Introduction
An aircraft electrical system is not simply a collection of wires, batteries and switches. It is an engineered network that must deliver the correct voltage and current to essential equipment, tolerate demanding environmental conditions, protect against faults and allow the flight crew to recognise abnormal operation.
Before studying generators, alternators, batteries, busbars and electronic control units, a student must understand the behaviour of electricity itself. This chapter develops that foundation. We begin with the structure of matter and the movement of electric charge, then build toward circuit analysis and the devices used to control and protect aircraft wiring.
Electrical theory is cumulative. Understanding the difference between voltage and current makes Ohm's law meaningful. Understanding resistance makes voltage drop and heating predictable. Understanding series and parallel circuits makes aircraft distribution diagrams easier to interpret. These principles will be used repeatedly in Chapters 17–21.
Learning objectives
- Describe the atomic basis of electricity and distinguish conductors, insulators and semiconductors.
- Define charge, electromotive force, potential difference, current, resistance, power and energy.
- Apply Ohm's law and electrical power equations to practical calculations.
- Analyse simple series, parallel and combined circuits.
- Apply Kirchhoff's current and voltage laws to circuit networks.
- Explain the operation and applications of switches, relays, contactors, fuses and circuit breakers.
- Describe capacitor construction, charging, discharging and basic aircraft applications.
- Relate circuit theory to aircraft wiring, voltage drop, overloads and electrical faults.
Visual guide — electrical systems in the aircraft environment
These photographs connect the theory to real aircraft installations. They are illustrative references, not approved instructions for component identification, testing or replacement.
1. Matter and electric charge
1.1 Atomic structure
All ordinary matter is made from atoms. An atom contains a small, dense nucleus surrounded by electrons. The nucleus contains positively charged protons and electrically neutral neutrons. Electrons carry negative charge and occupy regions around the nucleus.
An atom is electrically neutral when it contains equal numbers of protons and electrons. If an atom loses one or more electrons, it becomes a positively charged ion. If it gains electrons, it becomes a negatively charged ion. In metallic conductors, some outer electrons are relatively free to move through the material. Their movement provides the basis of electrical conduction.
Positive charge; located in the nucleus.
No net electric charge; located in the nucleus.
Negative charge; mobile electrons in conductors carry current.
An atom or molecule with a net electric charge due to electron loss or gain.
1.2 Electric charge
Electric charge is a fundamental property of matter. The SI unit is the coulomb (C). The magnitude of the charge carried by one electron is approximately \(1.602\\times10^{-19}\\) coulomb. A coulomb therefore represents a very large number of elementary charges.
Like charges repel and unlike charges attract. This interaction is the basis of electrostatic effects. Charge can be transferred between objects by contact, friction or induction, but in a closed system total electric charge is conserved.
1.3 Conductors, insulators and semiconductors
Materials differ in how easily charge carriers can move through them. The distinction is not absolute: temperature, impurities, moisture, mechanical damage and applied voltage can alter electrical behaviour.
| Material class | Electrical behaviour | Examples and relevance |
|---|---|---|
| Conductors | Contain mobile charge carriers and have relatively low resistance. | Copper and aluminium conductors used in aircraft wiring; silver is an excellent conductor but is not normally selected for general aircraft wiring because of cost and other practical factors. |
| Insulators | Strongly resist the movement of charge under normal operating conditions. | Wire insulation, ceramic supports, glass and many polymers. Insulation prevents unintended current paths. |
| Semiconductors | Conductivity lies between that of conductors and insulators and can be controlled by doping, temperature, light or electric fields. | Silicon and germanium form the basis of diodes, transistors and integrated circuits. These are developed further in Chapter 21. |
1.4 Conventional current and electron flow
2. Electromotive force, potential difference and current
2.1 Electromotive force (EMF)
One volt corresponds to one joule of energy transferred per coulomb of charge. A source's EMF describes the energy it can supply per unit charge under the defined conditions. When current flows, internal resistance can cause the terminal voltage to be lower than the EMF.
2.2 Potential difference (voltage)
Potential difference is the energy transferred per unit charge between two points in a circuit. A component such as a lamp, heater or motor receives electrical energy and converts it into light, heat or mechanical work. The voltage across the component represents the energy transferred per coulomb as charge passes through it.
Voltage is always measured between two points. A voltmeter is therefore connected in parallel with the component or points being measured. An ideal voltmeter has very high resistance so that it draws negligible current and does not significantly disturb the circuit.
2.3 Electric current
Current is the rate of flow of electric charge. Its SI unit is the ampere (A). A current of one ampere means one coulomb of charge passes a point each second.
