Loading, Load Distribution and Floor Loading
Understanding how cargo is positioned, supported and restrained — and why aircraft floor limits can be exceeded even when the aircraft’s total mass remains within its permitted limit.
1. Learning outcomes
By the end of this chapter, you should be able to explain the main cargo loading arrangements and calculate the basic floor loading checks described in Book 6.
- Explain why load distribution matters in addition to total aircraft mass and CG.
- Describe the purpose and general features of aircraft cargo compartments.
- Distinguish containerised, palletised and bulk cargo.
- Explain the purpose of cargo power-drive systems, rollers, guides, stops, locks and tie-down fittings.
- Describe how linear/running load limitations protect underfloor frames.
- Calculate maximum, intermediate and minimum running loads for different cargo orientations.
- Explain area-load intensity and distinguish uniformly distributed from concentrated loads.
- Calculate floor loading intensity and determine whether a load orientation is within a stated training limit.
- Explain the purpose of approved load spreaders and why they do not remove the need to comply with aircraft-specific limits.
2. Principles of aircraft loading
Aircraft loading is the controlled placement of passengers, baggage, cargo, mail, equipment and other load items in the aircraft. The load must be distributed so that the aircraft remains within its approved mass and balance envelope and the structure can safely support the forces transmitted by the load.
2.1 Total mass is only one part of the problem
An aircraft may be below its maximum take-off mass but still be loaded incorrectly. For example, a very heavy item placed on a small contact area may exceed the floor panel’s local loading limit. A long item placed in the wrong orientation may overload underfloor frames even when the floor area loading appears acceptable.
2.2 Structural consequences of excessive floor loading
This course explains that excessive loading can cause visible floor-panel creasing and local indentations and can significantly accelerate structural fatigue. Fatigue is cumulative; repeated overstressing can progressively weaken the structure and may ultimately lead to major structural failure.
2.3 Three questions before accepting a load
- Is the cargo mass and position permitted for the aircraft and compartment?
- Is the load spread over enough floor length and area to remain within local structural limits?
- Can the cargo be restrained against movement in all required directions during flight and ground handling?
3. Aircraft cargo compartments
This course describes lower-deck compartments as spaces used for baggage and cargo. The source notes that these compartments commonly have fire-resistant sidewalls, ceilings and walkways; are usually pressurised and heated; and typically have fire detection and protection equipment.
3.1 Compartment limits
Each cargo compartment may have its own maximum floor loading and maximum running-load value. In addition, the compartment may have a maximum total mass. These limits protect different structural elements and must be checked separately.
| Limit type | What it controls | Why it matters |
|---|---|---|
| Maximum compartment mass | Total mass carried in the compartment | Prevents overloading the compartment and its supporting structure. |
| Area load intensity | Mass per unit floor area | Protects floor panels from excessive local pressure. |
| Linear / running load | Mass per unit length | Protects underfloor frames and supporting members. |
| Container / pallet limit | Mass and floor loading of a specific ULD | Prevents overloading the ULD itself as well as the aircraft interface. |
| Restraint limit | Loads transmitted to locks, nets, tie-downs and fittings | Prevents cargo shifting and structural damage. |
3.2 Cargo compartment arrangement
Compartments are not necessarily interchangeable. Door dimensions, floor geometry, loading system, fire protection, compartment classification and approved cargo types may differ. An item that physically fits through a cargo door is not automatically acceptable for that compartment.
4. Containerised and palletised cargo
4.1 Containerised cargo
This course describes standard-size containers designed to fit into and lock within the cargo compartment. These containers are generally referred to as Unit Load Devices (ULDs). Each container has an individual maximum mass limit and an individual floor-loading limit (mass per unit area).
Containerisation allows compatible cargo to be assembled into a unit before aircraft loading. The container is then moved into the compartment and secured through the aircraft’s approved cargo restraint system. The ULD’s own limitations and the aircraft compartment’s limitations both apply.
4.2 Palletised cargo
Cargo may be built up on a standard aircraft pallet and restrained with cargo nets or straps (strops). This course notes that the forward area of the forward cargo compartment is typically configured to accept palletised freight in the example aircraft context.
