and seals.
  • Describe priority valves, PTUs, RATs, flow controls and emergency supply arrangements.

How the complete system fits together

Generation

Reservoir, pump, drive, suction line and case drain.

Conditioning

Filters, accumulator, pressure regulator, cooler and relief valves.

Distribution

Pressure/return lines, selector valves, NRVs, priority and sequence valves.

Utilisation

Flight-control actuators, landing-gear jacks, flap drives, brakes and hydraulic motors.

1. GENERATEPump + reservoir2. CONDITIONFilter + regulate3. DISTRIBUTEValves + pipes4. USE POWERJack or motor

2. Basic physics of hydraulics

Fluids and practical incompressibility

For the pressures covered in standard training materials and their JAR-FCL learning objectives, fluids are treated as incompressible. In practical terms, a liquid does not reduce its volume appreciably when pressure is applied. This allows movement at one point in a closed hydraulic circuit to transmit pressure to another point.

This is an engineering approximation, not a claim that liquids are perfectly incompressible under every conceivable condition. Entrained air is especially important: unlike the liquid, gas compresses significantly and can make a hydraulic system feel spongy or behave unpredictably.

Potential and kinetic energy

Potential energy

Fluid stored at a height or under static pressure has stored energy. The source text uses water held behind a dam to illustrate this concept.

Kinetic energy

Fluid in motion possesses energy associated with its movement. The source illustrates this with water flowing from the reservoir.

Static pressure and depth

Static pressure in a fluid column increases with depth. The source demonstrates that containers of different shapes but equal fluid depth produce the same pressure at their bases. The shape of the container does not change the pressure at a given depth; the vertical fluid column is the key factor.

Operational link: the pump inlet must receive a reliable supply of fluid. Low inlet pressure, air ingestion or cavitation can interrupt pump delivery and reduce hydraulic performance.

Why entrained air is a problem

The liquid is treated as incompressible in the basic calculations, but air trapped in the fluid is compressible. When a control is selected, some pump displacement may compress the trapped air instead of immediately moving the actuator. The result can be delayed response, springy or spongy operation, noise and irregular movement. Air may also promote foaming and reduce the reliability of the pump inlet supply. This is why bleeding, de-aeration and reservoir design matter.

Worked example — static head: For a water-like fluid, pressure due to a vertical column is approximately \(p = rho x g x h\). Taking density as 1,000 kg/m³, \(g=9.81\\,m/s²\) and depth \(h=2\\,m\), pressure is \(1,000×9.81×2=19,620\\,Pa\), or about 19.6 kPa. This illustrates the depth principle; actual hydraulic-fluid density varies by fluid type.

3. Pascal’s law, force, area and pressure

Pascal’s law states that pressure applied to an enclosed fluid is transmitted equally throughout the fluid and acts in all directions, at right angles to the container walls. This is why a force applied to one piston can produce a force at another piston elsewhere in the circuit.

Pressure = Force ÷ Area   |   P = F ÷ A
Force = Pressure × Area   |   F = P × A
Area = Force ÷ Pressure   |   A = F ÷ P

Pressure cannot be increased in a hydraulic system merely by moving fluid freely. The pump moves a volume of fluid into a system where resistance to flow exists. The resulting pressure acts throughout the enclosed fluid.

Units and conversions

QuantitySI unitImperial unit
ForceNewton (N)Pound-force (lbf)
AreaSquare metre (m²)Square inch (in²)
PressurePascal (Pa), N/m²Pounds per square inch (psi)

The source notes give 1 bar ≈ 14.504 psi and 1 bar = 100.0 kPa. One psi is approximately 6,894.757 Pa. Always keep units consistent before substituting into a formula.

Worked example 1 — pressure: A force of 100 lbf acts on a piston with an area of 10 in². Pressure = 100 ÷ 10 = 10 psi.
Worked example 2 — force: A hydraulic pressure of 3,000 psi acts on a piston area of 2 in². Force = 3,000 × 2 = 6,000 lbf (ideal calculation, before friction and losses).
FORCEAREAPRESSURE

Understanding the pressure triangle

Use the relationship as a three-way calculation rather than memorising three unrelated equations. If force and area are known, divide to obtain pressure. If pressure and area are known, multiply to obtain force. If force and pressure are known, divide to obtain area.

Check units first

For psi, use pounds-force and square inches. For pascals, use newtons and square metres. Do not multiply a force in newtons by an area in square inches and call the result pascals.

Absolute vs gauge pressure

Aircraft system diagrams and normal cockpit hydraulic indications commonly refer to system pressure relative to the surrounding pressure. Always follow the definition used in the question or aircraft data.

Worked example — SI pressure: A 4,000 N force acts on a piston area of 0.002 m². Pressure = 4,000 ÷ 0.002 = 2,000,000 Pa = 2 MPa = 20 bar.

4. Transmission of power and multiplication of force

If two equal-area pistons are connected by a pipe, an input force on one piston produces an equal output force at the other, assuming ideal conditions. This transmits force but does not multiply it.

Force multiplication is achieved by applying the input force to a small piston and allowing the resulting pressure to act on a larger piston. The pressure is equal throughout the enclosed fluid, but the larger output area produces a greater force.

Bramah’s press — the source example

The example applies 20 lbf to a 2 in² input piston, producing 10 psi. That pressure acts on a 20 in² output piston, producing 200 lbf.

Input pressure = 20 ÷ 2 = 10 psi
Output force = 10 × 20 = 200 lbf

The output force is ten times the input force, but the output piston travels only one tenth of the input stroke. The input piston moves 5 inches and displaces 10 in³ of fluid. The output piston has an area of 20 in², so its stroke is 10 ÷ 20 = 0.5 inch.