Current requires a complete conducting path and a driving potential difference. Opening a switch breaks the path and, in a simple circuit, stops the current. A current can be dangerous because it produces heating and can interfere with biological electrical activity. The actual hazard depends on current magnitude, path through the body, duration, frequency and contact conditions.
2.4 Measuring voltage and current
| Instrument | Connection | Desired input characteristic | Purpose |
|---|---|---|---|
| Voltmeter | In parallel | Very high resistance | Measures potential difference between two points. |
| Ammeter | In series | Very low resistance | Measures current flowing in a branch. |
| Ohmmeter | Across an isolated component/circuit | Uses an internal test source | Measures resistance; circuit must be de-energised and appropriately isolated. |
3. Resistance, resistivity and conductors
3.1 Meaning of resistance
Resistance is the opposition a material or component offers to current flow. It is measured in ohms (Ω). In a simple resistive component, increasing the applied voltage increases current; increasing resistance reduces current for the same voltage.
At microscopic level, moving charge carriers interact with the material's atomic structure. These interactions impede their movement and transfer energy to the material, usually as heat. This is why current-carrying wires, connectors and electrical loads can become warm.
3.2 Factors affecting conductor resistance
For a uniform conductor at a stated temperature, resistance is proportional to length and inversely proportional to cross-sectional area. The material's resistivity also matters.
Aircraft cable selection therefore considers current-carrying capacity, voltage drop, temperature rating, installation environment, mechanical strength, weight and applicable aircraft design requirements. A conductor cannot be selected by cross-sectional area alone.
3.3 Contact and connection resistance
Electrical connections are potential weak points. Corrosion, contamination, loose fasteners, damaged terminals, poor crimping and vibration can increase contact resistance. Even a small resistance can create substantial local heating when current is high.
For example, a degraded connector carrying 20 A with a contact resistance of 0.05 Ω dissipates 20 W at the connection. That heat is concentrated in a small area and can damage insulation or surrounding structure. This is one reason why inspection of connectors, bonding straps and cable terminations is important.
3.4 Temperature effects
For many metals over a limited temperature range, resistance can be approximated by:
Here α is the temperature coefficient of resistance for the material near the reference temperature. The equation is an approximation; material data and the actual temperature range matter. The key principle is that heating a metallic conductor generally increases its resistance, which can alter voltage drop and power dissipation.
4. Ohm's law, electrical power and energy
4.1 Ohm's law
For an ohmic conductor under constant physical conditions, current is directly proportional to the potential difference across it. The constant ratio of voltage to current is resistance.
Ohm's law is straightforward but only applies in this linear form to components whose resistance remains effectively constant over the operating range. Lamps, semiconductor devices and some electronic components may have non-linear voltage-current characteristics.
4.2 Electrical power
Power is the rate at which energy is transferred or converted. In a DC circuit:
Combining this with Ohm's law gives two useful alternatives:
Power is measured in watts (W). Electrical loads are often rated by power or by voltage and current. A 28 V load drawing 5 A consumes 140 W under those conditions.
4.3 Electrical energy
Energy is power multiplied by time. If power is constant, a 100 W load operating for 2 hours uses 200 Wh of energy. Battery capacity is commonly expressed in ampere-hours (Ah), but Ah is a measure of charge capacity at specified conditions, not directly a measure of energy. To estimate energy in watt-hours, voltage must also be considered.
4.4 Efficiency
Not all input electrical power becomes useful output. Some is lost as heat, magnetic losses, friction or other unwanted effects. Efficiency is the ratio of useful output power to input power, normally expressed as a percentage.
A motor receiving 500 W and delivering 425 W of mechanical output has an efficiency of 85%. The remaining 75 W is lost, largely as heat and other losses. Thermal management is important because excessive temperature can degrade insulation and shorten component life.
5. Series, parallel and combined circuits
5.1 Series circuits
Components are connected end-to-end so that there is only one path for current. The same current flows through every component. The supply voltage is divided among the components according to their resistances.
- Total resistance is the sum of individual resistances.
- The current is common to all series components.
- The sum of voltage drops equals the supply voltage in an ideal closed loop.
- An open circuit at any point interrupts current through the entire series path.
5.2 Parallel circuits
In a parallel circuit, components are connected across the same two nodes. Each branch has the same potential difference, while current divides between branches according to their resistance.
- Voltage across each branch is equal to the supply voltage in an ideal circuit.
- Total current is the sum of branch currents.
- Adding another parallel branch reduces the total equivalent resistance.
- An open circuit in one branch does not necessarily interrupt the other branches.
For two parallel resistors, the equivalent resistance can also be calculated as \(Rₜ = (R₁R₂)/(R₁+R₂)\). The total resistance is always less than the smallest individual branch resistance when positive resistances are connected in parallel.