The pallet provides a base on which individual pieces are arranged. The pallet and net combination must be compatible with the aircraft and its approved loading system. The pallet’s maximum gross mass, contour, floor interface and restraint provisions must be respected.
4.3 Containerised versus palletised
| Feature | Containerised cargo | Palletised cargo |
|---|---|---|
| Load base | Rigid or semi-rigid container | Standard aircraft pallet |
| Restraint interface | Container-compatible locks and guides | Net/strops and pallet-compatible restraints |
| Load enclosure | Container sides and contour enclose the load | Net or straps restrain cargo on pallet |
| Key checks | Container mass, floor intensity, contour and locks | Pallet mass, net compatibility, contour and restraint |
5. Bulk cargo
This course describes bulk cargo as cargo loaded loosely in the aft area of the rear cargo compartment in its example arrangement. It is separated from containers by a restraining net attached to the floor, ceiling and sidewalls.
5.1 Why bulk cargo needs restraint
Loose items can shift during acceleration, deceleration, turbulence, take-off, landing and changes in aircraft attitude. A shift can damage aircraft systems or structure, injure personnel during handling, and alter the aircraft’s CG. Restraint prevents the load from moving outside its approved space.
5.2 Compartment authorisation
Bulk loading is only permitted where the aircraft’s approved data and operator procedures authorise it. FAA AC 120-85B provides supplementary guidance on cargo loading, restraint, load distribution, clearance from aircraft systems and the use of nets. This is US guidance, not Rwanda CAA regulation.
6. Cargo handling systems and restraint
This course describes powered cargo-handling systems in forward and aft compartments. Power-drive units (PDUs) are mounted in the floor and controlled from a panel near the cargo door. They move containers or pallets laterally and longitudinally in the doorway area and longitudinally within the compartment.
6.1 Components and their purpose
| Component | Function |
|---|---|
| Power-drive units (PDUs) | Provide powered movement of compatible containers and pallets during loading/unloading. |
| Rollers / ball mats | Reduce friction and allow compatible ULDs to be moved along the cargo floor. |
| Guides / side guides | Keep the ULD aligned with the intended path and loading position. |
| Stops / end stops | Prevent overrun and help define the correct position. |
| Locks / latches | Secure ULDs to the aircraft cargo system against movement. |
| Tie-down fittings | Provide approved attachment points for straps or other restraint devices. |
| Nets / strops | Restrain palletised or bulk cargo as approved. |
6.2 Restraint is a flight-safety requirement
In flight, cargo is subjected to acceleration forces. The restraint system must prevent unacceptable movement in the directions and load cases specified by the aircraft design and operator procedures. Cargo restraint is not simply to stop freight from sliding on the floor; it also prevents loads being transferred into areas or systems not designed to carry them.
For a ULD system, the locks and restraint devices must be compatible with the ULD and correctly engaged. For palletised cargo, the net or strop arrangement must be suitable for the pallet and load. For bulk cargo, approved nets and barriers must be used as required.

6.3 Loading system condition
Missing, damaged or inoperative rollers, locks, guides, stops, tie-down fittings or nets can compromise the loading system. FAA AC 120-85B discusses training, inspection and reporting of damaged or missing cargo restraint devices. The operator’s maintenance and operational procedures determine whether the system is serviceable and what action is required.
7. Floor loading limitations
The floors of passenger cabins and cargo compartments are limited in the loads they can carry. This course divides floor loading into two principal measures: linear (running) load and area load intensity. They protect different structural elements and both may apply to the same cargo item.
7.1 Why a floor has more than one limit
Imagine a heavy narrow machine. It may be spread over a long length, so the running load is acceptable, but its small footprint may concentrate too much pressure on the floor panel. Conversely, a broad heavy item may have an acceptable area intensity but place too much load on a short length of underfloor frame.
8. Linear / running loads
This course defines the linear or running-load limitation as the total load permitted in any one unit of length of the aircraft floor, irrespective of load width. It is expressed in units such as kg per linear inch, kg per foot or kg per metre. Its purpose is to protect underfloor frames from excessive loading.
8.1 Orientation changes the running load
The same rectangular item can produce different running loads depending on which dimension lies across the floor beams. This course demonstrates that rotating a load through 90 degrees can change the effective length used in the calculation. The least linear loading occurs when the longest length is placed at right angles to the floor beams, thereby spreading the load across more supporting members.