Volume = Length × Area   |   V = L × A
Input work ≈ output work: F₁ × d₁ = F₂ × d₂
Worked example 3 — actuator stroke: An input piston of 3 in² moves 4 inches. Displaced volume = 3 × 4 = 12 in³. If the output piston area is 12 in², output travel = 12 ÷ 12 = 1 inch.
Exam principle: force multiplication is accompanied by reduced output movement for the same displaced fluid volume. It does not create energy; ideal input work equals ideal output work.

Displacement, speed and power — three different ideas

Pressure determines the force available at a given piston area. Flow rate determines how quickly a volume of fluid is delivered and therefore how quickly an actuator moves. Power is the rate at which work is done. A system may have high pressure but insufficient flow to move a large actuator quickly; conversely, high flow at low pressure may move a component quickly but may not produce enough force to overcome its load.

Actuator speed = Flow rate ÷ Effective piston area
Hydraulic power (ideal) = Pressure × Volumetric flow rate
Worked example — hydraulic power: A system supplies 3,000 psi at 2 US gal/min. Using the common approximation \(HP≈(PSI×GPM)/1714\), ideal hydraulic power is about 3,000×2÷1,714 = 3.50 hp. Actual shaft input must be higher because pumps and drives are not 100% efficient.

5. Linear actuators

Linear actuators (also called jacks) convert fluid pressure and flow into straight-line force and movement. The chapter identifies three types.

TypeConstruction and operationKey result
Single-actingHydraulic pressure moves the piston in one direction; a spring or other mechanical force returns it.One hydraulic port; powered in one direction.
Double-acting unbalancedOne ram is attached to one side of the piston. Effective piston areas differ on the two sides.For equal pressure, extension force is greater than retraction force.
Double-acting balancedEqual-area rams are attached to both sides of the piston.For equal pressure, extension and retraction forces are equal.

Why the unbalanced actuator has unequal forces

On the full piston face, pressure acts over the full bore area. On the ram side, the ram occupies part of the piston area, reducing the effective area on which pressure acts. Since force = pressure × effective area, the ram-side force is lower for the same pressure.

Worked example 4 — unbalanced actuator: Bore area = 8 in²; ram area = 2 in²; system pressure = 2,500 psi. Extension force = 8 × 2,500 = 20,000 lbf. Retraction force = (8 − 2) × 2,500 = 15,000 lbf. Ideal values, excluding friction.

A balanced actuator can be useful where equal force in both directions is required, where a loop of cable is moved, or where two items are operated in opposite directions simultaneously.

Actuator geometry — visual comparison

Single-actingDouble-acting unbalancedDouble-acting balancedOne pressure portOne ram; unequal effective areasEqual-area rams on both sides Return movement by spring or external forceExtension force greater than retraction forceEqual force in both directions at equal pressure

6. Ports, selector valves and hydraulic lock

A port is an entry into or exit from a hydraulic component. A single-acting actuator normally has one port; a double-acting actuator has two. Selector valves direct fluid into and out of actuators. They may be operated mechanically or electrically and may use rotary or linear (spool) movement.

Two-port and four-port rotary selectors

    Linear or spool selectors

    A spool valve uses linear movement to connect or block ports. The source describes mechanical actuation by a rod or cable, and solenoid operation where electrical power moves the spool. Springs centralise the spool when the electrical input is removed. In a solenoid-operated arrangement, pressure may be ported to the ends of the spool to assist movement.

    Hydraulic lock

    When a selector is positioned so that fluid can neither enter nor leave an actuator, the fluid is trapped. The ram cannot move in either direction and the actuator is hydraulically locked. This is useful for holding a component in a selected position.

    Remember: hydraulic lock is produced by trapping fluid. It is not the same thing as a mechanical uplock or downlock on landing gear.

    Four-port selector — trace the two paths

    For a double-acting jack, a selector must do two things at the same time: supply pressure to one side of the piston and provide a return route for fluid displaced from the opposite side. To reverse the actuator, the selector swaps those connections. If the return route is blocked, the actuator may stall or the circuit may experience an abnormal pressure rise.

    Extend

    Pressure → cap end; rod end → return. The piston and ram move outward.

    Retract

    Pressure → rod end; cap end → return. The piston and ram move inward.

    Fault-finding example: If the selector is commanded to extend but the actuator does not move, possible causes include no pressure supply, a selector that has not shifted, a blocked return path, a mechanical obstruction, internal leakage or an actuator fault. The schematic and approved troubleshooting procedure are needed to isolate the cause.

    7. Non-return valves and hand pumps

    Non-return valves (NRVs)

    An NRV prevents reverse flow and helps retain pressure downstream. In the source example, a spring holds a ball against its seat. Forward flow pushes the ball off its seat; when flow stops or reverses, the spring returns the ball to the seat. The valve body is marked with an arrow showing the permitted flow direction.

    Hand pumps

    Hand pumps can raise brake pressure without starting engines, operate cargo doors and provide emergency hydraulic power in flight where fitted. The source states that their supply is taken from the bottom of the reservoir. Two types are described:

      Practical example: If a ground task requires hydraulic pressure to open a cargo door, a hand pump may provide that pressure without running the aircraft engines, provided the aircraft procedure permits it.