5.3 Series-parallel circuits
Many practical circuits combine series and parallel connections. Reduce the circuit in stages: identify groups that are clearly in series or parallel, calculate their equivalent resistance, redraw the simplified circuit and continue until one equivalent resistance remains. Then use Ohm's law to find total current and work backward to find branch currents and voltage drops.
5.4 Why parallel distribution is common in aircraft
Aircraft electrical distribution is designed so that many loads can receive power from common busbars while remaining separately protected and controlled. Parallel distribution means one failed load or an open branch need not disable every other load. Actual aircraft systems use engineered bus architecture, switching, protection and redundancy; they are more complex than a simple classroom parallel circuit.
6. Kirchhoff's laws and circuit analysis
6.1 Kirchhoff's Current Law (KCL)
At any junction in a circuit, the total current entering equals the total current leaving, assuming no charge is accumulating at the junction. This is a statement of conservation of electric charge.
If 8 A enters a junction and two branches carry 3 A and 5 A away, KCL is satisfied. If the measured currents do not balance, consider measurement error, an unrecognised branch, transient behaviour or a fault.
6.2 Kirchhoff's Voltage Law (KVL)
For a closed loop, the algebraic sum of all voltage rises and drops is zero. This follows from conservation of energy: a charge returning to its starting point has no net energy gain or loss.
For a 24 V source feeding two series resistors with drops of 9 V and 15 V, the sum of the drops is 24 V. If the measured drops total 20 V, the discrepancy must be investigated rather than ignored.
6.3 Applying the laws
- Identify the circuit nodes and branches.
- Choose a reference direction for each unknown current. A negative calculated result means the actual direction is opposite to the assumed direction.
- Apply KCL at junctions to relate branch currents.
- Apply KVL around independent loops to relate voltage rises and drops.
- Use component relationships such as Ohm's law to solve the equations.
- Check that the final values satisfy both current and voltage conservation.
7. Switches, relays, contactors and solenoids
7.1 Switches
A switch controls whether a conducting path is open or closed. In the closed position, contacts provide a low-resistance path; in the open position, the path is interrupted. Switches may be manually operated, mechanically actuated or controlled electrically.
Switch selection considers rated voltage, continuous current, transient current, DC or AC service, number of operations, environmental exposure and the type of load. Breaking an inductive load can produce an arc because stored magnetic energy attempts to maintain current. Switch contacts must be designed for the intended duty.
7.2 Relays
A relay is an electrically operated switch. A relatively small control current energises a coil, producing a magnetic field that moves an armature and changes the state of one or more contacts. This allows a low-power control circuit to switch a separate load circuit.
Relays may have normally open (NO), normally closed (NC) or changeover contacts. When the coil is de-energised, NO contacts are open and NC contacts are closed. Energising the coil changes the contact state. The exact configuration is shown on the component diagram or aircraft wiring documentation.
7.3 Contactors
A contactor is a switching device designed to control relatively high-current power circuits. Contactors are used where a control signal must connect or disconnect a substantial electrical load. They may incorporate arc-control features, auxiliary contacts and mechanical interlocks. A battery contactor, for example, can connect a battery to an aircraft distribution system when commanded by the appropriate control logic.
7.4 Solenoids
A solenoid uses an electromagnetic coil to produce linear mechanical movement of a plunger or armature. Solenoids can operate latches, valves or mechanical mechanisms. A relay is primarily used to change electrical contacts; a solenoid is generally used to produce mechanical movement, although the distinction can overlap in practical designs.
7.5 Failure considerations
- Contacts can become pitted, burnt, contaminated or welded together.
- Coils can become open-circuit, short-circuit or overheated.
- Mechanical parts can stick due to contamination, corrosion or wear.
- Vibration and poor mounting can cause intermittent operation.
- Incorrect suppression across an inductive coil can affect release time or circuit behaviour.
8. Circuit protection
8.1 Why circuits need protection
Aircraft wiring must be protected against excessive current that could overheat conductors, damage insulation, ignite nearby material or cause loss of electrical services. Overcurrent can result from an overload, short circuit, ground fault, damaged wire, failed component or incorrect installation.
Protection is selected to protect the wiring and system while allowing normal transient loads and expected operating currents. A protective device is not simply chosen to match the equipment's normal current. Its rating and time-current characteristics must be coordinated with the conductor, load, source capability and aircraft design.
8.2 Fuses
A fuse contains an element designed to melt when current and time produce sufficient heating. Once the element melts, the circuit opens. A fuse is normally a one-time protective device and must be replaced with the correct approved type and rating after operation.