8.2 Maximum, intermediate and minimum running loads
For a rectangular load with three relevant dimensions in the floor plane/along the compartment as applicable to the exercise, calculate the load divided by each candidate length. The shortest length produces the maximum running load; the intermediate length produces the intermediate value; and the longest length produces the minimum value.
| Calculation | Formula | Interpretation |
|---|---|---|
| Maximum running load | Mass ÷ shortest length | Most concentrated linear arrangement. |
| Intermediate running load | Mass ÷ intermediate length | Intermediate orientation. |
| Minimum running load | Mass ÷ longest length | Least concentrated linear arrangement. |
9. Area load intensity
Area-load limitations protect aircraft floor panels. This course identifies two permitted load-intensity categories: uniformly distributed (UD) loads and concentrated loads. The floor intensity is calculated by dividing the cargo mass by the contact area over which that mass is supported.
9.1 Uniformly distributed (UD) loads
This course describes general floor-loading limits for cargo as UD loads, expressed as an allowable mass per unit area. When the load or series of loads is within the allowable UD limit for the floor area on which it rests, the source says it remains subject to two further checks: linear-load limits and individual/accumulated compartment-load limits.
9.2 Concentrated loads
A concentrated load has an intensity greater than the permitted UD load intensity. This course explains that concentrated loads can be carried when approved load spreaders are used to distribute the load over sufficient area so that the applicable limits are not exceeded.
9.3 Three possible contact areas
For a rectangular package, different faces may be placed against the floor. Each face has a different contact area and therefore a different floor intensity. The smallest face creates the highest intensity; the largest face creates the lowest intensity.
10. Load spreaders and floor protection
When a concentrated load or an item with hard or sharp contact areas is carried, the floor may require protection. This course describes the use of load spreaders to distribute the load over a larger area or length. It notes a common training example of standard two-inch-thick timber spreaders; actual approved materials, dimensions and arrangements must be specified by the aircraft/operator documentation.
10.1 How a spreader works
A spreader increases the effective contact area, length, or both, over which the load is transmitted. If the load is transferred to a larger area, the average floor intensity is reduced. If it is distributed over a greater length across supporting members, the running load may also be reduced.

10.2 What a spreader does not do
- It does not increase the aircraft’s maximum structural mass.
- It does not increase the approved compartment maximum mass.
- It does not automatically make an otherwise prohibited load acceptable.
- It does not replace the requirement to check running load, area intensity, restraints and compartment limits.
- It must be approved for the aircraft and loading arrangement; improvised boards are not an acceptable substitute.
11. Worked examples
These original training examples apply the formulas. The first example follows the structure of the source’s 900 kg cargo exercise; all stated limits are hypothetical training values unless explicitly identified as example values.
Cargo mass 500 kg; supporting length 10 in.
Running load = 500 ÷ 10 = 50 kg/in. If the limit is 45 kg/in, it exceeds the limit.
The same 500 kg item is rotated so the supporting length is 20 in.
Running load = 500 ÷ 20 = 25 kg/in. This is below the 45 kg/in training limit.
500 kg on a 5 ft² footprint.
Intensity = 500 ÷ 5 = 100 kg/ft².
The same 500 kg cargo is supported over 10 ft².
Intensity = 500 ÷ 10 = 50 kg/ft².
This course gives a 900 kg item with dimensions 3 ft × 4 ft × 12 ft. Shortest length = 3 × 12 = 36 in. Maximum running load = 900 ÷ 36 = 25 kg/in. Against the stated 20 kg/in compartment limit, this orientation exceeds the limit.
Intermediate length = 4 × 12 = 48 in. Running load = 900 ÷ 48 = 18.75 kg/in, within the 20 kg/in limit.
Longest length = 12 × 12 = 144 in. Running load = 900 ÷ 144 = 6.25 kg/in, within the 20 kg/in limit.
Smallest face = 3 × 4 = 12 ft². Intensity = 900 ÷ 12 = 75 kg/ft². Against the stated 70 kg/ft² limit, this exceeds the limit.
Medium face = 3 × 12 = 36 ft². Intensity = 900 ÷ 36 = 25 kg/ft², below the 70 kg/ft² limit.