      Why the hand pump includes check valves

      The inlet NRV ensures that the pump draws fluid from the reservoir rather than pulling it backwards from the pressure line. The outlet NRV ensures that the pressure produced on the delivery stroke is sent towards the service and is not lost back through the pump. In a double-acting design, transfer NRVs allow fluid to move between chambers so useful delivery occurs on both handle strokes.

      Worked example — hand-pump delivery: If a hand pump displaces 12 cm³ on each effective stroke and delivers on both strokes, 10 complete up-and-down cycles ideally deliver 12×20 = 240 cm³. Actual delivery will be lower if there is leakage, incomplete stroke or fluid compression from entrained air.

      8. Active hydraulic systems and pressure generation

      A passive system generates pressure only when an external force moves an input piston, as in a basic hand-operated brake system. An active system uses a mechanically driven pump to maintain a source of hydraulic pressure for connected services.

      Category in older training material notesPressure rangeTypical pump family described
      Low pressureUp to 2,000 psiSpur gear and vane pumps
      High pressure2,000–4,500 psiPiston pumps

      The chapter distinguishes constant-volume (constant-displacement) pumps from constant-pressure (variable-volume/variable-displacement) pumps.

      Positive-displacement pump principle

      The pump does not create pressure in isolation. It displaces a volume of fluid into a circuit. When the circuit resists that flow, pressure rises until the fluid can move a load, pass through a regulating device or flow through a relief path. A positive-displacement pump therefore needs protection against a blocked outlet: without a relief or regulation path, pressure can rise to a damaging level.

      9. Open-centred hydraulic systems

      Early EDP systems would pump whenever the engine was running. Without a means of off-loading the pump, pressure and temperature could rise unnecessarily, engine power would be used, and pump wear would increase. The open-centred arrangement was developed to reduce this continuous load when services were not selected.

      Open-centred selector arrangement

      In the idle condition, fluid circulates through the centre passage of the open-centred selectors and returns, keeping system pressure low. Selecting a service closes the bypass path and directs pump output into that actuator. The source describes this as a low-pressure arrangement used on older light aircraft for flaps, landing gear and air brakes. In the described series arrangement, only one actuator can be operated at a time.

      Open-centred system with an off-loading/unloading valve

      The later arrangement uses a system bypass valve. When no service is selected, the pump is off-loaded. When a pilot makes a selection, the bypass valve closes and pump flow is directed to the selected service. The example notes that the services are in parallel, allowing more than one service to operate simultaneously. A full-flow relief valve protects the system if the bypass valve fails closed.

      FeatureOpen-centred selectorsOff-loading valve version
      Idle conditionFluid circulates through selector centre passages.Bypass/off-loading valve returns pump flow.
      Service arrangementSeries; source describes one service at a time.Parallel; source describes simultaneous service operation.
      ProtectionRelief valve protects against selector failing to return open.FFRV protects if bypass valve fails closed.

      Trace the flow — two open-centred layouts

      Open-centred selectorsOff-loading valve arrangementSelector ASelector BBypassServiceIdle flow passes through centrePump flow bypassed when idle

      10. Pressure relief valves and closed-centred systems

      Pressure relief valve (PRV)

      A PRV protects a hydraulic system from overpressure. In the ball-type design described in the source, a spring holds a ball against its seat. When pressure reaches the cracking value, the ball lifts and allows fluid to return. If it can relieve the entire pump output, it is called a full-flow relief valve (FFRV).

      As pressure falls, the spring reseats the ball. The pressure at which this occurs is the reseating pressure. The source gives the order from highest to lowest as:

      Full-flow pressure > Cracking pressure > Reseating pressure > Normal pressure

      When a PRV operates, it may hold the system at a higher pressure and raise fluid temperature. The source identifies an increased supply-gauge reading together with increased temperature as indications that normal pressure regulation may not be functioning correctly.

      Closed-centred systems

      Large transport aircraft require a constant head of pressure so multiple services can respond rapidly, including power-assisted flying controls. Closed-centred systems can operate multiple services at the same time and provide higher output force through higher working pressure. The source gives a typical standard pressure of about 3,000 psi, with systems ranging from about 1,000 to 4,500 psi.

      Higher pressure allows a given force to be produced by smaller actuators, with less fluid volume and smaller-diameter pipes. This can reduce installation difficulty and system mass. Return lines are larger-bore than pressure supply lines to reduce resistance and back pressure.

      11. Fixed-volume (constant-displacement) piston EDP

      In a closed-centred system, an older arrangement uses a constant-volume high-pressure pump with a pressure regulator or automatic cut-out valve (ACOV). The pump moves a constant volume for every revolution regardless of system pressure, so a regulating device is required to off-load it when working pressure is reached.

      The fixed-displacement pump uses reciprocating pistons in a rotating cylinder block. The angled relationship between the pump body and drive shaft causes the pistons to reciprocate. The source describes seven- or nine-piston arrangements, a universal joint, piston rods and shoes, and a valve plate (sometimes called a kidney plate) with two kidney-shaped ports.

      How the pumping cycle works

      1. As the cylinder block rotates, pistons on the inlet side move to draw fluid into their bores.
      2. At bottom dead centre, the piston bore passes across the bridge in the valve plate.
      3. On the pressure side, pistons move to displace fluid through the outlet port.
      4. Pressure rises as the displaced fluid enters the restrictive pressure circuit.

      The pump requires cooling and lubrication. A controlled bleed of fluid circulates around the moving parts and exits through the case drain. The source describes this fluid being filtered or returned upstream of a low-pressure return filter. The quill drive is designed as a weak point so a seized pump is less likely to damage the engine gearbox.