8.3 Circuit breakers
A circuit breaker is a resettable protective device that opens a circuit when current exceeds its operating characteristics. Depending on design, it may use thermal, magnetic or combined mechanisms. A thermal breaker responds to heating; a magnetic breaker responds to the magnetic effect of current. Some breakers are designed for particular DC or AC applications and have specified trip curves.
| Device | Operating principle | Key point |
|---|---|---|
| Fuse | Fuse element melts due to excessive heating. | Normally replaced after operation. |
| Thermal circuit breaker | Heating bends or releases a mechanism. | Response depends on current magnitude and duration. |
| Magnetic circuit breaker | Magnetic force operates the trip mechanism. | Can respond rapidly to high fault current. |
| Thermal-magnetic breaker | Combines thermal overload and magnetic high-current response. | Protection characteristics depend on the specific design. |
8.4 Overload versus short circuit
An overload occurs when a circuit draws more current than intended, perhaps because too many loads are connected or a motor is mechanically overloaded. A short circuit is an unintended low-resistance connection between points at different potentials. Short-circuit current can be very high and may rise rapidly, depending on source and circuit impedance.
8.5 Resetting a circuit breaker
A tripped breaker is evidence that the circuit has experienced a condition that caused the protective device to open. Resetting without understanding the cause can re-energise a fault and create a fire risk. Aircraft procedures and the applicable maintenance or operational instructions govern whether a reset is permitted, how many attempts may be made and under what conditions.
8.6 Selective protection and essential services
Protection should isolate the affected circuit while preserving unaffected services wherever possible. A fault on a non-essential branch should not unnecessarily remove power from an essential bus. Aircraft system designers use separate buses, circuit protection, contactors, relays and control logic to manage this risk. The actual architecture differs by aircraft type.
9. Capacitors
9.1 Construction and principle
A capacitor consists of two conducting plates separated by an insulating material called a dielectric. When a voltage is applied, charge accumulates on the plates: one plate becomes positively charged and the other negatively charged. The dielectric prevents direct conduction between the plates while allowing an electric field to be established.
9.2 Capacitance
Capacitance is the ability to store electric charge per unit potential difference. It is measured in farads (F). One farad is a very large capacitance for many practical electronic applications; microfarads (µF), nanofarads (nF) and picofarads (pF) are commonly encountered.
For a parallel-plate capacitor, capacitance increases with plate area and dielectric permittivity, and decreases as plate separation increases. In practical capacitors, the construction, dielectric material, voltage rating, temperature range, leakage current and tolerance determine suitability.
9.3 Charging and discharging
When a capacitor is connected to a DC source through a resistor, current initially flows as charge builds on the plates. As capacitor voltage rises, the voltage difference driving further charging current becomes smaller. In an ideal simple RC circuit, capacitor voltage approaches the supply voltage exponentially rather than reaching it instantaneously.
The time constant is the product of resistance and capacitance:
After one time constant, a charging capacitor reaches approximately 63.2% of its final voltage. After about five time constants, it is very close to its final value (over 99%). During discharge through a resistor, the voltage falls exponentially; after one time constant it has fallen to about 36.8% of its initial value.
9.4 Capacitors in series and parallel
| Connection | Equivalent capacitance | Useful observation |
|---|---|---|
| Parallel | Cₜ = C₁ + C₂ + C₃ + … | Capacitances add; the total capacitance increases. |
| Series | 1/Cₜ = 1/C₁ + 1/C₂ + 1/C₃ + … | Equivalent capacitance is lower than the smallest individual capacitor. |
9.5 Energy stored
The stored energy increases with capacitance and with the square of voltage. Doubling voltage, with capacitance unchanged, increases stored energy by a factor of four. This is important when considering high-voltage power supplies and stored-energy hazards.
9.6 Practical uses
10. Applying electrical fundamentals to aircraft
10.1 Aircraft electrical loads
Aircraft electrical loads include lighting, instruments, communication and navigation equipment, pumps, actuators, heating elements, motors, control computers and cabin services. Their electrical requirements differ widely. Some are continuous loads; others operate intermittently or draw a high starting current. Some are essential for safe flight, while others may be shed when available power is limited.
Electrical distribution must account for normal load, peak load, starting transients, source capability, wiring limits, environmental conditions and failure cases. The system must also avoid unacceptable interference with sensitive equipment.
10.2 Voltage drop in wiring
Every real conductor has resistance. When current flows, a voltage drop occurs along the conductor. Excessive voltage drop can cause a load to operate incorrectly, run slowly, dim or fail to start. The voltage available at the load is the source voltage minus the drops in the supply and return paths.
Both the positive and return conductors contribute to the total path resistance unless the aircraft structure is part of the approved return path. Bonding and grounding arrangements must follow the aircraft design; do not assume the airframe is always the electrical return conductor.