Largest face = 4 × 12 = 48 ft². Intensity = 900 ÷ 48 = 18.75 kg/ft², below the 70 kg/ft² limit.
A 2.5 ft supporting length is 2.5 × 12 = 30 in. A 600 kg load gives 600 ÷ 30 = 20 kg/in.
A limit is expressed in kg/m. A 1.8 m length and 540 kg load give 540 ÷ 1.8 = 300 kg/m. Do not divide by 180 unless the limit is in kg/cm.
A 750 kg item must not exceed 25 kg/m. Required minimum length = 750 ÷ 25 = 30 m. This is a mathematical result only; the approved loading arrangement must establish whether such a spread is practical and permitted.
A 600 kg item must not exceed 300 kg/m². Required minimum contact area = 600 ÷ 300 = 2 m².
Mass 800 kg, support length 4 m, contact area 2 m². Running load = 800 ÷ 4 = 200 kg/m. Area intensity = 800 ÷ 2 = 400 kg/m². If limits are 220 kg/m and 450 kg/m², both checks pass, subject to other limits.
Mass 800 kg, length 5 m, area 1.5 m². Running load = 160 kg/m; area intensity = 533.3 kg/m². With limits 220 kg/m and 450 kg/m², running load passes but area intensity fails. The load is not acceptable in that orientation.
A 400 kg crate has contact faces of 1, 2 and 4 m². Intensities are 400, 200 and 100 kg/m². If the floor limit is 250 kg/m², the 1 m² face fails; 2 m² and 4 m² faces pass the area check.
A 900 kg load has relevant lengths 1.5 m, 2 m and 4 m. Running loads: 600 kg/m, 450 kg/m and 225 kg/m respectively. The longest supporting length gives the lowest linear loading.
Item A: 300 kg over 1.5 m = 200 kg/m. Item B: 500 kg over 5 m = 100 kg/m. Although B is heavier, its running load is lower because it is spread over a greater length.
Two adjacent packages have total mass 700 kg and a combined approved support area of 3.5 m². Average intensity = 700 ÷ 3.5 = 200 kg/m². Check individual contact points and compartment limits as well; an average does not prove every local area is acceptable.
A 500 kg item is initially supported over 0.5 m²: 1,000 kg/m². An approved spreader increases the effective area to 2 m²: 250 kg/m². The average intensity is reduced by a factor of four, but other limits still apply.
A 1,200 kg item must be limited to 600 kg/m². Required effective area = 1,200 ÷ 600 = 2 m².
A 900 kg load initially acts over 1.5 m: 600 kg/m. A spreader arrangement increases the effective load-distribution length to 3 m: 300 kg/m. This assumes the approved spreader transfers the load as intended.
Package 2 ft × 3 ft × 6 ft. Face areas are 6, 12 and 18 ft². For a 720 kg mass, intensities are 120, 60 and 40 kg/ft².
Available contact area is 1.8 m² and the training limit is 500 kg/m². Maximum mathematical mass = 1.8 × 500 = 900 kg, before applying other structural and compartment restrictions.
Supporting length is 2.4 m and limit is 350 kg/m. Maximum mathematical mass = 2.4 × 350 = 840 kg.
A 700 kg item has a running load of 175 kg/m against a 200 kg/m limit, and an area intensity of 700 kg/m² against a 650 kg/m² limit. The area check is limiting and fails.
A 600 kg rectangular item can be supported over 1.2 m or 2.0 m. Running loads are 500 kg/m and 300 kg/m. If the limit is 350 kg/m, orientation A fails and B passes this check.
A 500 kg load is carried over a 10 in dimension: 50 kg/in. Rotated to a 20 in dimension: 25 kg/in. The linear loading is halved.
A 1,000 kg package rests on 20 ft². Intensity = 1,000 ÷ 20 = 50 kg/ft².
A 2 m × 3 m footprint is 6 m². A 900 kg load gives 150 kg/m². Do not confuse the 6 m² area with a 6 m length.
Package A: 300 kg on 1 m² = 300 kg/m². Package B: 300 kg on 2 m² = 150 kg/m². The same mass creates different floor intensity because the contact areas differ.