      Why a quill drive is deliberately a weak link

      The quill drive is a mechanical protection feature. If the pump seizes, the drive is intended to fail before the seizure transmits damaging torque into the engine accessory gearbox. This is a controlled mechanical failure designed to protect a more expensive and safety-critical drive system. A failed quill drive means that the associated EDP no longer provides hydraulic power; system redundancy and alternate pumps become important.

      Reading the pump cycle

      Think of the cylinder block as rotating past two kidney-shaped ports. On the inlet side, increasing piston chamber volume draws fluid in. After passing the bridge, chamber volume decreases on the pressure side and fluid is expelled. The valve plate separates the inlet and delivery regions so the two sides do not communicate directly.

      Further reading: UK AP3456 aircraft hydraulic systems reference explains swash-plate axial-piston pump operation.
      Worked example — pump delivery: A fixed-displacement pump has a theoretical displacement of 18 cm³/rev and rotates at 4,500 rpm. Theoretical flow = 18×4,500 = 81,000 cm³/min = 81 L/min. Actual flow is lower due to volumetric losses and leakage.

      12. Filtration and micronic pressure filters

      Pump wear can introduce particles into the hydraulic fluid, so filters are commonly installed downstream of the pump. Some systems also use a low-pressure filter in the return line immediately before the reservoir; some use both high- and low-pressure filters.

      The chapter describes a full-flow micronic pressure filter (FFMPF): all pump output passes through the element before reaching downstream components. The notes emphasise that particles around 25 microns and above must be removed without restricting flow.

      Filter warning and bypass operation

      • As debris accumulates, the filter element becomes more restrictive.
      • The pressure upstream rises while downstream pressure falls.
      • Pressure switches on each side detect the differential and illuminate a filter warning.
      • The warning indicates clogging, not necessarily complete blockage. Follow the aircraft flight manual/approved procedure.
      • If differential pressure reaches the bypass setting, a bypass relief valve opens so unfiltered fluid can continue to flow. Some installations show a red telltale button (“filter popping”).
      Important: a filter bypass protects continued fluid supply, but it also allows contamination downstream. A warning must not be dismissed as harmless.

      Micron size in context

      A micron (µm) is one millionth of a metre. Standard training material uses 25 µm as a reference particle size for the pressure-filter discussion and compares it with a human hair of roughly 100 µm diameter. A particle much smaller than a hair can still damage close-fitting hydraulic components or score a precision surface.

      Worked example — filter differential: If pressure upstream of a filter is 3,000 psi and downstream pressure is 2,940 psi, the differential is 3,000 − 2,940 = 60 psi. The warning threshold is aircraft-specific; do not assume that this example is a service limit.

      13. Hydraulic accumulators

      An accumulator stores hydraulic energy by using a compressible gas separated from the hydraulic fluid. It can smooth pressure fluctuations, supply short-duration emergency flow and reduce rapid cycling of a pressure regulator/ACOV. The source describes early designs where mixing of air and fluid created serious risks; modern designs use a separator piston, bladder or diaphragm and an inert gas, preferably nitrogen.

      Operating principle

      1. With the system slack, a gas pre-charge is present in the accumulator.
      2. When system pressure exceeds the gas pre-charge, hydraulic fluid enters and compresses the gas.
      3. At system working pressure, the gas and fluid pressures are equal and the accumulator is charged.
      4. When demand causes system pressure to fall, the compressed gas pushes stored fluid back into the system.

      Pre-charge and system failure

      The source states that the nominal pre-charge is about one third of working pressure, but the correct value is aircraft-specific and must come from the maintenance data. If the pump fails, an upstream NRV closes to prevent stored pressure escaping back through the pump. The accumulator can then provide a limited emergency supply. The source gives the example of approximately six full manual brake reversals in the wheel-brake system.

      If pre-charge is too high, the accumulator accepts less fluid. Pressure may remain available while the stored fluid volume is inadequate, reducing the number of available service operations. Incorrect pre-charge can also affect reservoir level, fluid temperature and ACOV cycling.

      Worked example 5 — nominal pre-charge: If a system has a working pressure of 3,000 psi and the design uses a nominal one-third pre-charge, the illustrative pre-charge is 3,000 ÷ 3 = 1,000 psi. This is a learning calculation only; never use it as a servicing value.

      Accumulator types and what the separator achieves

      The gas and hydraulic fluid must remain separated. A piston-type accumulator uses a movable piston with seals; a bladder-type uses a flexible bladder; and a diaphragm-type uses a flexible membrane. Each allows gas compression while preventing direct mixing of gas and fluid. The source emphasises inert nitrogen for the gas charge.

      Nitrogen gasHydraulic fluidSeparator pistonFluid portGas charging valveTo hydraulic pressure line

      Accumulator behaviour under demand

      When a service draws fluid, system pressure falls and the compressed gas expands, pushing fluid back into the pressure line. The accumulator does not create new energy; it returns energy stored during charging. Once its useful stored volume is exhausted, it cannot maintain the system indefinitely.

      Worked example — useful fluid volume: Suppose an accumulator is charged and its usable fluid volume between the specified high and low pressure limits is 0.75 L. If one brake application consumes an estimated 0.12 L, the ideal number of applications is 0.75 ÷ 0.12 = 6.25. In practice, usable applications depend on pressure limits, system design, leakage and the required brake performance.

      14. Constant-pressure (variable-volume) pump

      A variable-displacement or variable-volume piston pump incorporates pressure regulation into the pump. In the description, piston stroke is controlled by a swash plate. The angle of the swash plate determines the stroke and therefore the pump’s displacement.