10.3 Short circuits, open circuits and high resistance faults
| Fault type | Electrical effect | Possible indication |
|---|---|---|
| Open circuit | Path is broken; current in that path stops. | Load inoperative, no current, possible warning depending on monitoring. |
| Short circuit | Unintended low-resistance path between points of different potential. | High current, protective device operation, heat or smoke. |
| High-resistance connection | Unwanted resistance causes voltage drop and local heating. | Intermittent operation, dim lighting, hot connector, abnormal voltage drop. |
| Ground fault | Unintended connection to structure or ground reference. | May cause protective device operation or abnormal current paths. |
| Intermittent fault | Connection changes with vibration, temperature or movement. | Fault appears and disappears; difficult to reproduce. |
10.4 A systematic troubleshooting mindset
At pilot level, the correct response is to recognise the indication, assess its operational significance and follow approved procedures. At maintenance level, troubleshooting requires approved documentation, isolation, test equipment and safe work practices. A sound diagnostic sequence is:
- Confirm the reported symptom and operating conditions.
- Consult the applicable aircraft documentation and fault-isolation procedure.
- Identify the affected supply, bus, protective device and load.
- Check whether the fault is an open circuit, short circuit, excessive resistance or control issue.
- Use approved test points and correctly rated equipment.
- Isolate and rectify the fault in accordance with approved maintenance data.
- Carry out required operational tests and record the work.
10.5 Why the foundations matter
In the next chapter, batteries and electromagnetic machines will be studied. Chapter 18 will apply circuit principles to aircraft DC power distribution. Later, AC generation, transformers, motors and electronics will build on the same foundations. A student who can reason confidently about current paths, voltage drops, power, resistance and protection will find those systems far easier to understand.
11. Electrical sources, internal resistance and terminal voltage
11.1 Ideal and real sources
An ideal voltage source maintains a constant voltage regardless of current. Real batteries and generators have internal resistance and other losses. When a load draws current, some of the generated EMF is used internally, so terminal voltage may fall.
For a simple source model with EMF E, internal resistance r, load resistance R and current I:
When a battery supplies current, terminal voltage is generally below its open-circuit EMF because of internal voltage drop. During charging, the applied terminal voltage must overcome the battery EMF and internal losses. Battery chemistry, temperature, state of charge, age and current demand all influence behaviour.
11.2 Why voltage can collapse under load
A battery may show a plausible open-circuit voltage yet fail to supply a high-current load. Possible causes include increased internal resistance, a poor external connection, low state of charge or unsuitable temperature. A correctly performed load test can reveal behaviour that an unloaded measurement cannot.
11.3 Short-circuit current
A short circuit creates an unintended low-resistance path between points at different potentials. Current is limited by total source, wiring and fault-path impedance—not by the intended load. Even a low-voltage aircraft battery can deliver enough current to cause intense heating, molten metal and arcing.
The simplified relationship I = E/(r + Rwiring + Rfault) illustrates why a low-resistance fault can produce very high current. Real fault current also depends on transient effects, source characteristics and protective-device response.
12. Practical circuit measurement and diagnostic reasoning
12.1 Measure with a question in mind
A measurement is useful only when it tests a defined hypothesis. Before selecting a meter, establish whether the task is to measure supply voltage, voltage drop, current, continuity or resistance. Confirm the circuit's energy state, instrument range, connection points and applicable procedure.
12.2 Continuity and resistance checks
A continuity check determines whether a path is complete enough to pass the meter's small test current. It does not prove that the path can carry the required load. A damaged conductor, corroded joint or poor crimp may pass a low-current continuity test yet develop excessive voltage drop under load.
Resistance measurements require the circuit to be de-energised and isolated as specified. Parallel paths can distort a reading because the meter may see alternate routes through connected components. Sensitive electronic equipment can also be damaged by inappropriate test voltages.
12.3 Voltage-drop testing
Voltage-drop testing measures potential difference across a conductor or connection while the circuit operates under an appropriate load. A sound low-resistance connection should have a small drop; a degraded connection may show a larger one.
Measure across the specific segment being evaluated. Test points and allowable limits must come from approved data.
12.4 Simplified fault patterns
| Observation | Possible interpretation | Why further testing is needed |
|---|---|---|
| Supply present at source but absent at load | Open conductor, switch, protective device or connector. | Trace the circuit in sections; check the return path and control state. |
| Protective device opens immediately | Possible short circuit or severe overload. | Do not repeatedly reset; follow approved isolation procedures. |
| Load weak; connector hot | Possible high-resistance connection or damaged conductor. | Check voltage drop under load and inspect using approved procedures. |
| Fault appears during vibration | Possible intermittent conductor, connector or chafing fault. | Use approved inspection and test procedures. |
12.5 Meter connection errors
- Connecting an ammeter in parallel can create a short circuit through the meter.
- Connecting a voltmeter in series can prevent normal load current.