Mass 500 kg, length 4 m, area 0.8 m². Running load = 125 kg/m; area intensity = 625 kg/m². If limits are 150 kg/m and 500 kg/m², the area intensity fails.
Mass 360 kg and limit 18 kg/in. Minimum length = 360 ÷ 18 = 20 in.
Mass 1,000 kg; candidate supporting lengths 24, 36 and 60 in. Running loads are 41.67, 27.78 and 16.67 kg/in. Compare each orientation with the stated compartment limit.
Mass 1,000 kg; contact faces 2 × 3 ft, 2 × 5 ft and 3 × 5 ft. Areas 6, 10 and 15 ft² produce 166.7, 100 and 66.7 kg/ft².
A 600 kg package rests on two small feet. Dividing by the overall pallet outline may understate the local pressure at each foot if the load is not actually distributed across the full base. Use the approved load-transfer arrangement and effective contact area.
For a 750 kg item, shortest length 1.5 m gives 500 kg/m; longest length 5 m gives 150 kg/m. The long orientation reduces the linear load by 70%.
For the 900 kg, 3 × 4 × 12 ft cargo, the 3 × 4 ft face gives 75 kg/ft² and fails the 70 kg/ft² limit. The 3 × 12 ft face gives 25 kg/ft² and the 4 × 12 ft face gives 18.75 kg/ft². Either larger face passes the area check. Running-load calculations still determine which orientations are acceptable across the underfloor frames.
A 900 kg load is within the compartment total mass limit. However, its smallest-face intensity is 75 kg/ft² against a 70 kg/ft² limit. The total mass being acceptable does not make that orientation acceptable. Repositioning or an approved spreader may be necessary, followed by all other checks.
ULD tare mass is 82 kg and cargo mass is 418 kg. Gross ULD mass = 82 + 418 = 500 kg.
A loaded container has a gross mass of 690 kg and a tare mass of 90 kg. Cargo mass = 690 − 90 = 600 kg.
Three loaded ULDs have gross masses of 620 kg, 710 kg and 580 kg. Compartment total = 620 + 710 + 580 = 1,910 kg. Compare this with the compartment's approved total limit.
Compartment limit is 2,000 kg. Existing load is 1,460 kg. Remaining mathematical capacity = 2,000 − 1,460 = 540 kg. This does not establish that a 540 kg item fits any remaining position or floor limit.
A 480 kg item is within a 600 kg position limit, but adding it to the existing 1,700 kg compartment load produces 2,180 kg against a 2,100 kg compartment limit. The proposed loading fails the compartment total check.
A 1,050 kg loaded pallet is supported over 3.5 m². Average intensity = 1,050 ÷ 3.5 = 300 kg/m². Check pallet and aircraft limits separately.
A 600 kg item has a 20 ft² footprint. Intensity = 600 ÷ 20 = 30 kg/ft². If the compartment limit is 350 kg/m², convert units before comparing: 30 kg/ft² is approximately 323 kg/m².
Use 1 m² ≈ 10.764 ft². A limit of 70 kg/ft² is approximately 70 × 10.764 = 753.5 kg/m². Use the exact conversion convention required by the operator's manual.
A pallet's own maximum gross mass is 1,200 kg, while the aircraft position limit is 1,000 kg. The applicable maximum cannot exceed the more restrictive 1,000 kg position limit, subject to all other restrictions.
A compartment has a total limit of 2,500 kg, but a particular floor zone has a maximum local loading restriction. A 900 kg item may fit within the compartment total but still be prohibited in that floor zone. The position-specific limit must be checked.
A pallet net secures freight to the pallet, while a floor spreader distributes load into the floor. They perform different functions. A net does not by itself correct excessive floor intensity.
A 400 kg item is moved from one compartment position to another. Even if the total aircraft mass is unchanged, the moment and CG may change. Load control must process the position change and update the applicable documentation.
A planned ULD has a gross mass of 650 kg. A substitute ULD weighs 690 kg. The difference is +40 kg. The actual mass and position must be incorporated into the load calculation; the original plan cannot simply be retained unchanged.
A 900 kg machine is supported over 0.9 m², giving 1,000 kg/m². An approved spreader provides an effective contact area of 2.25 m², giving 400 kg/m². The arrangement still requires approval and all other structural checks.