      A spring tends to move the swash plate towards maximum deflection. System pressure acts on a control piston to move it towards neutral. When demand increases and pressure falls, the spring increases swash-plate angle and pump output. When demand is satisfied and pressure rises, the control piston reduces the angle and the pump idles at minimum displacement.

      Depressurisation and isolation during engine start

      The source describes a depressurisation/isolation arrangement used to off-load the pump during engine start. It includes a reservoir shut-off valve, blocking valve, depressurising solenoid valve and compensating valve. The pilot selects depressurise before starting; after a successful start and correct engine rpm, the control is returned to normal. In normal mode the solenoid is de-energised and spring-returned, so hydraulic power remains available if electrical power is lost.

      Do not confuse: fixed-displacement pumps deliver a fixed volume per revolution and need a regulator/off-loading device; variable-displacement pumps alter their output by changing piston stroke.

      Displacement control — what the swash plate changes

      At a larger swash-plate angle, pistons have a longer stroke and the pump displaces more fluid per revolution. As the swash plate moves towards neutral, piston stroke and displacement reduce. The engine may continue turning the pump while the pump produces only the flow required to maintain pressure and compensate for leakage.

      High demand

      System pressure falls → control mechanism increases swash-plate angle → piston stroke increases → pump delivery rises.

      Low demand

      System pressure recovers → control piston reduces swash-plate angle → piston stroke decreases → pump delivery falls.

      Worked example — displacement change: If a pump’s maximum displacement is 20 cm³/rev but the regulator reduces it to 25% of maximum, actual displacement is 20×0.25 = 5 cm³/rev. At 4,000 rpm, theoretical flow is 5×4,000 = 20,000 cm³/min = 20 L/min.

      15. Hydraulic fluids, temperature and heat exchangers

      The source lists the desired properties of aircraft hydraulic fluid: low viscosity, heat resistance, chemical stability, non-flammability, resistance to foaming, good lubrication and corrosion resistance. Low viscosity helps fluid move through pipes and components with less internal friction, while stability across a wide temperature range helps preserve performance.

      Air and foaming

      Air entering the pump inlet can cause cavitation and interrupt pressure output. Air in the system can also compress and expand as pressure changes, potentially causing unwanted actuator movement. Foaming in the reservoir can allow air bubbles to be drawn into the pump; anti-foaming additives help reduce this risk.

      Fluid families in the source notes

      FamilySource descriptionCompatibility point
      Vegetable-basedCastor oil and alcohol; almost colourless; limited temperature tolerance and flammable.For use only with compatible pure-rubber seals and hoses.
      Mineral-basedPetroleum/kerosene product; red dye in the source description; used in military and light aircraft and some shock absorbers.Requires compatible synthetic-rubber seals and hoses.
      Synthetic phosphate-esterSkydrol is a trade name; the source describes purple Type IV fluids and Type V.Requires compatible materials such as butyl rubber, ethylene propylene or PTFE/Teflon.
      Servicing safety: never select a fluid by colour alone. Use the aircraft maintenance documentation and specified product. Hydraulic fluids and their additives can be hazardous; prevent skin/eye contact and follow the safety data sheet.

      Fluid temperature

      Cold fluid becomes more viscous and can make services sluggish. Excessive heat can cause chemical breakdown. The source describes temperature sensing at the reservoir and heat exchangers in the return or suction line.

      Heat exchangers

      Cooling may be provided by ram air or by a heat exchanger immersed in unusable fuel in a fuel tank. The latter transfers unwanted hydraulic heat to the fuel, helping prevent fuel waxing/freezing while cooling the hydraulic fluid. A bypass valve allows fluid to bypass a blocked heat exchanger, but fluid temperature will rise. A leaking fuel/hydraulic heat exchanger can contaminate the hydraulic system with fuel and affect viscosity, stability, flammability, lubrication and seals.

      Viscosity: the practical trade-off

      Viscosity is a fluid’s resistance to flow. If viscosity is too high, cold fluid creates greater resistance in pipes and filters, increases pump inlet difficulty and can slow actuator response. If viscosity is too low, internal leakage can increase and lubricating films may become inadequate. The approved fluid grade is selected to operate within the aircraft’s specified temperature range.

      Why mixing fluids is not a minor mistake

      Different fluid families can use different seal materials and have different chemical properties. An incompatible fluid can cause seals to swell, soften, shrink or deteriorate. The resulting leakage may be internal, external or both. Contamination can also alter viscosity and promote overheating. The correct response is determined by the approved maintenance data; do not attempt to correct a suspected mix simply by topping up with the expected fluid.

      16. Seals, backing rings and leakage

      Seal sections and direction

      • Round and square section seals can seal hydraulically in both directions.
      • U- and V-section seals seal in one direction when pressure acts into the section. A double-acting actuator therefore needs seals arranged to seal in both directions.
      • Backing rings support dynamic seals and help prevent them rolling or extruding as the piston moves.
      • Wiper/scraper rings remove dirt and grit from the ram as it retracts. They protect the dynamic seal but are not themselves the primary hydraulic seal.

      Internal and external leakage

      Leakage typeWhat happensPossible consequence
      InternalFluid passes from the pressure side of a piston to the return side, often due to a damaged seal or worn bore.Pressure loss, loss of hydraulic lock and increased temperature as regulation cycles more often.
      ExternalFluid escapes past a static seal or actuator ram seal.Fluid loss, higher temperature of remaining fluid, fire risk depending on fluid, and possible electrical contamination.