- Measuring resistance on an energised circuit can damage the meter and create a hazard.
- Using the wrong current input socket or range can damage the instrument.
- Leaving test leads in the current socket and then attempting a voltage measurement is an avoidable error.
13. Aircraft wiring, bonding, grounding and interference
13.1 Wiring is an aircraft system
Aircraft wiring is often described as the Electrical Wiring Interconnection System (EWIS). It includes wires, cables, bundles, connectors, terminals, splices, clamps, conduits, protective coverings, supports and bonding features. It must remain reliable through vibration, temperature cycling, moisture exposure, pressure changes, structural movement and maintenance access.
Wire selection is not based on current alone. Engineers consider conductor material and area, insulation temperature and voltage ratings, allowable voltage drop, bundle derating, ambient temperature, routing, fluid exposure, abrasion, fire zones, weight and consequences of failure. The same wire size may not be suitable in every installation.
13.2 Routing and support
Wiring must be supported so it does not sag, chafe against structure, interfere with controls or become damaged during maintenance. Clearance is important near flight-control cables, moving mechanisms, hot ducts, sharp edges, fluid lines and access panels. Harnesses must not be used as handholds or left where cargo or equipment can crush them.
High-vibration and high-temperature zones—such as engine nacelles, pylons, landing-gear bays and APU compartments—require particular attention. Areas exposed to moisture, hydraulic fluid, fuel, cleaning agents or battery electrolyte can accelerate insulation and connector deterioration.
13.3 Bonding versus grounding
13.4 Screening and electromagnetic compatibility
High-current switching, motors, ignition systems, transmitters and power converters can produce electromagnetic fields. Sensitive signals can be disturbed if wiring is routed or shielded incorrectly. Screening uses conductive shielding around a cable or component to reduce coupling of unwanted electromagnetic energy.
The screen's termination arrangement matters. Whether it is connected at one end or both ends depends on circuit frequency, installation design and equipment specification. Never assume a universal shield-termination rule.
13.5 Typical wiring defects
- Chafed, cracked, cut or heat-discoloured insulation.
- Loose, corroded, contaminated or overheated connectors.
- Broken strands, poor crimps or unsupported splices.
- Inadequate clamps, damaged grommets or missing protective sleeving.
- Wire bundles routed too close to moving parts or hot surfaces.
- Evidence of fluid ingress, arcing, smoke or burning odour.
These defects can create open circuits, short circuits, intermittent faults, high-resistance heating or cross-system interference. Inspection and rectification require approved maintenance data.
14. Circuit protection — deeper engineering principles
14.1 Protection is coordinated with the wire
The primary purpose of branch-circuit protection is to prevent wiring from being exposed to damaging overcurrent for longer than its design permits. The protective device must tolerate normal current and expected transients while opening the circuit before the wire or installation is damaged. A device rated too high may fail to protect the conductor; one rated too low may nuisance-trip.
14.2 Time-current characteristics
Protective devices do not normally trip at one exact current independent of time. A modest overload may take longer to cause operation, while a large fault current may cause rapid operation. A time-current curve describes this relationship. Two breakers with the same nominal current rating can have different characteristics.
14.3 Interrupting capacity and DC arcs
A protective device must safely interrupt the available fault current at the circuit voltage and current type for which it is rated. DC arcs can be difficult to extinguish because DC current does not naturally pass through zero each half-cycle as AC does. Device construction, voltage rating and interrupting capacity therefore matter.
14.4 Nuisance tripping and repeated resetting
A breaker that opens during a normal transient may be incorrectly selected, degraded or responding to a real abnormal condition. The correct response is not to install a higher-rated breaker or repeatedly reset it. The cause and approved rating must be established using aircraft data.
14.5 Fault isolation and essential loads
Aircraft electrical systems are arranged so faults can be isolated and essential services preserved where practicable. Bus separation, redundant sources, contactors, circuit protection and load-shedding logic contribute. The architecture is aircraft-specific and is developed in Chapter 18.
15. Capacitors — deeper understanding
15.1 Dielectric and breakdown voltage
The dielectric polarises in the electric field and influences capacitance, leakage and voltage capability. If the electric field exceeds the dielectric's withstand capability, breakdown can occur, producing a conductive path and potentially destroying the component. Capacitors therefore have specified working-voltage and temperature ratings.
15.2 Series and parallel combinations
Capacitors in parallel have the same voltage and their stored charges add, so capacitances add. Capacitors in series carry equal charge in the ideal case while the applied voltage is shared. Equivalent series capacitance is less than the smallest individual capacitance.
15.3 RC charging curve
For a simple series RC circuit connected to a DC step source:
During discharge from initial voltage V0:
The time constant τ = RC is a measure of response speed. At one time constant, charging reaches about 63.2% of final value and discharging falls to about 36.8% of initial value.