A load is within the aircraft's total mass limit, the CG is within the envelope, the compartment total is acceptable, but one ULD lock is not engaged. The load is not ready for dispatch: the physical restraint condition must be corrected and verified.
12. Advanced loading controls and practical considerations
12.1 ULD identification, compatibility and condition
A Unit Load Device is an aircraft-compatible container or pallet used to group and carry freight. A ULD must be suitable for the aircraft position and loading system. The fact that a ULD can physically be brought to the cargo door does not establish that it is compatible with the aircraft position, contour, restraint arrangement or compartment limits.
Before loading, personnel should follow the operator's ULD acceptance process and verify the identity, type, condition and loading status of the unit. Relevant checks may include structural damage, baseplate condition, net or door condition, restraint fittings, contour, maximum gross mass and any applicable serviceability status. Exact acceptance criteria come from the ULD manufacturer's documentation, operator procedures and applicable industry requirements.

12.2 ULD gross mass, tare mass and cargo mass
When interpreting a ULD mass figure, distinguish the mass of the freight from the mass of the ULD itself. Tare mass is the mass of the empty ULD. Gross mass includes the ULD and its contents. The aircraft loading calculation must use the mass definition required by the operator's system and aircraft documentation; do not add tare mass twice or omit it.
12.3 Contour and clearance
Aircraft fuselage shape limits the usable cross-section of a cargo compartment. A ULD may have a curved or cut-away profile so that it can fit into a lower-deck hold. Cargo built on a pallet may also need to follow a defined contour. Exceeding the permitted contour can cause interference with the aircraft structure, cargo door, lining, systems or adjacent ULDs.
Clearance is not merely a convenience issue. The loading arrangement must preserve the required clearances and must not obstruct fire protection equipment, detection systems, access panels, ventilation paths or other protected areas. The aircraft-specific loading manual defines these restrictions.
12.4 Restraint forces and load direction
During flight and ground operations, cargo may be subjected to acceleration in forward, aft, lateral and vertical directions. Restraint components transfer these forces from the cargo or ULD into approved aircraft fittings and supporting structure. The required restraint arrangement depends on the cargo mass, geometry, centre of gravity, anticipated load directions, attachment-point ratings and the approved loading data.
A tie-down strap is not rated simply by looking at its label and counting straps. The capacity of the complete arrangement depends on the strap, fitting, attachment structure, direction of force, strap angle and the specific method approved for the aircraft. A fitting approved for one direction or loading condition must not be assumed to have the same capability in another direction.

12.5 Loading order, sequencing and cumulative limits
Loading sequence can matter. Items may need to be loaded in a defined order to preserve access, avoid blocking positions, protect fragile items and allow correct engagement of locks. The sequence must also account for the compartment's accumulated mass, local floor loading and the aircraft's overall mass and CG.
For example, a compartment may have a total mass limit while each individual position also has its own maximum. A load can be individually acceptable at a position but the combined mass of all units can exceed the compartment limit. Likewise, the compartment total may be acceptable while one small floor area is overloaded by a concentrated item.
12.6 Load distribution versus load restraint
| Load distribution | Load restraint |
|---|---|
| Determines where the load is supported and how its mass is spread over the floor. | Prevents the load from moving from its approved position. |
| Checks include floor intensity, running load, compartment mass and aircraft CG. | Checks include compatible locks, nets, straps, fittings, directions and approved load capacities. |
| Primarily protects the floor, frames and overall aircraft loading condition. | Protects aircraft structure, systems, occupants and cargo from movement. |
| A spreader may improve the distribution of a concentrated load when approved. | A spreader does not replace locks, nets or tie-downs. |
12.7 Loading changes and reconciliation
Any change from the planned load — including a ULD substitution, offload, position change, cargo mass correction or late addition — must be communicated and processed through the operator's load-control procedure. The final load documentation must reflect the aircraft's actual loaded condition. A load plan is not valid merely because it was correct before loading began.
13. Safety case study — National Airlines Flight 102
This case study is included as supplementary safety learning, not as part of the chapter's original calculation syllabus. It demonstrates why cargo restraint is a safety-critical part of aircraft loading.