      The source distinguishes a static leak, which may occur when the system is slack, from a dynamic leak that occurs under pressure. A dynamic leak can produce a free-running stream or spray and is not treated as an acceptable leak rate in the source discussion.

      Maintenance boundary: never touch, search for or tighten a suspected high-pressure leak while the system is pressurised. Follow the approved aircraft maintenance procedure and depressurisation precautions.

      Seal failure mechanisms

      Extrusion

      Pressure forces seal material into a clearance gap. A backing ring helps support the seal where required by design.

      Rolling or twisting

      Friction on a moving ram can drag a seal out of its intended position. Backing/support arrangements reduce this risk.

      Abrasive damage

      Dust or grit on a ram can score the seal during retraction. Wiper rings remove contamination before it reaches the main seal.

      Material incompatibility

      Incorrect fluid can attack seal compounds and lead to leakage or loss of sealing force.

      Worked example — identifying a leak: A jack slowly creeps despite the selector being in hydraulic lock, with no visible external fluid loss. One possible explanation is internal leakage past the piston seal. This is not a definitive diagnosis: valve leakage, load-induced movement and other system faults must also be considered.

      17. System reservoirs and fluid contamination

      The reservoir must store enough fluid for normal service demand and provide for small leaks, ram displacement, thermal expansion, air removal and emergency reserve. It must also ensure that only fluid reaches the pump inlet, provide a way to check level and allow replenishment.

      Pressurised reservoir features

        The source distinguishes the slack level from the working level. The slack level is checked with the aircraft configured as specified in the flight manual (for example, landing gear down and locked, flaps retracted and accumulators correctly dissipated/pre-charged). The working level changes as services are operated and accumulators charge.

        Contamination

        If the wrong fluid is added, the source instructs that the system must not be operated and the supply cock must not be opened. Incompatible fluid can damage seals, cause internal/external leakage, increase temperature, alter viscosity and contribute to cavitation. Correct fluid identification and approved servicing procedures are essential.

        Why the standpipe protects an emergency reserve

        The normal EDP supply is taken from the standpipe/stack pipe, whose inlet is above the reservoir bottom. If the main system suffers a major fluid loss, the pump pick-up can uncover before all the fluid is lost. Fluid below the standpipe remains as a reserve for the emergency supply or hand pump, as described in the source. Baffles and fins reduce swirling so the pump inlet is less likely to ingest air.

        Further reading: FAA AC 65-15A contains reservoir construction diagrams, including filler neck, sight gauge, baffles, standpipe and pump connections.

        Reservoir pressurisation and cavitation

        At altitude, ambient pressure decreases. If the reservoir airspace is only at ambient pressure, the pump inlet pressure can become too low. Pressurising the reservoir maintains a positive pressure at the pump inlet and helps prevent cavitation. In cavitation, local pressure falls sufficiently for vapour cavities to form; when they collapse, they can cause noise, vibration and damage. Foaming and dissolved-gas release are related but not identical phenomena.

        Worked example — reservoir level interpretation: A reservoir level is not necessarily expected to remain at one fixed mark throughout operation. Actuator ram displacement, accumulator charging and fluid temperature all affect the level. Check the aircraft’s specified configuration and hot/cold markings before deciding that a level is abnormal.

        18. Hydraulic services, redundancy and priority

        The chapter lists transport-aircraft hydraulic services including power flying controls, artificial feel (Q-feel), trailing- and leading-edge flaps, lift dumpers, spoilers/speed brakes, landing gear, and wheel brakes.

        The source’s twin-engine aircraft schematic uses three colour-identified systems: blue, green and yellow. Multiple systems may supply a service to provide redundancy. The design philosophy is that a single failure should not cause loss of the aircraft’s essential services.

        Priority services

        The source identifies primary flying controls and wheel brakes as priority services. A pressure-maintaining valve (PMV), also called a priority valve, protects their supply by isolating secondary services if system pressure falls below a predetermined value. When pressure is sufficient, the valve opens to supply secondary services; when pressure falls, it closes so available pressure is retained for primary services.

        Operational example: If a hydraulic system is deteriorating, a priority valve can shed a non-essential demand before pressure is lost from the primary flying controls and wheel brakes.

        Redundancy: independent systems and shared services

        Multiple hydraulic systems can be routed to separate actuators or separate sections of a service. A flight-control surface may have more than one hydraulic power source so that loss of one source does not automatically remove all control capability. The architecture varies by aircraft: some systems share a service through independent actuators, while others use tandem actuators or power-transfer devices. Never assume that system colours or the number of pumps is identical across aircraft types.

        19. Pressure reducing and thermal relief valves

        Pressure reducing valve

        A pressure reducing valve supplies a subsystem that requires a lower pressure than the main system, such as wheel brakes on some aircraft. As subsystem pressure rises, the valve moves against its spring and restricts inlet flow. If pressure exceeds the required value, the valve allows fluid to return, balancing the subsystem pressure.

        Thermal relief valve (TRV)

        A TRV protects fluid trapped between components by hydraulic lock. If the temperature of the trapped fluid rises, its pressure increases. At the set value the valve opens briefly to allow a small amount of fluid into the return line, then reseats. The source notes that the TRV is physically smaller than a PRV but operates at a higher pressure setting.

        20. Hydraulic motors, PTUs and ram air turbines

        Hydraulic motors

        A hydraulic motor converts fluid pressure and flow into rotary movement. The chapter describes cranked and swash-plate types. Fluid pressure acting on pistons creates force; the angled geometry converts the linear piston movement into rotation. Pressure determines available torque, while flow rate determines rotational speed. Flow control is therefore used where stable motor speed is required.