15.4 Capacitor behaviour with AC
A capacitor allows alternating current in a circuit because its charge and discharge cycle repeatedly. Its capacitive reactance is:
As frequency increases, capacitive reactance decreases. As capacitance increases, capacitive reactance also decreases. This principle is used in filtering and signal coupling. Full AC circuit analysis belongs in Chapter 19.
15.5 Practical capacitor failures
Capacitors can fail open-circuit, short-circuit, leak, lose capacitance or develop increased equivalent series resistance (ESR). Heat, age, vibration, voltage stress and manufacturing defects can contribute. A degraded filter capacitor may allow excessive ripple; a changed capacitance in a timing circuit can alter the intended delay.
16. Additional worked examples — applied electrical reasoning
Example 16 — Source internal resistance
A source has EMF 28 V and internal resistance 0.2 Ω. It supplies a 6.8 Ω load.
Vterminal = 28 − (4 × 0.2) = 27.2 V
The load receives 27.2 V in this simplified model; 0.8 V is dropped internally.
Example 17 — Power lost inside a source
This power becomes heat inside the source.
Example 18 — Branch currents in parallel
A 24 V supply feeds 8 Ω and 12 Ω resistors in parallel.
I2 = 24/12 = 2 A
Itotal = 3 + 2 = 5 A
The lower-resistance branch takes the larger current. KCL confirms the total.
Example 19 — Parallel equivalent resistance
Total current is 24/4.8 = 5 A, matching the branch-current calculation.
Example 20 — Power dissipated in a connector
A connection has resistance 0.03 Ω and carries 25 A.
This is significant local heating for a small connection.
Example 21 — Round-trip cable voltage drop
A load is 5 m from its source. Positive and return conductors are each 5 m long, each with resistance 0.01 Ω/m. Current is 10 A.
Vdrop = 10 × 0.10 = 1.0 V
Counting only the outgoing wire understates the drop. Include the return path unless the approved design uses another path.
Example 22 — Load current and power
A 28 V heater has resistance 14 Ω at its stated operating condition.
P = 28 × 2 = 56 W
For a real heater, resistance may change as the element warms; operating condition matters.
Example 23 — Capacitor combinations
Two capacitors of 20 µF and 30 µF are connected in parallel, then in series.
Series: Ctotal = (20 × 30)/(20 + 30) = 12 µF
Example 24 — Charging after two time constants
A capacitor charges through a resistor from a 28 V source. After two time constants:
That is about 86.5% of final voltage.
Example 25 — Discharging after one time constant
A capacitor initially charged to 28 V discharges through a resistor.
About 36.8% of initial voltage remains. Approved safe-discharge procedures still apply.
Example 26 — Breaker opens after a load is added
A branch normally draws 7 A. A second load is connected and total current becomes 11 A. The breaker opens after a short period. What can be concluded?
Example 27 — Diagnosing a dim lamp
A lamp is dim but its supply bus indication is normal. Possible causes?
Example 28 — Why continuity can mislead
A wire passes a continuity test but a connected motor operates slowly. Explain.
Example 29 — Capacitor energy and voltage
A capacitor is charged to 40 V. If voltage doubles to 80 V with capacitance unchanged:
Stored energy becomes four times greater.
Example 30 — Interpreting a hot connector
A connector is unusually hot and the load intermittently drops out. Which mechanism links these symptoms?
Worked examples and operational scenarios
Example 1 — Current from Ohm's law
A 24 V supply is connected across a 12 Ω resistive load. Find the current.
Example 2 — Resistance from measured values
A load has 28 V across it and draws 4 A. Its effective resistance is:
Example 3 — Power consumed by an aircraft load
A 28 V equipment unit draws 3.5 A. Find its electrical input power.
Example 4 — Current and energy over time
A 2 A load operates for 45 minutes. How much charge passes through it?
In coulombs, 45 minutes is 2700 seconds, so Q = 2 × 2700 = 5400 C. Ah is convenient for battery charge calculations; coulombs are the SI unit.
Example 5 — Series resistance
Three resistors of 2 Ω, 4 Ω and 6 Ω are connected in series across 24 V.
I = 24/12 = 2 A
Voltage drops are 4 V, 8 V and 12 V respectively. Their sum is 24 V, satisfying KVL.
Example 6 — Parallel resistance
Two resistors of 6 Ω and 3 Ω are connected in parallel.
Rₜ = 2 Ω
Across a 12 V supply, total current is 6 A. Branch currents are 2 A through the 6 Ω resistor and 4 A through the 3 Ω resistor. Their sum is 6 A, satisfying KCL.