On 29 April 2013, National Airlines Flight 102, a Boeing 747-400 converted freighter, crashed shortly after take-off from Bagram, Afghanistan. The FAA summary of the NTSB investigation states that the probable cause was inadequate procedures for restraining special cargo. A vehicle load moved aft and damaged hydraulic systems and horizontal stabilizer drive mechanism components, leaving the aircraft uncontrollable.
13.1 What the investigation highlights
- The load was within the aircraft's overall weight-and-balance envelope, but that did not make the restraint arrangement safe.
- Special cargo required approved restraint procedures and data from the aircraft and cargo-system manufacturers.
- Tie-down fittings and straps have direction- and configuration-dependent capabilities; a fitting cannot be assumed to react loads in every direction.
- Restraint calculations must account for attachment points, strap angles and local structural limits.
- Operator procedures must accurately incorporate safety-critical information from approved manufacturer documentation.

13.2 Lessons for flight operations and load control
- Do not equate an acceptable aircraft total mass with an acceptable cargo arrangement.
- Do not invent restraint methods for unusual or special cargo.
- Ensure the correct aircraft-specific loading and restraint manuals are available to the personnel doing the work.
- Verify that the actual loading and restraint arrangement matches the approved plan.
- Escalate any discrepancy, damaged restraint component or uncertainty before dispatch.
14. Operational loading sequence and control
In practice, safe loading requires coordination between load planning, load control, ramp personnel, cargo handlers and the flight crew. The sequence and responsibilities are established by the operator’s approved procedures.
Identify aircraft type/configuration, available compartments, door/contour constraints and approved loading data.
Confirm actual cargo mass, dimensions, packaging, handling category and any special handling information.
Check compartment maximum mass, ULD/pallet limits, floor intensity, running load and any other local limitations.
Use approved loading positions and orientation. Consider both local floor loads and the aircraft’s overall mass and CG.
Use the approved cargo system, serviceable locks, nets, strops and tie-down points. Do not improvise.
Confirm loaded items, positions and actual weights match the information used for mass-and-balance calculations.
Any load change, substitution, offload or repositioning must be passed to load control and reflected in the approved calculation and documentation.
12.1 Why accurate communication matters
If the load controller calculates using one cargo position but the ramp team loads the item in another, the actual aircraft may differ from the documented condition. The same applies if actual cargo mass differs from planned mass, or if a ULD is substituted. Correct communication closes the gap between the load plan and the aircraft as dispatched.
12.2 Aircraft-specific documents
Depending on the operation, relevant references may include the aircraft Weight and Balance Manual, loading instructions, compartment diagrams, ULD compatibility data, cargo restraint instructions, loading instruction report, load sheet and operator ground operations procedures. The precise document set is operator-specific.
15. Common errors and examination traps
16. Chapter summary
- Aircraft loading must satisfy total mass, CG, compartment, floor and restraint limitations.
- This course describes lower-deck cargo compartments, containerised cargo, palletised cargo, bulk cargo and cargo-handling systems.
- Containers have individual maximum mass and floor-loading limits; pallets are restrained using compatible nets or strops.
- Bulk cargo is restrained by approved nets and may only be carried in compartments authorised for that loading method.
- PDUs, rollers, guides, stops, locks and tie-down fittings support cargo movement and restraint.
- Linear/running-load limits protect underfloor frames; area-load intensity limits protect floor panels.
- Running load = cargo mass ÷ supporting length.
- Area intensity = cargo mass ÷ contact area.
- Rotating cargo can change both running load and area intensity.
- Approved load spreaders can distribute concentrated loads but do not increase aircraft structural limits.
- All checks must be made using aircraft-specific approved data and operator procedures.
17. Knowledge check — 40 questions
Select one answer per question, then mark your answers.
Further study
- UK CAA CAP 697 and CAP 698 — public training data sheets for flight planning and performance (caa.co.uk).
Primary course reference
Used for cargo compartments, containerised/palletised/bulk cargo, cargo handling systems, running loads, area-load limitations, UD and concentrated loads, load spreaders and the 900 kg worked example.
Supplementary operational guidance and safety case
Internet image hosts may change or block embedding. Verify all image links and licensing/attribution requirements before public redistribution. If an image does not load, replace it with a licensed image from the original source or an appropriate aircraft/operator reference.