        Power transfer unit (PTU)

        A PTU transfers hydraulic power between two independent systems without necessarily mixing their fluids. The source describes earlier arrangements with a hydraulic motor in one system driving a pump in another, and modern bidirectional arrangements where either side can act as motor or pump as required.

        Ram air turbine (RAT)

        The RAT provides limited hydraulic power to primary services if normal hydraulic power generation fails. In the source description, a variable-pitch propeller drives a small hydraulic pump through a gearbox. The RAT is normally stowed and held in place by system pressure. When system pressure falls below a set value and the aircraft is below a specified airspeed, it deploys into the airflow and begins windmilling.

        The RAT first recharges its own accumulator and then supplies the main system. Priority valves ensure that primary services receive available flow. If deployed in flight, it may remain deployed through landing, although its effectiveness decreases as airspeed reduces.

        PTU — transfer power, not necessarily fluid

        In a PTU, the pressurised fluid in one system drives a hydraulic motor. The motor’s rotating shaft drives a pump connected to the second system. The two fluid circuits remain separate; the mechanical connection transfers energy between them. This is particularly useful when one system has lost its normal pump source but the other system still has pressure available.

        RAT — airflow becomes emergency hydraulic power

        The RAT is an emergency source, not a normal substitute for the aircraft’s engine-driven pumps. Its available output depends on airflow and the turbine/pump design. As airspeed falls during approach and landing, its effectiveness decreases. The system therefore prioritises essential loads and may use an accumulator to bridge the deployment and pressure-build-up interval.

        Further reading: FAA Aviation Maintenance Technician Handbook, Airframe Volume 2 includes a large commercial-aircraft hydraulic architecture diagram identifying the RAT and system services.
        Worked example — PTU concept: If system A has adequate pressure but system B’s normal pump has failed, a PTU can use A’s hydraulic energy to drive a pump that pressurises B. This does not mean fluid from A is transferred into B; the two fluid circuits can remain isolated.

        21. Flow control valves and restrictors

        Flow control valve

        A flow control valve is fitted upstream of a component such as a hydraulic motor to maintain a required flow rate. The source gives an example of a motor requiring 5 litres per minute while supply flow varies between 5 and 10 litres per minute. As flow increases, force on the valve head moves it against a spring and reduces the opening. A damping arrangement helps prevent rapid valve oscillation.

        Two-way and one-way restrictors

        TypeFunctionTypical application in source
        Two-way (choke)Restricts flow in both directions.Speed control on some light-aircraft retractable landing gear.
        One-wayAllows relatively free flow one way and restricts the return flow.Controls landing-gear extension or flap retraction rate.

        Restrictor location matters because gravity and aerodynamic loads can accelerate a service. For landing-gear extension, the source places a one-way restrictor in the up line to control fluid leaving the actuator. This creates back pressure and prevents the gear falling too rapidly. For flap retraction, the restrictor controls fluid leaving the down side so aerodynamic loads cannot force the flaps up faster than fluid can enter the actuator.

        Worked example 6 — actuator speed: If an actuator displaces 1.8 litres in 12 seconds, average flow = 1.8 ÷ 12 = 0.15 L/s. Convert to litres per minute: 0.15 × 60 = 9 L/min.

        Throttling valve

        A throttling valve can replace a restrictor. The source describes a spring-loaded core and a shaped needle that varies the flow opening. Because the core is coned at both ends, the valve can control inflow and outflow, including flap-system operation.

        Why restrictor placement changes the result

        A restrictor can control actuator speed by limiting the fluid leaving a chamber. On a landing-gear extension circuit, the gear’s weight and gravity can assist movement. Restricting the exhaust flow creates back pressure that damps the movement. If the restriction were instead placed so that the actuator could not receive enough make-up fluid, a low-pressure condition or cavitation could occur on the expanding side of the cylinder.

        For flap retraction, aerodynamic loads can help drive the flaps towards the retracted position. Controlling the fluid leaving the actuator chamber prevents the air load from forcing the flap system to move faster than the hydraulic circuit can safely accommodate.

        Worked example — time from flow: A cylinder with an effective area of 5 cm² must travel 20 cm. Required volume = 5×20 = 100 cm³. If controlled flow is 500 cm³/min, ideal travel time = 100÷500 min = 0.2 min = 12 seconds.

        22. Hydraulic fuses, sequence valves and shuttle valves

        Hydraulic fuse

        Hydraulic fuse — simplified operating concept

        Pressure supplyHydraulic fuseServiceFlow-sensing pistonAbnormally high downstream flow causes the fuse to close the branch

        Sequence valves

        Sequence valves ensure that one operation is completed before another begins. The source uses landing-gear extension as the example: doors must open before the gear unlocks and extends. Three types are described:

          During gear extension, the door actuator first opens the door. A microswitch then triggers the electrical sequence valve to release the uplock. When the door reaches its travel limit, pressure builds to move the hydraulic sequence valve and supply the gear actuator. Mechanical sequencing controls the return flow so the door does not close onto the moving gear. Retraction follows the reverse sequence.

          Shuttle valve

          A shuttle valve allows a service to receive pressure from either of two independent supplies. Under normal conditions, system pressure holds the shuttle piston so the normal supply is connected. When the pilot selects an emergency/alternate supply, its pressure moves the shuttle across, blocks the normal supply port and connects the alternate source. The source gives emergency flap/undercarriage operation and wheel brakes as examples.