Example 7 — Voltage drop in a cable
A circuit carries 8 A through a total cable-loop resistance of 0.25 Ω. Calculate the voltage drop.
If the source is 28 V, the load receives approximately 26 V, assuming no other drops. Whether this is acceptable depends on the equipment's specified input range.
Example 8 — Heating at a poor connection
A connector has developed 0.08 Ω resistance while carrying 15 A.
Eighteen watts concentrated in a small connector can cause significant heating. The fault should be addressed using approved maintenance procedures, not by simply increasing circuit-breaker rating.
Example 9 — Circuit-breaker rating reasoning
A load normally draws 6 A. Does this mean a 6 A circuit breaker is automatically correct?
Example 10 — Capacitor charge
A 100 µF capacitor is charged to 28 V. Calculate the stored charge.
This is 2.8 mC.
Example 11 — RC time constant
A 10 kΩ resistor is connected in series with a 100 µF capacitor.
After approximately 1 second, the capacitor has reached 63.2% of its final voltage during ideal charging.
Example 12 — Capacitor stored energy
A 470 µF capacitor is charged to 28 V.
E ≈ 0.184 J
The energy is modest in this example, but the same relationship shows why stored energy rises rapidly with voltage.
Example 13 — Parallel load failure
Three cabin lights are connected on separately protected parallel branches. One lamp fails open circuit. What happens to the other lamps?
Example 14 — Open circuit versus short circuit
A cockpit indication shows that a lamp is not illuminated. Is the fault necessarily an open circuit?
Example 15 — Electrical load and power budget
A 28 V bus supplies three loads drawing 2 A, 4 A and 5 A. If all operate simultaneously, total current and ideal total power are:
P total = 28 × 11 = 308 W
This is a basic load estimate. Real aircraft load analysis also considers duty cycle, power factor for AC loads, transient demand, source limits and contingency cases.
Chapter summary and revision checklist
Core principles to remember
- Electricity in metallic conductors is associated with the movement of mobile electrons; conventional current is defined in the opposite direction.
- Current is charge flow per unit time and is measured in amperes.
- Resistance opposes current and depends on material, length, cross-sectional area and temperature.
- Ohm's law relates voltage, current and resistance for ohmic conditions.
- Power is the rate of energy transfer; in a DC circuit P = VI.
- Series circuits have a common current; parallel branches share the same voltage.
- KCL expresses conservation of charge; KVL expresses conservation of energy around a loop.
- Relays and contactors use electromagnetic action to switch circuits.
- Fuses and circuit breakers protect wiring from excessive current, but their selection and operation must follow approved design data.
- Capacitors store charge and energy in an electric field; they may retain a charge after power is removed.
- Aircraft electrical faults include open circuits, short circuits, high-resistance connections and intermittent faults.
Formula sheet
| Relationship | Formula | Typical use |
|---|---|---|
| Charge and current | Q = I × t | Charge transferred over time. |
| Ohm's law | V = IR | Voltage, current or resistance. |
| Power | P = VI = I²R = V²/R | Electrical power in a resistive DC circuit. |
| Energy | E = Pt | Energy transferred over time. |
| Conductor resistance | R = ρL/A | Effect of material and geometry. |
| Series resistance | Rₜ = ΣR | Resistors in series. |
| Parallel resistance | 1/Rₜ = Σ(1/R) | Resistors in parallel. |
| Capacitance | C = Q/V | Charge stored per volt. |
| RC time constant | τ = RC | Charging/discharging response. |
| Capacitor energy | E = ½CV² | Stored electric-field energy. |
Systems-thinking summary
For any aircraft electrical problem, ask five questions: where does energy originate; what path does current follow; what controls that path; what load converts the energy; and what protection limits the consequences of a fault? Then consider whether the symptom reflects loss of supply, loss of return, excessive resistance, an unintended low-resistance path or incorrect control logic.
Do not confuse a component's normal function with the behaviour of the complete system. A relay may operate while its power contacts are defective; a breaker may open correctly because the load or wiring is faulty; a battery may show normal open-circuit voltage but fail under load. Good electrical reasoning considers the entire circuit.
Before moving to Chapter 17, you should be able to…
- Explain the difference between EMF and potential difference.
- Calculate current, resistance, power and energy in simple DC circuits.
- Calculate equivalent resistance in series and parallel networks.
- Use KCL and KVL to check a circuit.
- Explain why an ammeter is connected in series and a voltmeter in parallel.
- Distinguish overloads, short circuits, open circuits and high-resistance faults.
- Explain why resetting a tripped breaker requires procedural control.
- Describe how a capacitor stores charge and why it may remain hazardous after isolation.
Knowledge check — 12 questions
Further study
AeroLearn Rwanda · Aircraft General Knowledge · Electrics and Electronics · Chapter 16 of 35