          Why sequencing is a safety function

          Landing-gear doors and gear legs occupy overlapping space. If the gear starts moving before the doors have opened sufficiently, the mechanism could foul or damage the doors. A sequence valve enforces the required order rather than relying solely on the pilot to time separate actions. Mechanical, hydraulic and electrical sequencing can be combined so that the system responds to actual component position or pressure build-up.

          Worked example — fault logic: If the gear doors open but the gear does not unlock, the fault may lie in the electrical sequence circuit, the uplock actuator, the hydraulic sequence valve or its supply. If the doors never reach the open position, the gear sequence should remain inhibited. The correct troubleshooting path follows the aircraft circuit and maintenance manual.

          23. Pressure indication and pressure relays

          Direct-reading gauge

          Older aircraft may use a Bourdon-tube gauge. System fluid fills the tube. As pressure rises, the tube tends to straighten; a linkage and gearing convert this movement into needle movement on a calibrated dial.

          Pressure relay

          A pressure relay is fitted in the sensing line between the hydraulic system and a direct-reading gauge. It transmits system pressure to the gauge through a piston arrangement. If the sensing line leaks, the relay piston moves to seal the outlet to the gauge. The indication is lost, but continued loss of system fluid is limited.

          Interpretation: a lost gauge indication does not automatically mean the hydraulic system itself has lost pressure. A pressure relay may isolate a leaking gauge line while preserving the main system.

          What the gauge can — and cannot — tell you

          A pressure gauge reports pressure at its sensing point, not the health of every downstream component. A normal system pressure indication does not prove that an individual actuator is moving correctly; a blocked selector, mechanical jam or internal leak can still affect a service. Conversely, a failed gauge line isolated by a pressure relay can remove the indication while limiting fluid loss from the main system.

          24. Chapter summary and key takeaways

          • Hydraulics use a virtually incompressible fluid to transmit power from a pump or input force to remote actuators.
          • Pascal’s law explains equal pressure transmission through an enclosed fluid. Force depends on pressure multiplied by effective piston area.
          • Force multiplication uses a small input piston and a larger output piston; output force increases while output travel decreases.
          • Single-acting actuators are hydraulically powered in one direction; double-acting actuators are powered in both directions. An unbalanced actuator produces unequal extension/retraction forces; a balanced actuator has equal ram areas.
          • Selector valves direct flow. Trapping fluid in an actuator creates hydraulic lock. NRVs prevent reverse flow.
          • Passive systems require an external input to generate pressure; active systems use pumps.
          • Open-centred systems off-load pump output when idle. Closed-centred systems maintain a pressure supply for multiple services.
          • Fixed-displacement pumps deliver a fixed volume per revolution and require regulation. Variable-displacement pumps alter piston stroke to match demand.
          • Filters protect components but can clog; differential-pressure warnings and bypass valves are important system features.
          • Accumulators store energy using compressed gas separated from fluid. They smooth pressure and provide limited emergency supply.
          • Fluid compatibility, temperature, cleanliness, seals and reservoir condition are essential to reliable operation.
          • Priority valves protect primary services; PTUs transfer hydraulic power; RATs provide emergency power; restrictors, fuses, sequence valves and shuttle valves control system behaviour.
          Big-picture mental model: reservoir stores fluid → pump creates flow → resistance produces pressure → filters and valves condition/direct flow → actuator or motor performs work → return flow goes back to the reservoir. Accumulators, priority devices and alternate power sources help maintain essential operation when faults occur.

          25. Knowledge check

          1. According to Pascal’s law, pressure applied to an enclosed fluid is:

          Correct: A — Pascal’s law states that pressure is transmitted equally in an enclosed fluid.

          2. A 120 lbf force acts on a piston area of 6 in². What pressure is produced?

          Correct: B — 120 ÷ 6 = 20 psi.

          3. In an ideal hydraulic press, increasing output piston area while keeping pressure constant will:

          Correct: B — force equals pressure multiplied by area.

          4. Which actuator produces a greater force on extension than retraction at equal pressure?

          Correct: C — the ram reduces effective piston area on the ram side.

          5. A hydraulic lock is created when:

          Correct: B — trapped fluid prevents ram movement.

          6. The main purpose of an NRV is to:

          Correct: C — an NRV permits flow in one direction and prevents backflow.

          7. Which statement best describes an open-centred selector system at idle?

          Correct: B — the open centre allows circulation and off-loads the pump.

          8. What is the main distinction between a fixed- and variable-displacement pump?

          Correct: B — variable-displacement pumps adjust piston stroke, commonly through swash-plate angle.

          9. An accumulator stores hydraulic energy primarily by:

          Correct: A — the gas is compressible and stores energy as fluid enters.

          10. A priority valve closes when system pressure falls in order to:

          Correct: B — primary flying controls and wheel brakes receive priority in the source chapter.

          11. The main function of a hydraulic fuse is to:

          Correct: B — it isolates the leaking branch to protect the rest of the system.
          Correct: A — the shuttle moves to select normal or alternate/emergency supply.

          Further study

            Supplementary references and illustrations

            Internet images and original AeroLearn SVG diagrams are explanatory aids. They are not reproductions of the figures and should not be used to identify the exact configuration of a particular aircraft. Where a diagram is type-specific, the aircraft maintenance/flight documentation takes precedence.

            Training note: These are educational study notes, not aircraft maintenance instructions. Aircraft-specific pressure values, servicing, fluid selection, inspection limits, emergency procedures and component operation must always be checked against the applicable AFM/FCOM, AMM and approved maintenance data.